• Title/Summary/Keyword: Time-efficiency

Search Result 11,910, Processing Time 0.049 seconds

A Study of low cost and high efficiency Solar Cell using SOD(spin on doping) (SOD(Spin On Doping)법을 이용한 저가 고효율 태양전지에 관한 연구)

  • Park, Sung-Hyun;Kim, Kyoung-Hae;Mon, Sang-Il;Kim, Dae-Won;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1054-1056
    • /
    • 2002
  • High temperature Kermal diffusion from $POCl_3$ source usually used for conventional process through put of a cell manufacturing line and potentially reduce cell efficiency through bulk like time degradation. To fabricate high efficiency solar cells with minimal thermal processing, spin-on-doping(SOD) technique can be employed to emitter diffusion of a silicon solar cell. A technique is presented to emitter doping of a mono-crystalline solar cell using spin-on doping (SOD). Moreover it is shown that the sheet resistance variation with RTA temperature and time fer mono-crystalline and multi-crystalline silicon samples. This novel SOD technique was successfully used to produces 11.3% efficiency l04mm by 104mm size mono-crystalline silicon solar cells.

  • PDF

Biological Removal Characteristics by the Internal Recycle Rate in the Attached Growth Process (부착증식공정에서 내부 반송율 변화에 따른 생물학적 제거 특성)

  • 박충기;김병욱;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.110-116
    • /
    • 1999
  • This study was conducted to investigate the contaminants removal efficiency and the optimal operating parameters by the internal recycle rate (IRR) in the combining A2/O process with fixed film. The average removal efficiency of BOD and COD was 92.5%~94.6%, 73.9%~87.0% in RUN 1 and 91.9%~94.7%, 77.7%~89.0% in RUN 2, respectively. Organic removal efficiency, at two different hydraulic retention time of 10 and 14hr, was similar. At 50% of the internal recycle rate, organic removal efficiency was somewhat higher than the other. Total nitrogen (T-N) and total phosphorus (T-P) were removed, highly, at 50% of internal recycle rate. It could be suggested by this study that the optimum internal recycle rate is 50% and hydraulic retention time is 14hr.

  • PDF

Efficiency Enhancement of CFDS Code (CFDS 코드의 효율성 개선)

  • Kim J. G.;Lee J.;Kim C.;Hong S. K.;Lee K. S.;Ahn C. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.123-127
    • /
    • 2005
  • The numerical analyses of the complicated flows are widely attempted in these days. Because of the enormous demanding memory and calculation time, parallel processing is used for these problems. In order to obtain calculation efficiency, it is important to choose proper domain decomposition technique and numerical algorithm. In this research we enhanced the efficiency of the CFDS code developed by ADD, using parallel computation and newly developed numerical algorithms. For the huge amount of data transfer between blocks non-blocking method is used, and newly developed data transfer algorithm is used for non-aligned block interface. Recently developed RoeM scheme is adpoted as a spatial difference method, and AF-ADI and LU-SGS methods are used as a time integration method to enhance the convergence of the code. Analyses of the flows around the ONERA M6 wing and the high angle of attack missile configuration are performed to show the efficiency improvement.

  • PDF

Automatic Measurement of Construction Equipment Efficiency Using a 11-Axis Composite Sensor (11축 복합센서를 통한 건설기계 효율성 측정 자동화 방안)

  • Kwon, Jae-bum;Cho, Dae-gu;Cho, Hun-Hee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.59-60
    • /
    • 2012
  • A large-scale construction project relies much on the efficiency of construction equipment. Therefore, efficient and accurate measurement on the productivity of construction equipment is one of important task in the construction industry. Based on the motivation, this paper proposes a 11-axis composite sensor for an automatic measurement of construction equipment. A 11-axis composite sensor is composed of a gyroscope, geomagnetic and accelerometer sensor for the purpose of real-time motion captures of construction equipment. It is expected that the proposed system can save considerable time, effort and cost of measuring a efficiency of construction equipment.

  • PDF

An Experimental Study on the Solar Collector Efficiency for Apartment Building (공동주택의 태양열 집열기 효율에 대한 실험적 연구)

  • Choi, Byungdo;Kim, Miyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

Theoretical Study for Vehicle Applications of Electrically Heated Catalyst(EHC) (Electrically Heated Catalyst(EHC)의 실차 적용에 관한 이론적 연구)

  • 손건식;이용래;이귀영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.15-26
    • /
    • 1997
  • In this study, the theoretical investigation of the electrically heated catalyst(EHC) for vehicle application has been carried out using the thermal equivalence of EHC system and the data of vehicle tests to meet ultra low emission vehicle(ULEV) standard. To improve the efficiency of EHC system, it is necessary to understand relation between the power, the operating time and the conversion efficiency of EHC system. The relation was found with thermal equivalence of EHC system which considers the power supply to EHC, heat loss, chemical exothermic energy generated by oxidation reaction and net energy coming in via the exhaust gas. From this relation, the limits of needful power and operating time to meet the ULEV standard can be suggested, when the conversion efficiency of catalyst was known.

