• Title/Summary/Keyword: Tooth model

Search Result 571, Processing Time 0.028 seconds

Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece (치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가)

  • Han, Myung-Chul;Kim, Jung-Kwan;Choi, Myoung-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

Production of Monoclonal Antibodies Specific to FimA of Porphyromonas gingivalis and Their Inhibitory Activity on Bacterial Binding

  • Koh, Eun-Mi;Kim, Ju;Lee, Jin-Yong;Kim, Tae-Geum
    • IMMUNE NETWORK
    • /
    • v.9 no.5
    • /
    • pp.203-207
    • /
    • 2009
  • Background: The FimA of Porphyromonas gingivalis is a crucial pathogenic component of the bacteria and has been implicated as a target for vaccine development against the periodontal diseases. Methods: In this study, the purified fimbriae (FimA subunit polymers) protein was used for immunization in their native form and B hybridoma clones producing antibodies specific to FimA were established. Results: The monoclonal antibodies prepared from selected two clones, designated #123 (IgG2b/ kappa) and #265 (IgG1/kappa), displayed different patterns of binding activity against the cognate antigen. Both antibodies reacted with conformational epitopes expressed by partially dissociated oligomers, but not with monomer as elucidated by Western blot analysis. Ascites fluid containing the monoclonal antibodies showed the inhibitory activity against P. gingivalis to saliva-coated hydroxyapatite beads, an in vitro model for the pellicle-coated tooth surface. Conclusion: These results suggest that the monoclonal antibodies could be used as vaccine material against the periodontal diseases through passive immunization.

An Optimization of Restoration Method at Class V Lesion of a Finite Element Tooth Model (5급 병소가 있는 치아 유한요소 모델의 수복방법 최적화)

  • Kim, Kwang-Hoon;Woo, Sung-Gwan;Son, Kwon;Park, Jeong-Kil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.678-684
    • /
    • 2008
  • A general treatment is to restore abfraction lesions with dental filler materials to reduce stress concentration. A material should be selected from various dental products based on long term experiences of dentist or personal preference concerning filler methods. A quantitative criterion is necessary to make an evaluation of the results as dentists decide treatment methods and dental materials relying on their clinical experiences. The purpose of this study is to find an optimal restoration method and material for noncarious cervical lesions using the finite element method. An objective function was defined to minimize the sum of tension or compression stress. Trial-and-error and approximation were used to find an optimal restoration method. An optimal solution was to fill TetricFlow inside the lesion and Z100 in the remaining region. The most desirable thickness ratio of the two filler materials was 0.125 with trial-and-error and it was similar to the results of approximation, 0.121 and 0.132.

Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis

  • Er, Ozgur;Kilic, Kerem;Esim, Emir;Aslan, Tugrul;Kilinc, Halil Ibrahim;Yildirim, Sahin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.434-439
    • /
    • 2013
  • PURPOSE. The aim of the present study was to evaluate the effects of posts with different morphologies on stress distribution in an endodontically treated mandibular premolar by using finite element models (FEMs). MATERIALS AND METHODS. A mandibular premolar was modeled using the ANSYS software program. Two models were created to represent circular and oval fiber posts in this tooth model. An oblique force of 300 N was applied at an angle of $45^{\circ}$ to the occlusal plane and oriented toward the buccal side. von Mises stress was measured in three regions each for oval and circular fiber posts. RESULTS. FEM analysis showed that the von Mises stress of the circular fiber post (426.81 MPa) was greater than that of the oval fiber post (346.34 MPa). The maximum distribution of von Mises stress was in the luting agent in both groups. Additionally, von Mises stresses accumulated in the coronal third of root dentin, close to the post space in both groups. CONCLUSION. Oval fiber posts are preferable to circular fiber posts in oval-shaped canals given the stress distribution at the postdentin interface.

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

Study on the Static and Dynamic Structural Analysis Procedure of Excavators (굴삭기의 정적/동적 강도 해석법에 대한 연구)

  • Choung, Joon-Mo;Kim, Gyu-Sung;Jang, Young-Sik;Choe, Ick-Hung;Heo, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.537-543
    • /
    • 2003
  • This paper presents the improved procedure to assess static and dynamic strength of crawler type excavators. A fully integrated model including front attachment and chassis was prepared for structural analysis. In this paper, two types of loading input methods were investigated and the method imposing digging force directly on bucket tooth was more convenient than imposing cylinder reaction force on cylinder pin even if the two methods showed no discrepancy in analysis results. Static strength analysis was carried out for eight analysis scenarios based on two extreme digging positions, maximum digging reach position and maximum digging force positions. The results from static strength analysis were compared with measured stresses, cylinder pressures and digging forces and showed a good quantitative agreement with measured data. Dynamic strength analysis was carried out for simple reciprocation of boom cylinders. It was recognized that the effect of compressive stiffness of hydraulic oil was very important for dynamic structural behavior. The results from dynamic strength analysis including hydraulic oil stiffness were also compared with measured acceleration data and showed a qualitative agreement with measured data.

