• 제목/요약/키워드: Testing procedure

검색결과 878건 처리시간 0.025초

항공기 구조 동특성 해석을 위한 외부 장착 포드의 유한요소모델 구축 절차 (Finite Element Model Building Procedure of an External Mounting Pod for Structural Dynamic Characteristics Analysis of an Aircraft)

  • 이종학;유구현;양성철;정대윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.72-77
    • /
    • 2011
  • In this study, the natural frequencies and mode shape of an external mounting pod were verified using the modal analysis and modal testing technique for a pod mounted on an aircraft. The procedure associated with the FEM building of an external mounted pod to predict the dynamic behavior of aircraft structures is described. The simplified FEM reflecting the results of the modal testing of a pod is built through the optimization, applied to the structural dynamic model of an Aircraft, used to verified the stability of vibration and flutter of an aircraft.

  • PDF

통계적 가설검정으로서의 선별검사절차의 검토 (Review of Screening Procedure as Statistical Hypothesis Testing)

  • 권혁무;이민구;김상부;홍성훈
    • 품질경영학회지
    • /
    • 제26권2호
    • /
    • pp.39-50
    • /
    • 1998
  • A screening procedure, where one or more correlated variables are used for screeing, is reviewed from the point of statistical hypothesis testing. Without assuming a specific probability model for the joint distribution of the performance and screening variables, some principles are provided to establish the best screeing region. A, pp.ication examples are provided for two cases; ⅰ) the case where the performance variable is dichotomous and ⅱ) the case where the performance variable is continuous. In case ⅰ), a normal model is assumed for the conditional distribution of the screening variable given the performance variable. In case ⅱ), the performance and screening variables are assumed to be jointly normally distributed.

  • PDF

레이다 도파관의 작동상태점검법에 관한 연구 (A Studyu on the Waveguide Running Condition Inspection of Radar)

  • 류대근
    • 한국항해학회지
    • /
    • 제5권2호
    • /
    • pp.41-47
    • /
    • 1981
  • Many new radar techniques have appeared on the electronic scene in recent years, such as a variety of automatic computer processing. However, even with the advent of these sophisticated radar techniques, an old problem continues to plague all radars: the problem of transmission line losses. With the higher performance required today, the Waveguide testing and trouble-shooting techniques remain essentially unchanged in principle. This paper dealt with the rf pulse "Time-domain Reflectometry" to inspect radar wave-guide system and compared with the conventional methods. During the investigation, it was verified that the pulsed TDR for wave-guide is superior to the conventional methods; 1. Disassembling is not needed to locate the discontinity points and measure the reflections of trobled points. 2. The results of the data are more precise. 3. The condition of individual component is able to the photographed and recorded permanently. 4. Since rf pulse TDR is based on the well-known basic radar principle, such a test set requires the minimum of training to operate. With the level of transmission line problems, the prospect of increasing complexity of equipment, and no relief in sight, the benifits must be emphasizied to adopt such a testing procedure.procedure.

  • PDF

Chorionic villus sampling

  • Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • 제11권2호
    • /
    • pp.43-48
    • /
    • 2014
  • Chorionic villus sampling has gained importance as a tool for early cytogenetic diagnosis with a shift toward first trimester screening. First trimester screening using nuchal translucency and biomarkers is effective for screening. Chorionic villus sampling generally is performed at 10-12 weeks by either the transcervical or transabdominal approach. There are two methods of analysis; the direct method and the culture method. While the direct method may prevent maternal cell contamination, the culture method may be more representative of the true fetal karyotype. There is a concern for mosaicism which occurs in approximately 1% of cases, and mosaic results require genetic counseling and follow-up amniocentesis or fetal blood sampling. In terms of complications, procedure-related pregnancy loss rates may be the same as those for amniocentesis when undertaken in experienced centers. When the procedure is performed after 9 weeks gestation, the risk of limb reduction is not greater than the risk in the general population. At present, chorionic villus sampling is the gold standard method for early fetal karyotyping; however, we anticipate that improvements in noninvasive prenatal testing methods, such as cell free fetal DNA testing, will reduce the need for invasive procedures in the near future.

Modified information criterion for testing changes in generalized lambda distribution model based on confidence distribution

  • Ratnasingam, Suthakaran;Buzaianu, Elena;Ning, Wei
    • Communications for Statistical Applications and Methods
    • /
    • 제29권3호
    • /
    • pp.301-317
    • /
    • 2022
  • In this paper, we propose a change point detection procedure based on the modified information criterion in a generalized lambda distribution (GLD) model. Simulations are conducted to obtain empirical critical values of the proposed test statistic. We have also conducted simulations to evaluate the performance of the proposed methods comparing to the log-likelihood method in terms of power, coverage probability, and confidence sets. Our results indicate that, under various conditions, the proposed method modified information criterion (MIC) approach shows good finite sample properties. Furthermore, we propose a new goodness-of-fit testing procedure based on the energy distance to evaluate the asymptotic null distribution of our test statistic. Two real data applications are provided to illustrate the use of the proposed method.

