• Title/Summary/Keyword: Tissue optics

Search Result 56, Processing Time 0.033 seconds

Multi-spectral Mueller Matrix Imaging for Wheat Stripe Rust

  • Yang Feng;Tianyu He;Wenyi Ren;Dan Wu;Rui Zhang;Yingge Xie
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.192-200
    • /
    • 2024
  • Wheat stripe rust, caused by Puccinia striiformis, has reduced winter wheat yield globally for ages. In this work, multi-spectral Mueller matrix imaging with 37 measurements using the method of double rotatable quarter-wave plates was used to investigate wheat stripe rust. Individual Mueller matrix measurements were performed on incident monochromatic light with nine bands in the range of 430 to 690 nm. As a result, it was found that the infected area absorbed linearly polarized light and was sensitive to circularly polarized light in the spectral domain. Both linear depolarization and linear diattenuation images distinguished between wheat stripe rust and healthy tissue. The responsiveness of stripe rust to polarized light reveals the potential of using polarization imaging to detect plant diseases. This further suggests that the multi-spectral Mueller matrix imaging system provides us with an alternative approach to agricultural disease detection.

A Multi-detection Fluorescence Dye with 5-ALA and ICG Using Modified Light Emitting Diodes

  • Yoon, Kicheol;Kim, Eunji;Kim, Kwanggi;Lee, Seunghoon;Yoo, Heon
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.256-262
    • /
    • 2019
  • Extensive tumor resection accompanied by radiotherapy and chemotherapy is the standard of care for malignant gliomas. However, there is a significant obstacle to the complete resection of the tumor due to the difficulty of distinguishing tumor and normal brain tissue with a conventional surgical microscope. Recently, multiple studies have shown the possibility of fluorescence-guided surgery in malignant gliomas. The most used fluorescence dyes for brain tumor surgery are 5-aminolevulinic acid (5-ALA) and indocyanine green (ICG). In this paper, a new fluorescence guided operation system, which can detect both 5-ALA and ICG fluorescent images simultaneously, is presented. This operation system consists of light emitting diodes (LEDs) which emits 410 nm and 740 nm wavelengths. We have performed experiments on rats in order to verify the operation of the newly developed operation system. Oral administration and imaging were performed to observe the fluorescence of 5-ALA and ICG fluorescence in rats. When LEDs at wavelengths of 410 nm and 740 nm were irradiated on rats, 628 nm wavelength with a violet fluorescence color and 825 nm wavelength with a red fluorescence color were expressed in 5-ALA and ICG fluorescent material, respectively, thus we were able to distinguish the tumor tissues easily. Previously, due to the poor resolution of the conventional surgical microscope and the fact that the color of the vein is similar to that of the tumor, the tumor resection margin was not easy to observe, thus increasing the likelihood for cancer recurrence. However, when the tumor is observed through the fluorescence guided operation system, it is possible to easily distinguish the color with the naked eye and it can be completely removed. Therefore, it is expected that surgical removal of cancerous tumors will be possible and surgical applications and surgical microscopes for cancer tumor removal surgery will be promising in the future.

Susceptibility to FAS induced apoptosis in mycoplasma contaminated HCE cells (Mycoplasma가 오염된 배양 각막상피 세포의 FAS 유도 세포고사의 민감성)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.79-86
    • /
    • 2007
  • The aim of the present study was to determine mechanisms of corneal epithelial cell apoptosis in vitro following exposure to anti-FAS and anti-FAS ligand antibody and during infection with mycoplasma sp.. A cultured human corneal epithelial(HCE) cell line was treated with anti-FAS antibody or anti-FAS ligand antibody for 2 and 4 days. The original cell line was found to be contaminated by mycoplasma removal agent(MRA) was used to eliminate the bacterium from the cell line. MRA($0.5{\mu}{\ell}$ tissue culture medium) was added to the cell line and incubated for 1 week. The cell line underwent multiple passages in media not contaminating MRA and cells were grown to 50-80% confluency on coverslips and stained using the Hoechst stain provided in the kit to ensure mycoplasma removal. Apoptosis experiments were performed before and after mycoplasma removal. The apoptotic index of anti-FAS and anti-FAS ligand antibody on mycoplasma contaminated cell line was studied using Hoechst 33342 staining and Annexin V-FITC and Propidium Iodide Staining. In conclusion, anti-FAS antibody induces apoptosis in HCE cells in a time and concentration-dependent mechanism. Cell lines contaminated with mycoplasma have an incresed susceptibility to FAS induced apoptosis.

