참고문헌
- Chexal, B., Horowitz, J., Dooley, B., Millett, P., Wood, C., and Jones, R., 1998, "Flow-Accelerated Corrosion in Power Plant," EPRI/TR-106611-R2
- Deardorff, A.F. and Bush, S.H., 1990, "Development of ASME Section XI Criteria for Erosion-Corrosion Thinning of Carbon Steel Piping," Proceedings of ASME Pressure Vessels and Piping Conference, PVP-Vol-186, NDE-Vol. 7, pp. 71-75
- Japan Atomic Energy Research Institute, 1993, "Technical Reprt on the Piping Reliability Tests at the Japan Atomic Energy Research Institute (Japanese)," JAERI-M, 93-074, pp. 104-115
- Wilkowski, G., Stephens, D., Krishnaswamy, P., Leis, B., and Rudland, D., 2000, "Progress in Development of Acceptance Criteria for Local Thinned Areas in Pipe and Piping Components," Nucl. Eng. & Des., Vol. 195, pp. 149-169 https://doi.org/10.1016/S0029-5493(99)00245-9
- American Society of Mechanical Engineer, ASME B&PV Sec.XI, Div.1, ASME Code Case N-597, "Requirement for Analytical Evaluation of Pipe Wall Thinning," 1998ed
- Draft for ASME Sec.XI, App.X, "Analytical Evaluation of Internal or External Wall Thinning in Piping Systems," 2003, rev.8
- Kiefner, J.F. and Vieth P.H., 1988, "New Method Corrects Criterion for Evaluating Corroded Pipe," Oil Gas J, Vol. 32, pp. 56-59
- Leis, N. and Stephens, D.R., 1997, "An Alternative Approach to Assess the Integrity of Corroded Line Pipe. Part I Current Status and II Alternative Criterion," Proc. of 7th Int. Offshore and polar Eng. Conf., Honolulu, USA, May 25-30, pp. 624-641
- Kamaya, M., Suzuki, T., and Meshii, T., 2008, "Normalizing the Influence of Flow Length on Failure Pressure," Nucl. Eng. & Design, Vol. 238, pp. 8-15 https://doi.org/10.1016/j.nucengdes.2007.06.006
- Li, Z., Yinpei, W., Jin, C. and Cengdian, L., 2001, “Evaluation of a local thinned pressurized elbow,” Int. J. Press. Ves. Piping, Vol. 78, pp. 697-703 https://doi.org/10.1016/S0308-0161(01)00125-9
- Kim, J.W, Na, M.G. and Park, C.Y., 2005, "Development of Failure Pressure Evaluation Model for Internally Wall Thinned Piping Components," Trans. KSME (A), Vol. 29, pp. 947-954 https://doi.org/10.3795/KSME-A.2005.29.7.947
- Kim, J.W, Na, Y.S, Lee, S.H., and Park, C.Y., 2007, "Evaluation of Failure Pressure of Locally Wall-Thinned Elbow by Real Scale Pipe Tests," ASME PVP-2007, PVP-93444
- ABAQUS Users manual, version 6.8, Hibbitt, Karlson & Sorensen, 2007
- Kim, J.W., Kim, D.H., Park, C.Y. and Lee, S.H., 2007, "Development of Local Failure Criteria for Wall Thinning Defect by Simulated Specimen Tests," Trans. of KSME (A), Vol. 31, No. 3, pp. 304-312 https://doi.org/10.3795/KSME-A.2007.31.3.304
- Park, J.S., Na, Y.S., Kim, J.W., Lee, S.H., 2007, “Validation of a Local Failure Criterion using Results of Failure Test on the Wall-Thinned Elbows,” Proc. of KSME Spring Meeting for Material and Fracture, pp. 123-128
- Miller, A.G., 1988, "Review of Limit Loads of Structures Containing Defects," Int. J. of Press. & Piping, Vol. 32, pp. 197-327 https://doi.org/10.1016/0308-0161(88)90073-7