• 제목/요약/키워드: Three Cavities

검색결과 240건 처리시간 0.029초

비강 내 공기유동과 열 및 물질전달에 관한 연구 (Research on the nasal airflow and heat and mass transfer)

  • 김성균;휜광림;박준형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1479-1483
    • /
    • 2008
  • The three main physiological functions of nose are air-conditioning, filtering and smelling. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal and deformed nasal cavity models by PIV under both constant and periodic flow conditions. In this time, airflow inside normal nasal cavity is investigated numerically by the FVM general purpose code. The comparisons with PIV measurement are appreciated. Heat and humidity transfer is dealt numerically. Dense CT data and careful treatment of model surface under the ENT doctor’s advice provide more sophisticated cavity models for both PIV experiment and numerical grid system. Average and RMS velocity distributions have been obtained for inspirational and expirational nasal. Temperature distribution, heat and humidity transfer through the mucosa are obtained.

  • PDF

하비갑개 수술 후 비강 모델 내의 세부 유동장의 실험 및 전산 유동가시화 (Experimental and Numerical Flow Visualization on Detailed Flow Field in the Post-surgery Models for the Simulation of the Inferior Turbinectomy)

  • 장지원;허고은;김성균
    • 한국가시화정보학회지
    • /
    • 제9권3호
    • /
    • pp.65-70
    • /
    • 2011
  • Three major physiological functions of nose can be described as air-conditioning, filtering and smelling. Detailed knowledge of airflow characteristics in nasal cavities is essential to understanding of the physiological and pathological aspects of nasal breathing. In our laboratory, a series of experimental investigations have been conducted on the airflows in normal and abnormal nasal cavity models by means of PIV under both constant and periodic flow conditions. In this work, more specifically experimental and numerical results on the surgically modified inferior turbinate model were presented. With the high resolution CT data and a careful treatment of the model surface under the ENT doctor's advice yielded quite sophisticated cavity models for the PIV experiment. Physiological nature of the airflow was discussed in terms of velocity distribution and vortical structure for constant inspirational flow. Since the inferior and middle turbinate are key determinants of nasal airflow, the turbinectomy obviously altered the main stream direction. This phenomenon may cause local changes in physiological function and the flow resistance.

고리 1호기 원자로 공동에서의 방사선 흐름 현상 해석 (Radiation Streaming in KNU-1 Reactor Cavity)

  • Kun-Woo Cho;Chang-Soon Kang
    • Nuclear Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.27-37
    • /
    • 1986
  • 본 논문에서는 고리 1호기의 원자로 압력용기와 1차 콘크리트 차폐체 사이의 인자로 공동에서의 발사선 흐름 현상을 평가하였다. 원자로 압력용기 외부 표면에서 방출되는 누출 선속을 계산하기 위해 사용될 적합한 중성자 단면적 자료를 얻기 위하여, DLC-23/CASK, DLC-31/FEWG그리고 DLC-47/BUGLE 등 세 가지의 중성자 단면적 자료에 대한 검증 계산을 수행하였다. 누출 선속 계산은 ANISN으로 1차원적 계산을, DOT3.5로 2차원적 계산을 수행하였으며, 또한 원자로 공동에서의 방사선 흐름 현상을 분석하기 위하여, 알베도 개념이 도입된 몬테카를로 방법을 사용하는 MORSE-CG 전산 코드를 이용하여 3차원적 해석을 하였다. 그리고, 원자로 플랜지 부위에서의 방사화 분석을 수행하여 스터드 볼트의 방사화 정도를 평가하였다.