  • PDF

Apoptotic response to various apoptotic inducers on cultured HCE cells (여러 가지 apoptosis 유도 물질의 각막 상피세포에 대한 apoptosis 유도 반응)

  • Kim, Jai-Min;Kim, Soon-Ae;Yoo, Geun-Chang;Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.65-71
    • /
    • 2003
  • The corneal epithelium is constantly being shed. The mechanism of corneal desquamation is not fully understood. Apoptosis, programmed cell death, may play a role. Apoptosis can be induced by a number of factors and different mechanisms. The study was performed to examine the apoptotic index induced in human corneal epithelial cells maintained in tissue culture by various apoptotic inducers. Various inducers, recombinant human cytokines($INF{\gamma}$, $TNF{\alpha}$, FASAb), actinomycin D. camptothecin, cycloheximide, dexamethasone and etoposide, were purchased from commercial suppliers. Inducers at manufacturer-recommended concentration were added to the corneal epithelial cells for 48 hours. Cell viability was measured using MTT assay. The cells were then assessed for the level of apoptosis. Morphologic changes and quantification of apoptotic cells were determined and counted under fluorescence microscope after inducers-treated human corneal epithelial (HCE) cells for 48 hours with Hoechst 33342 staining. Annexin V-FITC/PI staining and DePsipher assay. The expression of Fas protein was studied by immunocytochemistry. All inducers induced apoptosis in HCE cells in a dose dependent manner. Actinomycin D. camptothecin and etoposide induced apoptosis at lower than manufacturer-recommended concentration, while cytokines, cycloheximide and dexamethasone induced apoptosis at higher concentrations at the end of 48 hours. All inducers elicited typical apoptotic morphologic changes (chromatin condensation, nucleus fragmentations non-orange-red colored mitochondria) and expresses Fas protein highly. Apoptotic index of HCE cells by these inducers was different from the other cell lines. RNA synthesis inhibitor and topoisomerase inhibitors induced apoptosis at lower concentration than manufacturer-recommended concentration. Cytokines, cycloheximide and dexamethasone were able to produce apoptosis at 10 times higher concentrations. RNA synthesis inhibitor and topoisomerase inhibitors are more sensitive than intracellular receptor-activators in apoptotic induction of HCE cells.

  • PDF

Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography (동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험)

  • Kwon, Daa Young;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • Optical coherence elastography (OCE) is based on optical coherence tomography (OCT), which is a noninvasive, high-resolution, cross-sectional imaging technique. In this paper, we have developed dynamic optical coherence elastography to measure elasticity, a mechanical property of tissue, by phase difference. A piezoelectric actuator was used for sinusoidal mechanical loading of samples. Before applying this method to biomaterial, we assessed the feasibility of OCE with samples of sponge, eraser, and sharp lead. Cross-sectional and phase-difference images of the sample were obtained under sinusoidal loading. The strain rate was calculated from the phase-difference information. To obtain the envelope of the phase-difference oscillations along the horizontal direction, Hilbert transformation was performed at each depth. The elevation of the envelope was represented by color mapping, and we could measure the relative elasticity within the sample by comparing the elevations. Finally, there was an advantage when we calculated the shear rate using self-interference in the sample arm, instead of the interference between sample and reference arms.

Endoscopic Spine Surgery

  • Choi, Gun;Pophale, Chetan S;Patel, Bhupesh;Uniyal, Priyank
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.485-497
    • /
    • 2017
  • Surgical treatment of the degenerative disc disease has evolved from traditional open spine surgery to minimally invasive spine surgery including endoscopic spine surgery. Constant improvement in the imaging modality especially with introduction of the magnetic resonance imaging, it is possible to identify culprit degenerated disc segment and again with the discography it is possible to diagnose the pain generator and pathological degenerated disc very precisely and its treatment with minimally invasive approach. With improvements in the optics, high resolution camera, light source, high speed burr, irrigation pump etc, minimally invasive spine surgeries can be performed with various endoscopic techniques for lumbar, cervical and thoracic regions. Advantages of endoscopic spine surgeries are less tissue dissection and muscle trauma, reduced blood loss, less damage to the epidural blood supply and consequent epidural fibrosis and scarring, reduced hospital stay, early functional recovery and improvement in the quality of life & better cosmesis. With precise indication, proper diagnosis and good training, the endoscopic spine surgery can give equally good result as open spine surgery. Initially, endoscopic technique was restricted to the lumbar region but now it also can be used for cervical and thoracic disc herniations. Previously endoscopy was used for disc herniations which were contained without migration but now days it is used for highly up and down migrated disc herniations as well. Use of endoscopic technique in lumbar region was restricted to disc herniations but gradually it is also used for spinal canal stenosis and endoscopic assisted fusion surgeries. Endoscopic spine surgery can play important role in the treatment of adolescent disc herniations especially for the persons who engage in the competitive sports and the athletes where less tissue trauma, cosmesis and early functional recovery is desirable. From simple chemonucleolysis to current day endoscopic procedures the history of minimally invasive spine surgery is interesting. Appropriate indications, clear imaging prior to surgery and preplanning are keys to successful outcome. In this article basic procedures of percutaneous endoscopic lumbar discectomy through transforaminal and interlaminar routes, percutaneous endoscopic cervical discectomy, percutaneous endoscopic posterior cervical foraminotomy and percutaneous endoscopic thoracic discectomy are discussed.