Estimation of high-dimensional sparse cross correlation matrix

  • Yin, Cao;Kwangok, Seo;Soohyun, Ahn;Johan, Lim
    • Communications for Statistical Applications and Methods
    • /
    • 제29권6호
    • /
    • pp.655-664
    • /
    • 2022
  • On the motivation by an integrative study of multi-omics data, we are interested in estimating the structure of the sparse cross correlation matrix of two high-dimensional random vectors. We rewrite the problem as a multiple testing problem and propose a new method to estimate the sparse structure of the cross correlation matrix. To do so, we test the correlation coefficients simultaneously and threshold the correlation coefficients by controlling FRD at a predetermined level α. Further, we apply the proposed method and an alternative adaptive thresholding procedure by Cai and Liu (2016) to the integrative analysis of the protein expression data (X) and the mRNA expression data (Y) in TCGA breast cancer cohort. By varying the FDR level α, we show that the new procedure is consistently more efficient in estimating the sparse structure of cross correlation matrix than the alternative one.

Development of a Data Acquisition System for the Testing and Verification of Electrical Power Quality Meters

  • Simic, Milan;Denic, Dragan;Zivanovic, Dragan;Taskovski, Dimitar;Dimcev, Vladimir
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.813-820
    • /
    • 2012
  • This paper presents the development of a software supported acquisition system for metrological verification and testing of the equipment for monitoring and analysis of the basic electrical power quality parameters. The described procedure consists of two functionally connected segments. The first segment involves generation of the reference three-phase voltage signals, including the possibility of simulation of the various power quality disturbances, typical for electrical power distribution networks. The second part of this procedure includes the real-time recording of power quality disturbances in three-phase distribution networks. The procedure is functionally supported by the virtual instrumentation concept, including a software application developed in LabVIEW environment and data acquisition boards NI 6713 and NI 9215A. The software support of this system performs graphical presentation of the previously generated and recorded signal waveforms. A number of the control functions and buttons, implemented on the virtual instrument front panels, are provided to adjust the basic signal acquisition, generation and recording parameters.

Study on dynamic flexural stiffness of CFST members through Bayesian model updating

  • Shang-Jun Chen;Chuan-Chuan Hou
    • Steel and Composite Structures
    • /
    • 제51권6호
    • /
    • pp.697-712
    • /
    • 2024
  • In this paper, the dynamic flexural stiffness of concrete-filled steel tubular (CFST) members is investigated based on vibration modal testing and a Bayesian model updating procedure. To reflect the actual service states of CFST members, a 3-stage modal testing procedure is developed for 6 circular CFST beam-columns, in which the modal parameters of the specimens under varying axial load levels are extracted. In the model updating procedure, a Timoshenko beam element model is first established, in which the influence of shear deformation and rotational inertia are incorporated. Subsequently, a 2-round Bayesian model updating strategy is proposed to calculate the dynamic flexural stiffness of the specimens, which could effectively consider the influence of physical constraints in the updating process and achieve reasonably well results. Analysis of the updating results shows that with the increase of the axial load level, degradation of the flexural stiffness is significantly influenced by the load eccentricity. It shows that the cracking of the core concrete is the primary reason for the flexural stiffness degradation of CFST beam-columns. Finally, based on comparison with equations proposed by several design standards, the calculation methods for the dynamic flexural stiffness of CFST members is recommended.

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • 제31권6호
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.

폼드아스팔트를 이용한 현장 상온 재생 아스팔트 혼합물의 동탄성계수 결정 (Determination of Dynamic Modulus of cold In-place Recycling Mixtures with Foamed Asphalt)

  • 김용주;이호신
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-12
    • /
    • 2009
  • 폼드아스팔트를 이용한 현장 상온 재생아스팔트 혼합물에 대한 배합설계법이 아이오아 주 교통국에서 사용하기 위해 개발되었다. 상온 재생 폼드아스팔트 혼합물의 배합설계를 위한 실내시험절차를 개선하기 위하여 배합설계에 영향을 미치는 중요한 배합설계변수들을 결정하여 상온 재생 폼드아스팔트 혼합물의 특성을 반영할 수 있는 새로운 배합설계절차를 개발하였다. 개발된 배합설계법의 검증을 위한 한 가지 방법으로 상온 재생 폼드아스팔트 혼합물의 동탄성계수를 측정하였다. 본 연구에서는 새로운 simple performance testing 장비를 이용한 상온 재생 폼드아스팔트 혼합물의 동탄성계수 측정을 위한 표준시험절차를 정립하고, 7가지 재생 아스팔트 골재를 사용하여 생산된 상온 재생 폼드아스팔트 혼합물의 동탄성 계수를 측정하여 마스터곡선을 작성하였다. 또한 재생 아스팔트 골재의 특성이 상온 재생 폼드아스팔트혼합물의 동탄성 계수에 미치는 영향을 조사하였다. 3가지 온도와 6가지의 하중주기에서 측정된 상온 재생 폼드아스팔트 혼합물의 동탄성계수는 7가지 재생 아스팔트 골재에서 일관된 값을 나타내었으며, 작성된 상온 재생 폼드아스팔트 혼합물의 마스터곡선은 가열 아스팔트 혼합물의 마스터곡선에 비해 하중주기에 대해 덜 민감한 것으로 평가되었다. 저온에서는 재생 아스팔트 골재의 잔골재 함유량이 상온 재생 폼드아스팔트 혼합물의 동탄성계수에 영향을 미치는 것으로 나타났으며, 고온에서는 재생 아스팔트 골재의 잔류 아스팔트 특성이 상온 재생 폼드아스팔트 혼합물의 동탄성계수에 영향을 미치는 것으로 나타났다.

  • PDF