Failure Criterion of Straight Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 직관의 파손 기준)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.76-83
    • /
    • 2014
  • This study was carried out an experimental and finite element analysis on the fracture behavior of straight pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion/corrosion metal loss. The configurations of the eroded area has an eroded ratio of d/t=0.80~0.92 and an eroded length of l=25, 50 and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using the finite element method, which is able to accurately simulate failure behaviors. In regards to the relation ship between pressure and eroded ratio, the criterion that can be used safely under operating pressure and design pressure were obtained from this calculation. The results of this calculation were in relatively good agreement with that of the experiment.

Development of Failure Pressure Evaluation Model for Local Wall-Thinned Elbows Based on Finite Element Analysis (유한요소해석에 기초한 감육곡관 손상압력 평가 모델 개발)

  • Kim, Jin-Weon;Park, Jong-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1063-1071
    • /
    • 2008
  • This paper provides a failure pressure evaluation model for local wall-thinned elbows. In this study, parametric finite element analyses are performed on the elbows containing local wall-thinning defect at their intrados and extrados, and the failure pressures are obtained from the analysis results by applying a local failure criterion that was validated by real-scale pipe tests. An evaluation model including the effects of thinning depth, length, circumferential angle, thinning location, and elbow geometries on the failure pressure is derived based on the evaluated failure pressures. The proposed model agrees well with the results of finite element analyses and reasonably estimates the dependence of failure pressure on the wall-thinning dimensions and elbow geometries. Also, the comparison with experimental data demonstrates that the proposed evaluation model can accurately predict the failure pressure of local wall-thinned elbows.

Fast Thinning Method for Fingerprint Image by Separating End and Bifurcation Regions (단점 및 분기 영역 분리를 이용한 지문영상의 고속 세선화 방법)

  • Lee, Jeong-Hwan;Kim, Jae-Chang
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.10
    • /
    • pp.2816-2822
    • /
    • 1999
  • In this paper, a fast thinning method for fingerprint image by separating end and bifurcation region is proposed. To detect feature points in automatic fingerprint identification system, thinning of fingerprint is essential. The end and bifurcation regions in ridge line are separated by means of run-length coding, and parallel thinning method is applied to the separated regions. The rest parts except the end and bifurcation regions are processed by connecting center points of each run. The performance of the proposed method has been evaluated by CPU processing time and thinness measurement. By the experimental results, the proposed method is fast and has high thinness value.

  • PDF

A Study on Failure Mode of Pipe Elbows with Wall Thinning (두께 감소된 배관 엘보우의 파손 모드에 대한 연구)

  • Shin, Kyu-In;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • Difference of failure modes was studied by finite element analysis for elbows with local wall thinning area particularly at inner surface of intrados of the elbow. Longitudinal wall thinning length, minimum thickness were kept constant but circumferential wall thinning width was varied to get $90^{\circ}$, $180^{\circ}$ and $360^{\circ}$ thinning width. Elastic-plastic analysis were carried out under the combined loading conditions of internal pressure and in-plane bending moment closing the elbow. Von Mises stress were obtained from the outer surface central surface location in intrados, extrados and crown parts in elbow. The results showed that the plastic deformation and failure started from the crown location when the thinning width small ($90{\sim}180^{\circ}$). However, plastic collapse started from the intrados location when the thinning width is approaching $360^{\circ}C$. This should be reflected to assess structural integrity of elbows after wall thinning measurement is made.

  • PDF

The Characteristics of Residual Stand Damages Caused by Skyline Thinning Operations in Mixed Conifer Stands in South Korea

  • Han, Sang-Kyun;Cho, Min-Jae;Baek, Seung-An;Yun, Ju-Ung;Cha, Du-Song
    • Journal of Forest and Environmental Science
    • /
    • v.35 no.3
    • /
    • pp.197-204
    • /
    • 2019
  • A tree-length harvesting system using the HAM300, which is mounted on a farm tractor prototype machine, have been recently introduced in South Korea for thinning old (>30 years) forests. However, no research has previously been conducted on the characteristics of residual stand damage associated with cable yarding systems on thinning treatment stands in South Korea. Therefore, there were assessed on the degree and quantity of residual stand damage caused by felling and yarding process to broaden the knowledge of residual stand damage on semi-mechanized skyline thinning operations. This study investigated scar size, direction, area, shape type and their distribution on the residual stand damage caused by felling and yarding operations. Damage to residual trees was generated for 7.4% and 6.9% of residual trees in felling and yarding operations, respectively. Damaged direction of scars was located in front-side (38.9%) and up-side (34.7%) for felling operations while the highest scar damage was found on down-side (44.6%) for yarding operations. Scar heights of felling damage were higher than those of yarding damage. In yarding operation, the most of the scars was located within l0m from the center of the skyline corridor. These results should be useful information for forest managers and landowners to reduce residual stand damages and retain valuable timber volume from thinning treatments.