  • PDF

Nonlinear Diffusion and Structure Tensor Based Segmentation of Valid Measurement Region from Interference Fringe Patterns on Gear Systems

  • Wang, Xian;Fang, Suping;Zhu, Xindong;Ji, Jing;Yang, Pengcheng;Komori, Masaharu;Kubo, Aizoh
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • The extraction of the valid measurement region from the interference fringe pattern is a significant step when measuring gear tooth flank form deviation with grazing incidence interferometry, which will affect the measurement accuracy. In order to overcome the drawback of the conventionally used method in which the object image pattern must be captured, an improved segmentation approach is proposed in this paper. The interference fringe patterns feature, which is smoothed by the nonlinear diffusion, would be extracted by the structure tensor first. And then they are incorporated into the vector-valued Chan-Vese model to extract the valid measurement region. This method is verified in a variety of interference fringe patterns, and the segmentation results show its feasibility and accuracy.

Time Domain Analysis of Ship Motion in Waves Using Finite Element Method (유한요소법을 이용한 파랑 중 선박운동의 시간영역 해석기법 개발)

  • Nam, Bo-Woo;Sung, Hong-Gun;Hong, Sa-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.16-23
    • /
    • 2009
  • The three-dimensional ship motion with forward speed was solved by a finite element method in the time domain. A boundary value problem was described in the frame of a fixed-body reference, and the problem was formulated according to Double-Body and Neumann-Kelvin linearizations. Laplace's equation with boundary conditions was solved by a classical finite element method based on the weak formulation. Chebyshev filtering was used to get rid of an unwanted saw-tooth wave and a wave damping zone was adopted to impose a numerical radiation condition. The time marching of the free surface was performed by the 4th order Adams-Bashforth-Moulton method. Wigley I and Wigely III models were considered for numerical validation. The hydrodynamic coefficients and wave exciting forces were validated by a comparison with experimental data and the numerical results of the Wigley I. The effects of the linearization are also discussed. The motion RAO was also checked with a Wigley III model through mono-chromatic and multi-chromatic regular waves.

A STUDY OF THE CROWN ANGULATION IN NORMAL OCCLUSION (정상교합자의 crown angulation에 관한 연구)

  • Yoon, Jung-Jin;Sohn, Byung-Wha
    • The korean journal of orthodontics
    • /
    • v.16 no.2
    • /
    • pp.123-133
    • /
    • 1986
  • The purpose of this study was to collect the information of the straight-wire appliance and to determine the amount of second-order bends in clinical orthodontics. The author analysed the study model of 50 individuals with normal occlusion and results were obtained as follows. 1. The crown angulation was 4 degree in upper central incisor, 7 degree in upper lateral incisor, and 0 degree in lower central incisor and lateral incisor. 2. The crown angulation was 8 degree in upper cuspid and 2 degree in lower cuspid. 3. The crown angulations were 4 degree in upper first bicuspid, upper second bicuspid and lower second bicuspid and 1 degree in lower first bicuspid. 4. The crown angulation was 3 degree in upper first molar, 0 degree in upper second molar, 5 degree in lower first molar and 8 degree in lower second molar. 5. The crown angulations in lower arch were progressively increased from first premolar to second molar. 6. In upper arch, as the crown angulation of one tooth was increased, those of adjacent teeth were increased, too. 7. In the case of lower arch, the crown angulation of cuspid was increased as that of lateral incisor was increased, the crown angulation of second premolar was increased as that of first premolar was increased, and similarity the crown angulation of second molar was increased as that of first molar was increased.

  • PDF

Autonomic and Skeletal Muscle Response to Non-electrical Cutaneous Stimulation (비 전기적 자극에 대한 자율신경계통과 골격근의 반응)

  • Kim, In-Hyun
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.307-313
    • /
    • 1994
  • Cutaneous stimulation has had a long history as a method of pain control. While there is general agreement that modern techniques such as electrical stimulation and massage often provide relief from acute pain and may in some cases significantly affect chronic pain, the mechanism by which these techniques affect pain remain unclear. Significant attention has been focused on the effects of stimulation on the autonomic nervous system(ANS) along with the increasing evidence of important ANS modulation of nociceptive activity throughout the pain pathway. However, inconsistent results on the presence and direction of ANS changes from cutaneous stimulation characterize the recent literature. The present study investigated a non-electrical cutaneous stimulation device, the Dermapoints massage roller, as well as an active placebo massage. The results indicate that the Dermapoints massage roller has both general effects associated with simple skin stimulation (such as increased skin temperature), as well as specific effects from increased stimulation by the tooth design of the roller. These specific effects include decreased muscle tension (at least for some muscle sites) and increased sympathetic activation. The results are consistent with a model of activation of Pacinian receptors as a possible mechanism for the antinociceptive properties of cutaneous stimulation.

  • PDF