• Title/Summary/Keyword: Test procedures

Search Result 1,861, Processing Time 0.029 seconds

A Fundamental Study on the Development of Fire Resistance Filling of Friendly Environment Using Aerated Concrete (기포콘크리트를 이용한 친환경 내화충전제개발에 관한 기초적 연구)

  • Lee, jong-il;Lim, Nam-Gi
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.119-126
    • /
    • 2007
  • In this study, we processed two procedures of application test of filler for fire-resistance utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

The Scale Ratio Testing of Multiple Outliers in Linear Regression

  • Park, Jin-Pyo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.3
    • /
    • pp.673-685
    • /
    • 2003
  • In this paper we consider the problem of identifying and testing outliers in linear regression. First we consider the problem for testing the null hypothesis of no outliers. A test based on the ratio of two residual scale estimates is proposed. We show the asymptotic distribution of the test statistics by Monte Carlo simulation and investigate its properties. Next we consider the problem of identifying the outliers. A forward sequential procedure using the suggested test is proposed and shown to perform fairly well. Unlike other forward procedures, the present one is unaffected by masking and swamping effects because the test statistic is based on robust scale estimate.

  • PDF

New Method for Measurement and Validation of In-situ Sound Transmission Loss (In-situ 소음투과손실 측정 및 검증을 위한 기법 개발)

  • Lee, Hwa-Soo;Park, Hong-Cheol;Yoon, Seong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.795-800
    • /
    • 2008
  • The sound transmission loss is a key index to evaluate the acoustic performance of a car-body structure at the high frequency range. From this paper, a new validation method for in-situ sound transmission loss is proposed. First, in-situ sound transmission loss is measured by using PU intensity probe on the condition of complete vehicle. Second, validation test, which is consisted of internal, external and total frequency response function test, is performed by using volume acceleration source and microphones. Then, these test results are compared to validate the accuracy of in-situ sound transmission loss. Finally, the test result of in-site method is compared with results of two reverberant room test method and SEA analytical method. The reliability of in-situ method is confirmed by these procedures.

  • PDF

Development of Load Cell to Measure Contact Force of Pantograph (판토그라프 접촉력 측정을 위한 스트레인 게이지 내장형 센서 개발)

  • Park, Chan-Kyoung;Paik, Jin-Sung;Kim, Young-Guk;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.947-953
    • /
    • 2010
  • The KTX-Sancheon has been commercially operating on the high-speed line since March. 2. In order to verify the performance of high-speed train and core equipments such as current collection system, sophisticated tests and evaluating procedures should have been considering. In this paper, the load cell with a built-in strain-gauge which developed to improve measuring method of contact force between the pantograph and catenary system is introduced. The static test results of the load cell shows that its design is very suitable and applicable for the dynamic test and on-line test. After the test and evaluation of load cell's dynamic calibration with pantograph, we will be applied to test interaction characteristics between the pantograph and catenary system on the high-speed line.

  • PDF

The Forward Sequential Procedure for the Identifying Multiple Outliers in Linear Regression

  • Park, Jin-Pyo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.4
    • /
    • pp.1053-1066
    • /
    • 2005
  • In this paper we consider the problem of identifying and testing outliers in linear regression. First we consider the use of the so-called scale ratio tests for testing the null hypothesis of no outliers. This test is based on the ratio of two residual scale estimates. We show the asymptotic distribution of the test statistics and investigate its properties. Next we consider the problem of identifying the outliers. A forward sequential procedure using the suggested test is proposed. The new method is compared with classical procedure in the real data example. Unlike other forward procedures, the present one is unaffected by masking and swamping effects because the test statistic is based on robust scale estimate.

  • PDF

Study on the Report Conformance Test of IEC 61850 based IED (IEC 61850기반 IED 대상 리포트 적합성 시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, J.H.;Song, I.J.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.241-242
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "The verification of Performance of the Substation Automation System and Its Field Test". This paper presents reporting services of IEC 61850-8-1 and related UCA Test procedures, reporting test items are widely divided into unbuffered report and buffered report and this paper is dealing with unbuffered report.

  • PDF

Development of Standard Procedures for Local Leakage Rate Testing of Containment Vessel (격납건물 국부누설률시험 표준절차 개발)

  • Moon, Yong-Sig;Kim, Chang-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.42-47
    • /
    • 2012
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS 56.8-1994 in Korea. Two methods, the make-up flow rate and the pressure decay, are used for local leakage rate testing. Though ANSI/ANS 56.8-1994 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the testing time is differently applied to each NPPs. Therefore, this study presents a standardized test procedure for data stabilization and testing time through experiments to improve the test reliability.

The microdetection of alkaloids with amberlite IRC-50 (Amberlite IRC-50에 의한 alkaloid의 미량검출법)

  • 김근영;이윤중;손윤자
    • YAKHAK HOEJI
    • /
    • v.11 no.1_2
    • /
    • pp.4-6
    • /
    • 1967
  • Cation exchange resin particles amberlite IRC-50 were used as a medium for a identific test of alkaloids with dragendorff reagent. The procedures were as follows; A few particles of amberlite IRC-50 were added to the small portion of sample solutions on a spot plate or in a test tube. After 20 minutes-an hour, a drop of dragendorff reagent were added to particles of resin that were adsorbed. When alkaloid was present, the original color of the resin particles changed instantly to red or reddish orange depending on the amount and kind of alkaloid, while in the absence of alkaloid the original color of the resin particles changed light yellow. These methods were more sensitive than the ordinary spot test or paper spot test for alkaloid. The limits of identifications of nine alkaloids were tested by these methods and compared with the paper spot test method.

  • PDF

On Testing Exponentiality Against HNRBUE Based on Goodness of Fit

  • Mahmoud, M.A.W.;Diab, L.S.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.27-39
    • /
    • 2007
  • Based on goodness of fit new testing procedures are derived for testing exponentiality against harmonic new renewal better than used in expectation (HNRBUE). For this aging properties, a nonparametric procedure (U-statistic) is proposed. The percentiles of this test statistic are tabulated for sample sizes n=5(1)30(10)50. The Pitman asymptotic efficiency (PAE) of the test is calculated and compared with, the (PAE) of the test for new renewal better than used (NRBU) class of life distribution [see Mahmoud et al (2003)]. The power of this test is also calculated for some commonly used life distributions in reliability. The right censored data case is also studied. Finally, real examples are given to elucidate the use of the proposed test statistic in the reliability analysis.

  • PDF

The Effects of Literature-based Reading Instruction on Children's Literacy (문학작품을 통한 읽기 지도 전략이 초등학교 아동의 문식성에 미치는 효과)

  • Kim, Sun-Deok;Jang, Yeon-Jip
    • Korean Journal of Child Studies
    • /
    • v.21 no.4
    • /
    • pp.243-257
    • /
    • 2000
  • This empirical test of the efficacy of the literature-based reading instruction was conducted with 63(31 male and 32 female) 2nd grade elementary school children. Subjects in the experimental group had 40-45 minutes literature-based reading instruction twice weekly; those in the control group had only basic text reading. Procedures included a pilot study, pre-test, experimental period, and post-test. Research instruments included the Basic Learning Skill Test(Park et al., 1988), the Qualitative Reading Inventory(Leslie & Caldwell, 1990), and the Elementary Reading Attitude Survey(Mckenna & Kear, 1990). Data were graded and scored by each research question and then analyzed with a t-test of differences between the groups. The experimental group showed higher word recognition, text comprehension, and story grammar strategies than the control group. They also showed more improvement in each of these categories than the control group.

  • PDF