• 제목/요약/키워드: The materials for Floor Impact Sound

검색결과 60건 처리시간 0.021초

아파트 슬래브의 진동평가에 관한 연구 (A Study on Vibration Analysis for the Slab of Apartment Building)

  • 박강근;김용태;최영화
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.333-340
    • /
    • 2006
  • In these days the floor vibration is beginning to make its appearance of the environmental dispute in apartment building. Standard floor system are suggested for the settlement of this issue by government. The sound of floor impact sound is needed to secure comfortable quality in housing. Also, it is required an accurate analysis and a proper evaluation for floor vibration. Refine model is necessary for the floor system of housing to analyze accurately the floor vibration. But this refine model is not efficient because it is required so much running time for vibration analysis and it is difficult of modeling of standard floor slab. In this paper, new modeling methods of standard floor slab are proposed for the accurate rigidity evaluation. By using the new modeling method, the accurate vibration response can be obtained and can accurately evaluate the rigidity of standard floor system with resilient materials. Therefore the proposed modeling method is of practical use for vibration analysis of floor system of apartment building.

  • PDF

바닥마감재에 의한 바닥충격음 차음특성 연구 (A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings)

  • 기노갑;권현종;송민정;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.682-686
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound Insulation performance of materials and elements used in building is falling down as they become thicker and lighter. Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. This paper aims to experiment the sound insulation characteristics of floor coverings as their types and to analyse their noise reduction effect.

  • PDF

공동주택 바닥판에 대한 실용적인 진동해석 (Practical Vibration Analysis for the Floor of Dwelling Building)

  • 박강근;김용태;최영화
    • 한국공간구조학회논문집
    • /
    • 제6권1호
    • /
    • pp.65-73
    • /
    • 2006
  • 공동주택의 바닥 슬래브의 합리적인 진동평가를 위하여 보다 정확한 진동해석이 수행되어야 하므로 바닥 슬래브의 시공방법 및 재료에 따라서 상세하게 모델화하여야 한다. 실제 바닥 슬래브의 수치해석에 있어서 매우 상세하게 모델화하여 진동해석을 수행하는 것은 현실적으로 어려우므로 이에 대한 대안으로 본 논문에서 공동주택의 표준바닥 슬래브에 대한 보다 합리적인 수치해석 방법을 제안하였다.

  • PDF

제진재가 삽입된 바닥 구조의 진동특성 (Vibration Characteristics of the Floor Structures inserted with Damping Materials)

  • 정영;유승엽;전진용;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.377-380
    • /
    • 2005
  • Damping materials encompass a broad range of materials, including, but not limits to, pressure sensitive adhesives, epoxies, rubbers, foams, thermoplastics, enamels and mastics. Their common characteristic is that their modulus is represented by a complex quantity, possessing both a stored and dissipative energy component. Loss factor of damping material analyzed more than 2 times than rubber to 1.5 $\sim$ 2.3, could know that Damping layer has excellent attenuation performance in side of vibration reduction. Measurements of vibration using accelerometers by adhesion of Damping layer, square Plate by Separation of Damping layer is less binding of Damping layer, analyzed low loss factor and Natural Frequency by free Vibration of Square Plate.

  • PDF

바닥충격음 완충재의 재하시간에 따른 동적 특성 연구 (A Study on the Dynamic Properties by Loading Time of Floor Impact Noise Insulation Materials)

  • 김흥식;진필화;주시웅;정성원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.942-945
    • /
    • 2005
  • The purpose of this study is to suggest a fundamental data for change of dynamic properties according to the loading time of resilient materials. 18 kinds of resilient materials included 4 representative types were measured at the load time of 24hours and 2hours by the method of Korea standard (KS F 2868) measuring the dynamic stiffness and the loss factor of materials under floating floors. As a result, the dynamic stiffness was increased rapidly in case of expandable polystyrene and rubber materials according to the load time, especially before 2 hours. The loss factor was represented that rubber materials with high elasticity are high, and expandable polystyrene, polyester, poly ethylene materials with low elasticity are low.

  • PDF

완충재 장기처짐과 ISO 20392 대응 연구 (Correspondence Research of Long-term Compressive Creep of Resilient Materials and ISO 20392)

  • 김경우;연준오;양관섭
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1250-1256
    • /
    • 2012
  • Resilient materials are used to reduce the floor impact sound in apartment buildings. Since an on-dol layer is installed in the resilient materials' upper part, thickness deformation can be occur in the resilient material. It is necessary to check a thickness deformation grade for a long period of time. In this research, we measured thickness deformation over 400th day to the resilient materials(EPP, EPS, EVA) which is used in Korea. Although there was a difference according to the kind of measurement test specimens, it became clear that thickness was decreases as to time increased. The thickness deformation grade of ten years after was calculated based on the thickness measurement result. Compare with the calculated result and result of ISO 20392. Larger thickness deformation occurred in the measurement result of these research findings compare with the ISO standard.