Comparative Analysis of Forest Fire Danger Rating on the Forest Characteristics of Thinning Area and Non-thinning Area (숲 가꾸기 실행 및 미 실행지의 임분특성에 따른 산불위험성 비교분석)

  • Lee, Si-Young;Lee, Myung-Woog
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.52-58
    • /
    • 2007
  • The effect of stand-growing-stock characteristics of thinning area and non-thinning area on forest fire was studied in this work. 14 spots were selected from 3 counties such as Yangyang, Injae, and Gapyeong and on-the-spot investigations were performed to evaluate the effect of forest fire. The stand-growing-stock characteristics on the spots were analyzed through the height of tree, breast height diameter, clear length, mortality of branch, forest tree standing crop density, degree of closure, and shrub and grass cover degree. The relation between forest fire and the risk of spread of forest fire were analyzed from the analysis of the stand-growing-stock characteristics. It is considered from this work that the possibility of forest fire is decreased on the thinning area compared to the non-thinning area because of higher clearlength, lower number of tree, lower mortality of branch and higher shrub and grass cover degree.

Introduction and Feasibility on a New Technology for the Pipe Wall Thinning Evaluation of Nuclear Power Plants (원전 배관감육 평가를 위한 새로운 기법의 도입 및 타당성)

  • Hwang, Kyeong Mo;Yun, Hun;Park, Hyun Cheol
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.62-69
    • /
    • 2014
  • A huge number of carbon steel piping components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the piping components. To manage the wall thinning degradation, most of utilities in the world predict the wall thinning rate based on the computational program such as CHECWORKS, COMSY, and BRT-CICERO, evaluate the UT (Ultrasonic Test) data, and determine next inspection timing, repair or replacement, if needed. There are several evaluation methods, such as band, blanket, and strip methods, commonly used for determining the wear of piping components from single UT inspection data. It has been identified that those single UT evaluation methods not only do not consider the manufacturing features of pipes, but also may exclude the data of the most thinned point when determining the representative wear rate of piping components. This paper describes a newly developed single UT evaluation method, E-Cross method, for solving above problems and introduces application examples for several pipes and elbows. It was identified that the E-Cross method using the length and width of UT data excluded the most thinned points appropriate as the single UT evaluation method for thinned piping components.

Anatomical Characteristics and Air-dry Density of Young Trees of Teak Clones Planted in Indonesia

  • Hidayati, Fanny;Ishiguri, Futoshi;Marsoem, Sri Nugroho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.463-470
    • /
    • 2017
  • The objectives of this study are to obtain the basic knowledge of anatomical characteristics and wood properties of thinning trees of young teak (Tectona grandis L.F.) for fulfill the timber demand in Indonesia. Nine thinning trees of 5-year-old teak clone trees were used for analyzing the cell morphology and air-dry density. Vessel diameters in pore and outer pore zones were 165 and $90{\mu}m$, respectively. Mean value of fiber diameter, cell wall thickness, and fiber length in outer pore zone were $14.6{\mu}m$, $2.07{\mu}m$, and 1.04 mm, respectively. In addition, mean value of air-dry density was $0.55g/cm^3$. The measurement and values of vessel diameter, fiber diameter, cell wall thickness, fiber length and air-dry density in the experimental had lower than those in the older teak. Therefore, it could be suggested that the wood from thinning young teaks was not appropriate as construction material, but it could be used for furniture which do not need high of strength properties. Furthermore, since the measurements values of anatomical characteristics were still increasing from pith to bark, it could be suggested that 5-year-old teak clones are still in a juvenile phase. Positively significant correlations were found between air-dry density and cell wall thickness, indicating that cell wall thickness is strongly correlated with wood density of teak.

Failure Behavior of T-joint Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 T-joint 배관의 파손거동)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.80-87
    • /
    • 2014
  • The pipelines are apt to erosion or corrosion because of the high-speed flow of water and steam with high temperatures or high pressures. This study was carried out a finite element analysis (FEA) and an experimental for the fracture behavior of T-joint pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion and corrosion of the metal. The configurations of the eroded area included an eroded ratio of d/t=0.80~0.963 and an eroded length of l=25 mm, 50 mm, and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using FEA, which accurately simulates failure behaviors. In regards to the relationship between pressure and eroded, the criterion that indicates what can be used safely under operating pressure and design pressure were obtained from FEA. The FEA results were in relatively good agreement with that of the experiment.

PLANT ROOT LENGTH DENSITY MEASUTEMENT USING IMAGE PROCESSING

  • Kim, Giyoung;David H.Vaughan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.792-801
    • /
    • 1996
  • A thinning algorithm -based image analysis technique was developed to measure corn root lengths. The root length measurement method was evaluated by comparing thread lengths measured by the image analysis system with actual thread lengths. The length measurement method accurately estimated actual thread lengths (less than 2% calculated error). Also, a rapid root length density measurement procedure, which utilizes the above root length measurement method, was developed to estimate corn root length density without washing the roots. Root length densities estimated from the cut soil surface of core samples taken from the field were paired with the root length densities determined from washed roots from the same soil core sample. A linear relationship between these two values was expected and was found. Eliminating the root washing procedure reduces the time required for measuring corn root length density substantially.

  • PDF