Extracts of Codonopsis lanceolata Decrease $CCl_4$-Induced Hepatotoxicity on High Fat Diet in Rats

  • Han Eun-Gyeong;Lee Yoon-Gyeong;Cho Hyun-Gug
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.447-452
    • /
    • 2004
  • This study was designed to investigate the effect of Codonopsis lanceolata extracts on carbon tetrachloride (CCl₄)­induced hepatotoxicity in rats fed high, medium or low fat diet. The liver weight was increased not by the level of fat in diet but by administration of CCl₄. Activities of serum aspartate aminotransferase (AST) and alkaline phosphatase (ALP) were significantly increased by CCl₄, the activities of AST and alanine aminotransferase (ALT) were significantly decreased in case of CCl₄ treatment with C. lanceolata extracts. In high fat diet with CCl₄ administration, the content of total lipid in liver was significantly increased, which was significantly decreased by the administration of C. lanceolata extracts. Administration of C. lanceolata water extracts remarkably prevented the tissue injury such as lipid degeneration, infiltration of inflanunatory cells and necrosis caused by CCl₄, but those methanol extracts did not affect histopathological changes of the liver as water extract. The data suggest that intake of C. lanceolata extracts would prevent lipid accumulation and hepatotoxicity induced by high fat diet and CCl₄ abministratim, and the water extract of C. lanceolata is supposed to be more effective than those methanol extract.

  • PDF

Cerebral Blood Flow Monitoring by Diffuse Speckle Contrast Analysis during MCAO Surgery in the Rat

  • Yeo, Chaebeom;Kim, Heejaung;Song, Cheol
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.433-439
    • /
    • 2017
  • The rodent model has been used frequently to understand stroke pathophysiology, due to its low cost and the large spectrum of genetic strains available. Here, we present a diffuse speckle contrast analysis system (DSCA) with a $1{\times}2$ optical switch that was used to non-invasively assess cerebral blood flow (CBF) changes in the rat during intraluminal suturing for middle cerebral artery occlusion (MCAO) surgery. The blood flow index (BFI) in the left hemisphere was lower than that in the right hemisphere because the left middle cerebral artery was occluded. Furthermore, the performance of the DSCA system was compared with that of commercial laser Doppler flowmetry. The changes in the BFI measured by the two systems were correlated strongly. The DSCA system was less sensitive to motion artifacts and able to measure relatively deep tissue flow in the rat's brain. In conclusion, the DSCA system secured CBF monitoring during surgery in a rodent model without craniotomy.

Enhancement of Speckle Contrast in vivo by Combining Linearly Polarized Laser Light and an Analyzer

  • Qureshi, Muhammad Mohsin;Mac, Khuong Duy;Kim, Andrew Hyunjin;Kim, Young Ro;Chung, Euiheon
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.351-361
    • /
    • 2021
  • Speckle imaging is capable of dynamic data acquisition at high spatiotemporal resolution, and has played a vital role in the functional study of biological specimens. The presence of various optical scatterers within the tissue causes alteration of speckle contrast. Thus structures like blood vessels can be delineated and quantified. Although laser speckle imaging is frequently used, an optimization process to ensure the maximum speckle contrast has not been available. In this respect, we here report an experimental procedure to optimize speckle contrast via applying different combinations of varying polarization of the illuminating laser light and multiple analyzer angles. Specifically, samples were illuminated by the p-polarization, 45°-polarization, and s-polarization of the incident laser, and speckle images were recorded without and with the analyzer rotated from 0° to 180° (Δ = 30°). Following the baseline imaging of a solid diffuser and a fixed brain sample, laser speckle contrast imaging (LSCI) was successfully performed to visualize in vivo mouse-brain blood flow. For oblique laser illumination, the maximum contrast achieved with p-polarized and s-polarized light was perpendicular to the analyzer's axis. This study demonstrates the optimization process for maximizing the speckle contrast, which can improve blood-flow estimation in vivo.

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.