온도변화에 따른 바닥충격음 완충재의 동탄성계수 변화 (The dynamic stiffness of resilient materials for floor impact sound according to temperature change)

  • 연준오;구희모;이성찬
    • 한국음향학회지
    • /
    • 제37권5호
    • /
    • pp.338-342
    • /
    • 2018
  • 상하층 간 공동주택의 바닥충격음 문제를 해결하기 위해 국토교통부에서는 바닥충격음 레벨에 영향을 미치는 완충재에 대한 물성 기준도 함께 고시하고 있다. 완충재에 대한 물성 기준중 가열전후 동탄성계수, 손실계수는 특히 바닥충격음과 가장 연관되어 있다. 따라서 본 연구에서는 기준에서 명시하고 있는 $70^{\circ}C$의 온도 조건을 기준으로 $10^{\circ}C$씩 증가시키고 $10^{\circ}C$씩 저감시켜 온도변화에 따른 동탄성계수 및 손실계수에 대하여 변화율을 검토하였다. 총 8가지 종류의 시료에 대하여 동탄성계수 및 손실계수 측정 방법은 펄스 가진법으로 수행되었으며 결과 산출방법은 감쇠 진동 파형을 이용한 시계열 해석법으로 산출하였다.

공동주택 바닥판의 진동해석 및 평가 (Vibration Analysis and Evaluation for the Slab of Housing)

  • 박강근;김용태;최영화;김한철
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.246-255
    • /
    • 2006
  • 현재 공동주택에서 진동 및 소음이 사회문제로 대두되어 바닥판 슬래브가 점차로 두꺼워 지고 있다. 기존의 공동주택은 대부분의 슬래브의 두께가 12-15cm로 지어졌고, 최근에는 18-2lcm로 설계되어 시공되고 있지만 바닥판의 스팬이 길어짐으로 해서 진동문제가 여전히 발생할 수 있는 가능성이 매우 높다. 공동주택의 바닥 슬래브의 합리적인 진동해석 및 평가를 위하여 보다 정확한 진동해석이 수행되어야 하므로 바닥 슬래브의 시공방법 및 재료에 따라서 상세하게 모델화하여야 한다. 실제 바닥 슬래브의 수치해석에 있어서 매우 상세하게 모델화하여 진동해석을 수행하는 것은 현실적으로 어려우므로 이에 대한 대안으로 본 논문에서 아파트의 바닥 슬래브에 대한 보다 합리적인 수치해석 방법을 제안하고자 한다.

  • PDF

1:10 축척 시험동 구조 모형의 바닥충격 진동 전달 (Propagation of floor impact vibration in a 1:10 scale model of a test structure)

  • 이평직;유승엽;김재호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1455-1458
    • /
    • 2007
  • Vibration characteristics of concrete slabs were investigated using a 1:10 scale model and finite element method. A 1:10 scale model of a test building with 150 and 200mm slab thicknesses was made of acrylic materials. Modal test was conducted to investigate mode shape and modal frequencies. Results show that the mode shapes of two slabs with different thickness are similar each other, whereas natural frequency is different. Through modal analysis using FEM, it was revealed that both mode shapes and natural frequencies calculated from the FEM model are similar to those of the scale model measurement. It was also found that natural frequencies increased with increment of the slab thickness.

  • PDF

폴리우레탄 콘크리트 패널의 특성 및 바닥재로의 이용에 관한 연구 (A Study on the Properties of Polyurethance Concrete Panel and Use for a Flooring Material)

  • 조영국;강재홍;소양섭
    • 콘크리트학회지
    • /
    • 제10권1호
    • /
    • pp.171-178
    • /
    • 1998
  • 본 연구는 폴리우레탄 콘크리트 패널의 바닥재로서의 이용 가능성을 검토하기 위하여 수행되었다. 따라서 각종 요구되는 성능에 부합되는 배합을 달리한 폴리우레탄 콘크리트를 제작하여 각종 물성 실험을 실시하였다. 또한 폴리우레탄 콘크리트 패널을 제작하여 직접 현장에서의 시공한 수 바닥충격음 실험을 실시, 그 효과를 평가하였다. 실험결과, 폴리우레탄 콘크리트의 성능과 코스트의 밸런스가 적절하게 확보된 최적배합비를 도출할 수 있었으며, 특히 기존 바닥구조에 비해 공동주택의 층간소음을 어느 정도 줄일 수 있고 동시에 시공공정의 단축과 단열효과로 보다 더 우수한 바닥난방구조를 제안할 수 있다.