• Title/Summary/Keyword: Tone noise

Search Result 238, Processing Time 0.024 seconds

Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.

Low frequency critical bandwidths of Korean normal hearing adults (한국 정상 성인의 저주파수 임계 주파수 대역 특성에 관한 연구)

  • Moon, Jihyun;Jeon, Kyongeon;Lim, Dukhwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.70-75
    • /
    • 2022
  • The critical bandwidth represents response interactions with respect to a signal tone and their neighboring bands. This study was to analyze the critical bandwidths of a clinically important 500 Hz tone in Korean young male and female subjects (male = 10, female = 10) at a conversational level (60 dB HL). Data were measured with notched band noise and two alternative forced choice methods. Results showed that the critical bandwidth was slightly greater (95 Hz) than the previous Western measures. There were no statistically significant differences in gender, nor were there any significant differences in lateralization of the ear (p > 0.05). These results may have implications in optimizing effective tinnitus masking or the related clinical applications.

A Study on the Performance Noncoherent FH/FSK Including Multitone Jamming (멀티톤 재밍을 고려한 비동기 FH/FSK 성능 분석에 관한 연구)

  • Ahn, Jung-Soo;Park, Jin-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.10
    • /
    • pp.1-9
    • /
    • 1990
  • The performance of noncoherent FH/FSK system in the presence of multitone jamming and noise is analyged. Random and the structured jammings are considered as a multitone jamming model. The probability density function is derived and then optimum decision rule is applied to determine error probability of each cases. As a result, error probabilities of random and structured multitone jamming are shown as a function of number of jamming tones, jamming to signal power ratio, jamming signal phase and one jamming tone power to signal power ratio under Worst-case Jamming interference. It is found that error probability is maximam when one jamming tone power to signal power ratio is 1. Also we know that error performance of random and structured jamming is almost equal.

  • PDF

Study on Supersonic Jet Noise Reduction Using a Mesh Screen (메쉬 스크린을 이용한 초음속 제트소음 저감법에 관한 실험적 연구)

  • Kweon, Yong-Hun;Lim, Chae-Min;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.377-381
    • /
    • 2006
  • This paper describes experimental work to control supersonic jet noise using a mesh screen that is placed at the nozzle exit plane. The mesh screen is a wire-gauze screen that is made of long stainless wires with a very small diameter. The nozzle pressure ratio is varied to obtain the supersonic jets which are operated in a wide range of over-expanded to moderately under-expanded jets. In order to perturb mainly the initial jet shear layer, the hole is perforated in the central part of the mesh screen. The hole size is varied to investigate the noise control effectiveness of the mesh screen. A schlieren optical system is used to visualize the flow fields of supersonic jet with and without the mesh screen device. Acoustic measurement is performed to obtain the OASPL and noise spectra. The results obtained show that the present mesh screen device leads to a substantial suppression of jet screech tones. The hole size is an important factor in reducing the supersonic jet noise. For over-expanded jets, the noise control effectiveness of the mesh screen appears more significant, compared to correctly and under-expanded jets

  • PDF

Noise source localization using comparison between candidate signal and beamformer output in time domain (시간 영역의 빔출력과 후보 신호 사이의 비교를 통한 소음원의 위치 추정)

  • Kim, Koo-Hwan;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.543-543
    • /
    • 2010
  • The objective of this research is estimating the location of interested sound source by using the similarity between a beamformer output in time domain and the candidate signal. The waveform of beamformer output at the location of sound source is similar with the waveform emitted by that source. To estimate the location of sound source by using this feature, we define quantified similarity between candidate signal and beamformer output. The candidate signal describes the signal which is generated by interested source. In this paper, similarity is defined by four methods. The two methods use time vector comparison, and the other two methods use time-frequency map or linear prediction coefficients. To figure out the results and performance of localization by using similarities, we demonstrate two conditions. The one is when two pure tone sources exist and the other condition is when several bird sounds exist. As a consequence, inner product with two time-vectors and structural similarity with spectrograms can estimate the locations of interest sound source.