  • PDF

구강 보건 교육이 유치원 아동의 구강 건강에 미치는 효과 (The Effect of Oral Health Education on Oral Health in Kindergarten Children)

  • 송병선
    • 대한간호학회지
    • /
    • 제34권1호
    • /
    • pp.132-140
    • /
    • 2004
  • Purpose: This study was performed to investigate the effects of oral health education on kindergarten children. Method: The study was designed as a quasi-experimental, nonequivalent control group pre -post test design. Data was collected from April 1st to November 30th, 2001. The total samples were sixty seven healthy kindergarten children; the experiment group consisted of thirty three and the control group was thirty four children. The experimental group received an oral health education program daily for 20 minutes for four weeks. Result: There was significant improvements on oral health behavior in the experimental group. Streptococcus mutans and lactobacilli of the salivary variables in the experimental group were significantly higher than the control group. The dmft was lower in the experimental group than the control group, but there was no significant difference between the two groups. However it was significantly lower in the experimental group than control group over time. Conclusion: Oral health education for kindergarten children showed an increase in the use of tooth paste and practicing correct tooth brush usage. Also, it decreased the rate of eating cariogenic food and had a positive effect on oral health through suppressing dental cavities.

대학생들의 영어모음 학습 전후의 발화와 지각 (Production and Perception of English Vowels by College Students Before and After Lessons)

  • 양병곤
    • 말소리와 음성과학
    • /
    • 제7권3호
    • /
    • pp.79-88
    • /
    • 2015
  • English vowels are difficult to teach and learn because both teachers and learners cannot show or see shapes of vocal tract inside their own mouth cavities. The aim of this study is to examine what kind of changes occur in production and perception of English vowels by college students before and after lessons in order to provide fundamental materials for teaching students English vowels. Fifteen volunteer female students attending an English phonetics course participated in the lessons for one and half a month period. Formant values of vowels produced and perceived before and after the lessons were obtained using Flying Popcorn and Praat. Results showed that a produced vowel space after the lessons was greater than that before the lessons with no significant difference. Distances between some adjacent corner vowels were too close to be distinguished. Secondly, perceived vowels before and after the lessons were almost the same. Here again, some adjacent vowels were closely spaced. Thirdly, three groups which were divided by the length of the distance between the vowel /i-${\ae}$/ showed similar patterns in their perception and production. Generally the vowel space expanded from [u] to [${\ae}$]. The author concluded that there was no drastic improvement of vowel perception and production within a short period of time. Further studies would be desirable to examine how successful any long-term English vowel lessons would be and which methods should be taken to evaluate students' achievements proposed here.

상온중합(常溫重合) 레진의 혼합시간(混合時間) 차이(差異)에 따른 성묘(成描)의 치수(齒髓反應)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PULPAL RESPONSE TO THE SELP-CURING RESIN FOR THE DIFFERENCE OF MIXING TIMES IN CAT)

  • 이현식;우이형;박남수
    • 대한치과보철학회지
    • /
    • 제27권1호
    • /
    • pp.213-222
    • /
    • 1989
  • It is considered that self-curing resin will induce a little pulpal irritation, if mixing time is insufficient. So this study was designed to compare four different conditions between control group and three experimental groups. Canine teeth of 20 cats used, and class V cavities were prepared on maxillary canine of cats. Control group was filled with zone and other experimental groups were filled with zone after the application of the self-curing resin. Animals of the experimental and control group were sacrified at 3 days, 1, 2, 3, 4 weeks after the experiment. The finding lead to the following conclusions ; 1. Odontoblasts of first and third experimental groups were condensed irregularly and were changed at early stage, and reapir was delayed. 2. Odontoblasts of second experimental group were condensed slightly but, histologic repair was appeared at 4 weeks after the experiment 3. In all groups, the damaged odontoblastic cell layer were eventually disappeared at 4 weeks after the experiment.

  • PDF

컴포머 충전과정에 따른 상아질 투과도의 변화 (DENTIN PERMEABILITY CHANCE ACCORDING TO THE PROCESS OF COMPOMER RESTORATION)

  • 조혜진;이경하;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.382-388
    • /
    • 2002
  • Compomer is composed of matrix and filler : matrix is made of the combination of resins and polycarboxylic molecules that are light-cured, and a filler is a glass component which is capable of ion-release. The resin content of compomers produces polymerization shrinkage which can adversely affect marginal adaptation. Pretreatment is a fundamental step which is treated with conditioner or primer in the use of these materials. Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method, introduced and developed by Pashley's group, has been extensively used for 20 years for research purpose to understand the physiology of dentin, as well as the effects of various restorative treatments on dentin permeability. It permits quantitative, nondestructive measurment of microleakage in a longitudinal manner. The purpose of this study was to evaluate the change of dentin permeability according to the process of compomer restoration. In this study. Cl V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid. The experimental teeth were randomly divided into three groups. Each group was treated with following materials Group 1 : Prime & Bond NT/Dyract AP, Group2: Single Bond/F2000 compomer, Group 3 : Syntac Single Component/Compoglass. The bonding agent and compomer were applied for each group following manufacturers information. Dentin permeability of each group was measured at each process by fluid filtration method; Step 1 : preparation(smear layer). Step 2 : etching(smear layer removal), Step 3 : applying the bonding agent, Step 4 : filling the compomer. Dentin permeability was expressed by hydraulic conductance ($\mu\textrm{l}$ min$^{-1}$cm$H_2O$$^{-1}$). The data were analysed statistically using One-way ANOVA and Sheffe's method. The results were as follows : 1. Dentin permeability differences between each process were significant except between step 1 and step 2(p<0.01). 2. Dentin permeability after removal of smear layer was highly increased(p<0.01). 3. In most case, decrease of dentin permeability was obtained by applying bonding agent(p<0.01). 4. Dentin permeability differences among the experimental groups were not significant(p>0.05). 5. None of compomers used in this study showed perfect seal at the interface.

상아질 접착 지각과민 처치제에 대한 치수반응에 관한 연구 (A STUDY ON THE HUMAN PULPAL RESPONSE TO DENTIN BONDING DESENSITIZER)

  • 유희승;이성복;우이형;박남수;최부병
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.483-495
    • /
    • 1998
  • The purpose of this study was to evaluate the human pulpal response to Dentin Bonding Desensitizer. Class V cavities were prepared on the buccal surfaces of the first premolars and Dentin Bonding Desensitizer(ALL-BOND Desensitizer, Bisco, Inc. U.S.A.) was applicated in ten experimental teeth, or ZOE(PROPAC, GC Co. TOKYO, JAPAN) cement in eight control teeth and cavities were filled with light curing glass ionomer(Fuji II LC, GC Co., TOKYO, JAPAN). At 3-day and 25-day postoperative interval. pulpal response was observed and evaluated histologically with light microscope. The results were as follows. ; 1. At 3-day postoperative interval, the control teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. 2. At 25-day postoperative interval, all control teeth were grade 1 inflammatory cell response and in three control teeth grade 1 connective tissue response were observed, and one teeth showed grade 2 connective tissue response. 3. At 3-day postoperative interval, the experimental teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. Below the cavity, a few inflammatory cell(PMNs) in odontoblastic layer, increased blood vessels and pulpal cells were seen and this pulpal response was similar to control teeth. 4. At 25-day postoperative interval, in four experimental teeth grade 1 inflammatory cell response and grade 1 connective tissue response were observed, and one experimental teeth showed mild inflammatory response. 5. At 3-day and 25-day postoperative interval, no reparative dentin deposition was seen. 6. Both experimental and control group, pulpal response showed difference between 3 and 25-day of postoperative interval. In control teeth, increased predentin and pulpal cells were seen and in experimental teeth, congestion of blood vessels and increased pulpal cells were seen. In conclusion, the pulpal irritation due to this Dentin Bonding Desensitizer was not severe, and it was considered that the agent was not harmful to the human pulp.

  • PDF

시추공 전기비저항 토모그래피를 이용한 비저항 영상화: 과잉취수에 의한 석회암 지반침하 지역 사례 (Resistivity Imaging Using Borehole Electrical Resistivity Tomography: A Case of Land Subsidence in Karst Area Due to the Excessive Groundwater Withdrawal)

  • 송성호;이규상;엄재연;서정진
    • 한국지구과학회지
    • /
    • 제32권6호
    • /
    • pp.537-547
    • /
    • 2011
  • 석회암 공동이 발달한 도심지역에서 지하수위 하강에 수반되어 발생한 함몰형 지반침하의 원인 규명 및 공동의 분포 특성 파악을 위하여 시추공을 이용한 전기비저항 토모그래피탐사를 실시하였다. 이때 지하수 수리지질 특성을 파악하기 위하여 시추코아의 비저항 측정, 지하수위 측정 및 수리전도도 해석을 병행하였다. 연구 지역에서의 완만한 지하수위 분포 특성과 0.8-$9.3{\times}10^{-4}\;cm/s$ 범위의 수리전도도 분포로 부터 연구지역의 수리지질 특성은 불균질성이 크지 않은 것으로 나타났다. 시추코아를 이용한 전기비저항 측정 결과 연구지역의 석회암은 파쇄가 많은 경우, 변질이 심한 경우 및 신선한 경우로 나눠지며, 전기비저항은 각각 103-161, 218-277 및 597-662 ohm-m의 범위로 나타났다. 시추결과 점토로 충전된 석회암 공동 지점은 토모그래피 탐사자료의 역산 결과 50 ohm-m 이하의 낮은 비저항으로 나타났으며, 각 시추공 간 비저항 영상 단면으로부터 연구지역 전체적으로 지표 하부 심도 약 10-20 m 구간까지 파쇄대 또는 석회암 공동 구간이 분포하는 것으로 나타났다. 또한 석회암 공동의 직경은 약 4-6 m 규모로, 대부분 점토질로 충전된 것으로 판단된다.

광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출 (THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH)

  • 정영남;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제29권4호
    • /
    • pp.592-599
    • /
    • 2002
  • 광중합형 복합레진 및 다양한 레진 접착제는 최근 소아의 유치 수복에 사용이 증가하고 있다. 본 연구는 유치의 복합레진 수복 시 중합방법과 접착제에 따른 미세누출의 차이를 실험적으로 관찰하고자 하였다. 탈락기에 있는 건전한 유전치 150개의 순면에 직경 1.6mm, 깊이 1.6mm의 와동을 형성하였다. 와동의 충전재로써 1종의 복합레진, 1종의 콤포머, 4종의 레진 접착제를 사용하였다. 중합 광원은 3종을 사용하였다. 충전이 완료된 각 시편은 Sof-Lex 폴리싱 디스크로 표면을 연마한 후 $5^{\circ}C$$55^{\circ}C$에 각 30초씩 계류시켜 1,000회 열순환하고 2% methylene blue 수용액에 넣어 색소를 침투시킨 후 저속 diamond cutter($Isomet^{TM}$, Buehler, USA)를 이용하여 순면을 근원심으로 절단하였다. 각 재료별 미세누출의 정도를 관찰하여 다음과 같은 결과를 얻었다. 1. 충전재 및 광중합 방법에 따른 미세누출을 측정한 결과, 콤포머를 사용한 5군에서 충전방법과 관계없이 가장 작았고, Clearfil SE bond를 Optilux 501로 중합한 군에서 가장 컸으나 통계적으로 유의한 차이는 아니었다(P>0.05). 2. 충전재에 따른 미세누출을 측정한 결과, 콤포머를 충전한 5군에서 $1{\sim}4$군의 복합레진 충전군에 비해 더 작은 미세누출을 보였다(P<0.05). 3. 광중합 방법에 따른 미세누출을 측정한 결과, Optilux 501을 사용한 군에서 가장 작았고, Flipo를 사용한 군에서 가장 컸으나 통계적으로 유의한 차이는 아니었다(P>0.05).

  • PDF