• 제목/요약/키워드: Three(two)-dimensional images

검색결과 458건 처리시간 0.026초

입체영상(立體映像)을 이용한 원격Robot 조작자의 수행도 분석 (A Performance analysis of robot tele-operator using 3D Images)

  • 조암;전용웅
    • 대한인간공학회지
    • /
    • 제18권3호
    • /
    • pp.127-140
    • /
    • 1999
  • In order to apply three-dimensional images to industries, the possibility of realizing three-dimensional images should be ensured and when operating a task using three-dimensional images, the intention of the observer and the result of operation should be precisely related. The aim of this paper is to investigate the task performance of a human operator during operating a robot manipulator using three-dimensional and two-dimensional image displays. From the result of this research, it was found that the accuracy of robot operation in the case of using three-dimensional displays is much higher than in the case of using two-dimensional displays and the adapting time to the operating task using three-dimensional displays is shorter than that using two-dimensional displays. From such results, we concluded that the application of three-dimensional displays, which can closely reflect real environment, to industries is desirable.

  • PDF

3차원 두부방사선 규격사진 구현시 컴퓨터를 이용한 두부위치의 보정방법에 관한 연구

  • 최광철;김경호;김인달
    • 대한치과의사협회지
    • /
    • 제36권2호통권345호
    • /
    • pp.135-143
    • /
    • 1998
  • Cephalogram is one of the most important tool in researching growth and development of craniofacial area, orthodontic diagnosis and treatment planning. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. three dimensional high quality images can be obtained using computerized tomogram and have reported in literatures. Considering its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. construction of three dimensional image using principle of orientator can be obtained by biplanar stereoradiography. Theoretically two images, lateral and P-A can be used to construct three dimensional image provided that those are taken at same time by two different focal spots. As two images(lateral and P-A) obtained by conventional cephalogram have different head posture, those need compensation to construct three dimensional images. This study introduced principle of computerized head posture compensation and showed that conventional cephalogram could be used to construct three dimensional image and could be applied to routine orthodontic practice.

  • PDF

전산화단층상을 이용한 측두하악관절의 삼차원 재구성상의 비교연구 (A COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF TEMPOROMANDIBULAR JOINT USING COMPUTED TOMOGRAM)

  • 임숙영;고광준
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.335-344
    • /
    • 1993
  • The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joints were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows: 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint spaces were more clearly visualized on dissection images.

  • PDF

입체영상과 평면영상의 심도 인지량에 관한 연구 (Visual depth perception of three dimensinal images and two dimensional images)

  • 조암
    • 대한인간공학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1991
  • This paper aims to examine experimentally the difference of subjectively measured degree of depth between two dimensional (2D) and three dimensional (3D) images. For this paper, two experiments were conducted; in the first experiment, the subjects were asked to estimate the distance between two objects presented with different depths, while in the second experiment, the subjects' role was to rank three objects in the order of distance from the screen. In both experiments, the objects were presented either in 2D or 3D images. The results of the experiments show that the use of 3D images can induce more accurate and more stable estimates of distance than the use of 2D images. However, it is also noted that the absolute degree of depth is not the unique criteria utilized by the subjects for the distinction of small differences of depth.

  • PDF

안전위도(EOG)에 의한 입체영상의 평가 (The estimation of 3D image using EOG)

  • 조암
    • 대한인간공학회지
    • /
    • 제16권1호
    • /
    • pp.1-13
    • /
    • 1997
  • In this research, and investigation of the eye movement was performend when the objects perceived by the eye are three-dimensional objects, two dimensional images, and trhee dimensional images. This investigation was done by observing the EQG(Electro- oculogram) waves which were obtained from experiments. The observed waves were categorized into several groups. Differences among the waves were analyzed for each object and image perceived by the eye. In order to obtain waves for analysis, two kinds of experiments were performen. In each experiment, the saccadic eye movement and the smooth pursuit eye movement were considered as an independent variables. Waves obtained from the experiments were categorized into 4 types (Wave-1, Wave-2, Wave-3, Wave-4) depending on their characteristics. Unlike the other images, three dimensional image was revealed as a key factor for the active movement of the eye. Futhermore, a unique eye movement was observed in the case of three dimensional images where the focus of the eye was achieved through three steps.