  • PDF

Performance Analysis of S-DMT for Cable Modem Upstram Channel (케이블 모뎀 상향 채널을 위한 S-DMT의 성능 비교 분석)

  • Kim, Hyung-Jik;Kim, Seong-Jun;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.4B
    • /
    • pp.257-269
    • /
    • 2003
  • S(Synchrous)-DMT(Discrete Multi Tone) is an emerging cable modem technology applicable to the upstream channel for high speed multimedia communication. In this paper we analyze the transmitting and receiving process of S-DMT scheme and derive bit error probability of S-DMT scheme in the $\varepsilon$-mixture impulse noise model which appropriately reflects impulse noise model which approproately reflects impulse noise characteristics of upstream channel. The analysis results show a good match with the simulation results. We also compare Eb/No gain performance of S-DMT with TDMA in 16-, 32-, 64-QAM.

Pair Correlation Analysis of Reaction-Diffusion Halftoning (반응-확산 하프토닝의 공간영역신호 분석)

  • Jho, Chueng-woon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.648-653
    • /
    • 2018
  • Analysis of a specific wavelength band of a video signal is an old research field. However, studies on the analysis of signals having the characteristics of a specific wavelength band or the generation of samples have been conducted actively in recent years. In this paper, we analyze the signal of digital halftoned image. The interpretation of halftoning in terms of signals was first made by Ulichney. We have come to the view that the signal characteristics between pixels used for half toning are good for blue noise. Lau has developed a halftoning method that uses green-noise characteristics by using output-dependent feedback as an error diffusion method. Jho has developed a method for producing halftoned images using a reaction diffusion model. In this paper, we analyze reaction diffusion halftoning in terms of signal to show green noise and compare it with existing green noise half tone.

Changes of Temporal Processing and Hearing in Noise after Use of a Monoaural Hearing Aid in Patients with Sensorineural Hearing Loss: A Preliminary Study

  • Kim, Yehree;Yang, Chan Joo;Yoo, Myung Hoon;Song, Chan Il;Chung, Jong Woo
    • Journal of Audiology & Otology
    • /
    • v.25 no.3
    • /
    • pp.146-151
    • /
    • 2021
  • Background and Objectives: The relationship between hearing aid (HA) use and improvement in cognitive function is not fully known. This study aimed to determine whether HAs could recover temporal resolution or hearing in noise functions. Materials and Methods: We designed a prospective study with two groups: HA users and controls. Patients older than 45 years, with a pure tone average threshold of worse than 40 dB and a speech discrimination score better than 60% in both ears were eligible. Central auditory processing tests and hearing in noise tests (HINTs) were evaluated at the beginning of the study and 1, 3, 6, and 12 months after the use of a monaural HA in the HA group compared to the control group. The changes in the evaluation parameters were statistically analyzed using the linear mixed model. Results: A total of 26 participants (13 in the HA and 13 in the control group) were included in this study. The frequency (p<0.01) and duration test (p=0.02) scores showed significant improvements in the HA group after 1 year, while the HINT scores showed no significant change. Conclusions: After using an HA for one year, patients performed better on temporal resolution tests. No improvement was documented with regard to hearing in noise.

Changes of Temporal Processing and Hearing in Noise after Use of a Monoaural Hearing Aid in Patients with Sensorineural Hearing Loss: A Preliminary Study

  • Kim, Yehree;Yang, Chan Joo;Yoo, Myung Hoon;Song, Chan Il;Chung, Jong Woo
    • Korean Journal of Audiology
    • /
    • v.25 no.3
    • /
    • pp.146-151
    • /
    • 2021
  • Background and Objectives: The relationship between hearing aid (HA) use and improvement in cognitive function is not fully known. This study aimed to determine whether HAs could recover temporal resolution or hearing in noise functions. Materials and Methods: We designed a prospective study with two groups: HA users and controls. Patients older than 45 years, with a pure tone average threshold of worse than 40 dB and a speech discrimination score better than 60% in both ears were eligible. Central auditory processing tests and hearing in noise tests (HINTs) were evaluated at the beginning of the study and 1, 3, 6, and 12 months after the use of a monaural HA in the HA group compared to the control group. The changes in the evaluation parameters were statistically analyzed using the linear mixed model. Results: A total of 26 participants (13 in the HA and 13 in the control group) were included in this study. The frequency (p<0.01) and duration test (p=0.02) scores showed significant improvements in the HA group after 1 year, while the HINT scores showed no significant change. Conclusions: After using an HA for one year, patients performed better on temporal resolution tests. No improvement was documented with regard to hearing in noise.

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF