Abstract
This study was conducted to investigate the contaminants removal efficiency and the optimal operating parameters by the internal recycle rate (IRR) in the combining A2/O process with fixed film. The average removal efficiency of BOD and COD was 92.5%~94.6%, 73.9%~87.0% in RUN 1 and 91.9%~94.7%, 77.7%~89.0% in RUN 2, respectively. Organic removal efficiency, at two different hydraulic retention time of 10 and 14hr, was similar. At 50% of the internal recycle rate, organic removal efficiency was somewhat higher than the other. Total nitrogen (T-N) and total phosphorus (T-P) were removed, highly, at 50% of internal recycle rate. It could be suggested by this study that the optimum internal recycle rate is 50% and hydraulic retention time is 14hr.