  • PDF

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Three Dimensional Segmentation in PCNN

  • Nishi, Naoya;Tanaka, Masaru;Kurita, Takio
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.802-805
    • /
    • 2002
  • In the three-dimensional domain image expressed with two-dimensional slice images, such as fMRI images and multi-slice CT images, we propose the three-dimensional domain automatic segmentation for the purpose of extracting region. In this paper, we segmented each domain from the fMRI images of the head of people and monkey. We used the neural network "Pulse-Coupled Neural Network" which is one of the models of visual cortex of the brain based on the knowledge from neurophysiology as the technique. By using this technique, we can segment the region without any learning. Then, we reported the result of division of each domain and extraction to the fMRI slice images of human's head using "three-dimensional Pulse-Coupled Neural Network" which is arranged and created the neuron in the shape of a three-dimensional lattice.

  • PDF

Integral-floating Display with 360 Degree Horizontal Viewing Angle

  • Erdenebat, Munkh-Uchral;Baasantseren, Ganbat;Kim, Nam;Kwon, Ki-Chul;Byeon, Jina;Yoo, Kwan-Hee;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.365-371
    • /
    • 2012
  • A three-dimensional integral-floating display with 360 degree horizontal viewing angle is proposed. A lens array integrates two-dimensional elemental images projected by a digital micro-mirror device, reconstructing three-dimensional images. The three-dimensional images are then relayed to a mirror via double floating lenses. The mirror rotates in synchronization with the digital micro-mirror device to direct the relayed three-dimensional images to corresponding horizontal directions. By combining integral imaging and the rotating mirror scheme, the proposed method displays full-parallax three-dimensional images with 360 degree horizontal viewing angle.

양 방향 홀로그래피를 이용한 분무 특성 해석 시스템 (Two-Side Holography System for the Measurements of Spray Characteristics)

  • 추연준;강보선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1755-1760
    • /
    • 2004
  • The holographic velocimetry system has a significant potential for the measurements of three dimensional velocities of particles. In this study, orthogonal two-side holography system was developed to obtain three dimensional velocities and sizes of spray droplets. To get high quality of reconstructed images, singe-exposure holography at two time moments and two orthogonal sides was adopted instead of multi-exposure, single-side holography. From three dimensional positions of droplets determined by reconstruction and image processing system, the three dimensional velocities and sizes of each droplet was extracted using the PTV algorithm. To determine the position of particles in the optical axis, a new focusing parameter was introduced based on the correlation between two droplet images at the same distance. The measured results by holography system were compared with those by the PDPA.

  • PDF

안전위도(EOG)에 의한 입체영상의 평가 (The estimation of 3D image using E.O.G)

  • 조암
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1996년도 춘계학술대회논문집
    • /
    • pp.168-185
    • /
    • 1996
  • In this research, an investigation of the eye movement was performed when the objects perceived by the eye are three-dimensional objects, two dimensional images, and three dimensional image. This investigation was done by observing the EOG(Electro-oculogram) waves which were achived from experiments. The observed waves were categorized into several groups. Differences among the waves were analyzed for each object and image perceived by the eye. In order to obtain waves to be analyzed, two kinds of experiments were performed. In each experiments, the saccadic eye movement and the smooth pusuit eye movement was considered as an independent variable individually. Waves obtained from the experiments were categorized into 4 types(Wave1, Wave2, Wave3, Wave4) depending on their characteristics. Unlike from the other images, three dimensional image was revealed as a key factor for the active movement of the eye. Futhermore, a unique eye movement was observed in the case of three dimensional image where the focus of the eye was achived in three steps.

  • PDF