Estimation of Fluid-elastic Instability Characteristics on Group Plugged KSNP Steam Generator Tube

집단 관막음된 한국표준원전 증기발생기 전열관의 유체탄성불안정성 특성 평가

  • 조봉호 (전북대학교 대학원 항공우주공학과) ;
  • 유기완 (전북대학교 기계항공시스템공학) ;
  • 박치용 (한전 전력연구원 원자력연구) ;
  • 박수기 (한국원자력연구소 하나로이용기술개발부)
  • Published : 2003.05.01

Abstract

To investigate the group plugging effect the fluid-elastic instability analysis has been performed on various column and row number of the KSNP steam generator lutes. This study compares the stability ratio of the plugged tube with that of the intact one. The information on the thermal-hydraulic data of the steam generator have been obtained by using the ATHOS3-MOD1 code with and without the thermal energy transfer at the plugged region. Both of the boundary conditions of hot-leg temperature and feedwater mass flow rate are fixed for this investigation. From the results of this study the stability ratios inside the group plugging zone are decreased slightly. At the outside of group plugging zone, however, most of the stability ratios tend to be increased.