  • PDF

A Simulation Study on Efficiency of Container Crane in Container Terminal (컨테이너 터미널에서 컨테이너 크레인의 하역능력 추정에 관한 시뮬레이션 연구)

  • Yun, Won-Young;Choi, Yong-Seok;Song, Jin-Young;Yang, Chang-Ho
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.67-78
    • /
    • 2001
  • This paper describes the simulation study which estimates the container crane efficiency in container terminal. In most simulation studies, it is assumed that container cranes are available at any time. Though the failures of container cranes don't occur often, they are very serious problems on terminal efficiency. As usual, the failures of container crane cause arrived ships to delay the departure time. In this study, a queueing simulation model for container terminal, which focuses on the failures of container cranes, is designed. The simulation approach appears to be the most appropriate one because it allows to avoid the usual exponential assumption on interarrivals of ships and service times of container cranes. Using the developed model, we tested the efficiency of container cranes considering failures with a real system size and performed the simulation experiment on real container terminal to validate the developed simulation model. The results of simulation experiment were analyzed using output statistics, which include the waiting times of vessels and yard tractors, the utilization for container cranes, and the berth occupancy rates.

  • PDF

An Energy Saving Cooperative Communications Protocol without Reducing Spectral Efficiency for Wireless Ad Hoc Networks

  • Xuyen, Tran Thi;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2A
    • /
    • pp.107-112
    • /
    • 2009
  • Spectral efficiency of current two-phase cooperative communications protocols is low since in the second time the relay forwards the same signal received from the source to the destination, the source keeps silent in this time. In this paper, we propose a novel cooperative communications protocol where the signal needed to transmit to the destination is sent in both phases, the source and the relay also transmit different signal to the destination thus no loss of spectral efficiency. This protocol performs signal selection based on log-likelihood ratio (LLR) at relay and maximum likelihood (ML) detection at destination. While existing protocols pay for a worse performance than direct transmission in the low SNR regime which is of special interest in ad hoc networks, ours is better over the whole range of SNR. In addition, the proposal takes advantages of bandwidth efficiency, long delay and interference among many terminals in ad hoc network. Simulation results show that the proposed protocol can significantly save total energy for wireless ad hoc networks.

Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.

Analysis of Labelling Efficiency According to Differences of Rotating Time in a Asan Medical Center (AMC) RBC Labelling Method (서울아산병원의 적혈구 표지 방법에서 교반 시간 차이에 따른 표지 효율의 분석)

  • Chung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Shim, Dong-Oh;Lee, Yeong-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.90-93
    • /
    • 2010
  • Purpose: In our nuclear medicine department, we suggested AMC RBC labeling method improved by modifying a part of existing modified in-vitro method to raise the efficiency of $^{99m}Tc$-RBC labeling. However, it needs to be more additional time and efforts than existing modified in-vitro method because the AMC RBC labeling method has to carry out the centrifugal separation process for 3~5 minutes. Therefore, in this study, we conducted researches to aim to maintain stable labeling effects and supplement a problem about additional time by reducing rotating time when labeling $^{99m}Tc$-RBC. Materials and Methods: This research has been conducted the object of 30 patients who examined study using $^{99m}Tc$-RBC and agreed to this research at our hospital from May 2009 to September 2009. We made 4 blood samples which consisted of ACD 1 cc along with 5 cc blood from each patient and used the AMC RBC labeling method. At this moment, each labeling efficiency was calculated by different rotating time 5 min, 10 min, 15 min, and 20 min and then we compared differences. Results: As a result, When comparing the $^{99m}Tc$-RBC labeling method efficiency by using the AMC RBC labeling method which differents from rotating time, each labeling efficiency were $92.3{\pm}5.0%$ in 5 min, $95.9{\pm}5.0%$ in 10 min, $97.4{\pm}4.9%$ in 15 min and $97.7{\pm}4.8%$ in 20 min. We analyzed differences of the labeling efficiency from change of rotating time by using an one-way ANOVA and verified that in Duncan method. There was relatively efficiency low in 5min rotating time and no statistically significant change in over. Conclusions: When comparing a existing method, the AMC RBC labeling method which goes through the centrifugal separation process again offers more favorable condition to combine RBC with $^{99m}TcO4^-$ by eliminating an plasma ingredient. When using the modified in-vitro method, we have almost 20 min to rotate to acquire stable labeling efficiency. But, when using the AMC RBC labeling method, we acquire labeling efficiency well what we want within only 10 min to rotate. Decrease of rotating time can complement the AMC RBC labeling method which goes through the centrifugal separation process again and also provide more rapid study such as G-I bleeding study due to fast labeling.

  • PDF