• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.036 seconds

Estimation of Fluid-elastic Instability Characteristics on Group Plugged KSNP Steam Generator Tube (집단 관막음된 한국표준원전 증기발생기 전열관의 유체탄성불안정성 특성 평가)

  • 조봉호;유기완;박치용;박수기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.670-676
    • /
    • 2003
  • To investigate the group plugging effect the fluid-elastic instability analysis has been performed on various column and row number of the KSNP steam generator lutes. This study compares the stability ratio of the plugged tube with that of the intact one. The information on the thermal-hydraulic data of the steam generator have been obtained by using the ATHOS3-MOD1 code with and without the thermal energy transfer at the plugged region. Both of the boundary conditions of hot-leg temperature and feedwater mass flow rate are fixed for this investigation. From the results of this study the stability ratios inside the group plugging zone are decreased slightly. At the outside of group plugging zone, however, most of the stability ratios tend to be increased.

  • PDF

Numerical analysis for the optimum design of a triple-glazed airflow window (환기식 3중 집열창의 최적설계를 위한 수치해석 연구)

  • Kim, H.J.;Hwang, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF

A Study on the Structural Characteristics of PLZT Thin Films with Zr/Ti Ratios Prepared by Sol-Gel Method (Sol-Gel 법으로 제작된 PLZT 박막의 Zr/Ti 비에 따른 구조 특성에 관한 연구)

  • ;;J. Dougherty
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.7
    • /
    • pp.535-540
    • /
    • 1998
  • Thin films of PLZT were prepared on indium tin oxide(ITO) coated glass substrates by sol-gel process and annealed by rapid thermal annealing(RTA) at $750^{\circ}C$ for 5 minutes. The crystal structure of PLZT thin films were investigated for a different Zr mol% content. XRD results showed that the crystallographic structure was transitted from tetragonal to rhombohedral structure as Zr mol% increased. Raman spectroscopy results showed that the bands of spectra became broader as the amount of Zr mol% increased and two crystal phase coexisted at 2/55/45 PLZT film. Raman spectroscopy was useful for crystal structure analysis of PLZT thin films.

  • PDF

Numerical Study on the Hot Spots of Friction Surface in Disk Brakes (디스크 브레이크 마찰표면의 적열점에 관한 수치적 연구)

  • Kim, Chung-Kyun;Cho, Seung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1692-1696
    • /
    • 2004
  • This paper presents the thermally induced hot spot characteristics of rubbing surface in the friction pad disk brake. During the braking period, the rubbing surface with irregular asperities that are strongly engaged in rough surface, wear, and deformed surface due to a friction heating may produce an irregular distorted geometry of the disk surface. The tribological interactions between the disk and the pads are unstable if the contact stress is severe, in which the irregularity develops the contact pressure distribution, leading eventually to localized contact, high temperature and formation of hot spots. The computed results of contact spots that are simulated using a coupled thermal-mechanical analysis present sinusoidal distortions and localized extrusions of the disk surface, which are strongly related to a hot spot in the practical disk brake.

Thermal Characteristics of an Electric Clothes Dryer (의류건조기의 열적 특성에 관한 실험)

  • Kim, Jun-Ho;Jang, Seok-Pil;Choi, Chul-Jin;Hwang, Kyo-Sik;Lee, Ho-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.629-634
    • /
    • 2009
  • In this paper, drying mechanism is analyzed for improving the energy efficiency of an electric clothes dryer which consumes more electric power than other appliances. For the purpose, characteristic curves of the dryer such as temperature, relative humidity, evaporation rate, mass transfer coefficient, remaining moisture content curves are experimentally obtained. Based on the experimental results and analysis of drying mechanism, the effect of power of a heater and heat loss on the power consumption of an electric clothes dryer are systematically presented. These results demonstrate the feasibility of controlling heat loss at the heater as well as the backduct component to decrease the power consumption of an electric clothes dryer.

Thermal Characteristics of an Electric Clothes Dryer (의류건조기의 열적 특성에 관한 실험)

  • Kim, Jun-Ho;Jang, Seok-Pil;Choi, Chul-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2262-2267
    • /
    • 2008
  • In this paper, drying mechanism is analyzed for improving the energy efficiency of an electric clothes dryer which consumes more electric power than other appliances. For the purpose, characteristic curves of the dryer such as temperature, relative humidity, evaporation rate, mass transfer coefficient, remaining moisture content curves are experimentally obtained. Based on the experimental results and analysis of drying mechanism, the effect of power of a heater and heat loss on the power consumption of an electric clothes dryer are systematically presented. These results demonstrate the feasibility of controlling heat loss at the heater as well as backduct component to decrease the power consumption of an electric clothes dryer.

  • PDF

A STUDY ON HEAT TRANSFER THROUGH THE FIN-WICK STRUCTURE MOUNTED IN THE EVAPORATOR FOR A PLATE LOOP HEAT PIPE SYSTEM

  • Nguyen, Xuan Hung;Sung, Byung-Ho;Choi, Jee-Hoon;Yoo, Jung-Hyung;Seo, Min-Whan;Kim, Chul-Ju
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2137-2143
    • /
    • 2008
  • This paper investigates the plate loop heat pipe system with an evaporator mounted with fin-wick structure to dissipate effectively the heat generated by the electronic components. The heat transfer formulation is modeled and predicted through thermal resistance analysis of the fin-wick structure in the evaporator. The experimental approach measures the thermal resistances and the operating characteristics. These results gathered in this investigation have been used to the objective of the information to improve the LHP system design so as to apply as the future cooling devices of the electronic components.

  • PDF

The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel (복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향)

  • Lee, Tae Won;Kim, Ho Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

A Research survey on the fire investigation case study using CFD in foreign country (CFD 기술을 이용한 국외 화재조사에 관한 연구)

  • Kwon, Young Jin;Koo, In Hyuk;Kim, Dong Eun;Seo, Dong Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.25-26
    • /
    • 2013
  • This study aims to investigate cases of using FDS fire investigation performed in a foreign country, use of FDS for the fire investigation to present the plan to clean up the problems and ways to improve future domestic. To be applied to the fire investigation establish the model of fire growth and domestic situation analysis through case studies and examples of this foreign, domestic flammable thermal characteristics data for exterior and interior windows and on the thermal properties of the experimental the purpose is to improve.

  • PDF

The Study on The Magnetic Properties of Amorphous Fe-B-Si-Ge Ribbons (Fe-B-Si-Ge 비정질 리본의 자기적 특성 연구)

  • 민복기
    • Electrical & Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.113-118
    • /
    • 1997
  • For the amorphous F $e_{78}$ $B_{13}$S $i_{9-x}$G $e_{x}$ alloy, thermal analysis and measurements of the magnetic properties were carried out. As the content of Ge increased, the crystallization temperature was decreased and the Curie temperature was increased, and the tendencies were almost linear. The core loss of the amorphous alloy for x=1.7, field annealed at optimized condition, was 0.057 W/kg(l.0T, 60Hz), which was about 30% lower than that of no Ge added amorphous alloy (basic composition). Such a low core loss characteristics was thought to be caused by the lower coercive force and good squareness of B-H loop of the alloy.y.y.

  • PDF