• Title/Summary/Keyword: Test and Evaluation(T&E)

Search Result 195, Processing Time 0.028 seconds

A Study on Mission Critical Factors for Software Test Enhancement in Information Technologies Development of Public Sector (Mission Critical 공공 정보화 구축 시험평가 개선 지표 연구)

  • Lee, Byung-hwa;Lim, Sung-ryel
    • Journal of Internet Computing and Services
    • /
    • v.16 no.6
    • /
    • pp.97-107
    • /
    • 2015
  • Up until recently, Korea has ranked the first place in UN e-Government Survey for three consecutive years. In keeping with such accomplishment, the size of budget execution has been consistently growing in accordance with Korea's Government 3.0 policy and vision, leading to increase in big-sized informatization projects in the business. Especially in mission critical public sector's infrastructure where it affects many people, growing demand for establishing high-quality information system with new technologies being brought to attention in order to meet the complex needs of citizens. National defense information system, being one of representative domains examples in the concerned area, established high military competency by applying breakthrough technology. Network-oriented national defense knowledge informatization was set as the vision in order to implement core roles in making efficient national defense management; and effort has been made to materialize the vision by making advancement in national defense's information system and its informatization implementation system. This research studies new quality index relevant to test and evaluation (T&E)of informatization business in national defense which is the representative example of mission critical public sector's infrastructure. We studied international standards and guidelines, analyzed actual T&E cases, and applied them to the inspection items that are currently in use, complying with the e-government law (Act No. 12346, Official Announcement Date 2014. 1.28., Enforcement Date 2014. 7.29.) As a result of productivity analysis, based on hypothesis in which suggested model was applied to T&E of the national defense informatization business, we confirmed the possibility of enhancement in the T&E productivity by assessing reliability, expertise, and safety as evaluation factors.

A Study on the Store Compliance Verification for KT-1P Aircraft

  • Kim, Dae-wook;Kim, Chan-jo;Wu, Bong-gil
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.87-91
    • /
    • 2015
  • KT-1P for the Peru Air Force will be used as a utility aircraft with upgraded avionics equipment and arming capability based on KT-1 and KA-1. KT-1P should be shown for compatibility of new store loading configurations loaded with dispenser, bomb, and rocket based on aircraft-store compatibility test and evaluation procedures before KT-1P is operated as a light attack aircraft. The weapon system ground test for installation and flight test for envelope expansion including store separation are described in this paper, which was performed referring 'seek eagle program' under MIL-HDBK-1763 and MIL-HDBK-244A.

Bioequivalence Evaluation of Senafen Tablet and Airtal Tablet Containing Aceclofenac 100 mg (아세클로페낙(100mg) 제제인 세나펜 정과 에어할 정의 생물학적동등성 평가)

  • 박은우;송우헌;차영주;최영욱
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.423-428
    • /
    • 1998
  • Aceclofenac is an orally effective non-steroidal anti-inflammatory agent of the phenylacetic acid derivative. Bioequivalence study of two aceclofenac preparations, the test drug (Senafe $n_{R}$: Daewon Phar-maceutical Company) and the reference drug (Airta $l_{R}$: Daewoong Pharmaceutical Company), was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Sixteen healthy male volunteers, 24$\pm$4 years old and 63.9$\pm$6.9 kg of body weight in average, were divided randomly into two groups and administered the drug orally at the dose of 100 mg as aceclofenac in a 2$\times$2 crossover study. Plasma concentrations of aceclofenac were monitored by HPLC method for 12 hr after administration. AU $Co_{-12h}$ (area under the plasma concentration-time curve from initial to 12 hr) was calculated by the linear trapezoidal method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{msx}$) were compiled directly from the plasma drug concentration-time data. Student's t-test indicated no significant differences between the formulations in these parameters. Analysis of variance (ANOVA) revealed that there are no differences in AU $Co_{12h}$, $C_{max}$ and $T_{max}$ between the formulations. The apparent differences between the formulations were far less than 20% (e.g., 0.25, 0.01 and 7.32 for AU $Co_{-12h}$, $C_{max}$. and $T_{max}$, respectively). Minimum detectable differences (%) between the formulations at $\alpha$=0.05 and 1-$\beta$=0.8 were less than 20% (e.g., 14.65, 12.47 and 15.46 for AU $Co_{-l2h}$, $C_{max}$ and $T_{max}$, respectively). The 90% confidence intervals for these parameters were also within $\pm$ 20% (e.g.,-10.19~10.68, -8.87~8.89 and -3.69~ 18.33 for AU $Co_{-12h}$, $C_{msx}$ and $T_{max}$, respectively). These results satisfy the bioequivalence criteria of KFDA guidelines, indicating that two formulations of aceclofenac are bioequivalent.quivalent.ivalent.ent.t.ent.

  • PDF

Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility

  • Bae, Byoung-Uhn;Lee, Jae Bong;Park, Yu-Sun;Kim, Jongrok;Kang, Kyoung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2477-2487
    • /
    • 2021
  • To improve safety analysis technology for a nuclear reactor containment considering an interaction between a reactor coolant system (RCS) and containment, this study aims at an experimental investigation on the integrated simulation of the RCS and containment, with an integral effect test facility, ATLAS-CUBE. For a realistic simulation of a pressure and temperature (P/T) transient, the containment simulation vessel was designed to preserve a volumetric scale equivalently to the RCS volume scale of ATLAS. Three test cases for a steam line break (SLB) transient were conducted with variation of the initial condition of the passive heat sink or the steam flow direction. The test results indicated a stratified behavior of the steam-gas mixture in the containment following a high-temperature steam injection in prior to the spray injection. The test case with a reduced heat transfer on the passive heat sink showed a faster increase of the P/T inside the containment. The effect of the steam flow direction was also investigated with respect to a multi-dimensional distribution of the local heat transfer on the passive heat sink. The integral effect test data obtained in this study will contribute to validating the evaluation methodology for mass and energy (M/E) and P/T transient of the containment.

Study on Friction Welding of SUS431 and SCM21 for External Shaft of Ship (선외기 샤프트용 재료의 마찰용접에 관한 연구)

  • 오세규;이종환;배명주;오명석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.38-48
    • /
    • 1993
  • A study on friction welding of stainless steel bar(SUS431) to chrome molybdenum steel bar(SCM21) was accomplished experimentally through analysis for relations among friction welding conditions, tension test, hardness test, microstructure test and acoustic emission test. The results obtained are summarized as follows ; 1. Through friction welding of SUS431 bar to SCM21 bar, the optimum welding condition by considering on strength and toughness was found to be the range of heating time of 3-5 sec when the number of rotating speed of 2000rpm, heating pressure of 10kg/$mm^2$, and upsetting time of 4 sec. 2. Quantitative ralationship was identified between heating time($T_1$, sec) and tensile strength (${\sigma},\;kgf/mm^2$) of the friction welded joint and the relation equation is $\sigma$=52.62$T_1{^{0.06}}$. 3. Through AE test, quantitative relationship was confirmed between heating time($T_1$, sec) and total AE(N, counts) during welding, and the relation is computed as follows ; N=30413.6$e^{0.06T1}$. 4. It was confirmed that the quantitative ralationship exists between the tensile strength of the welded joints and AE cumulative counts. And the relation is computed as the following ; ${\sigma}$=16.37(ln N)- 116.4. 5. When ONZ=36500-41500 counts by $OT_1Z$=3~5sec, it was identified by experiment that the range of welded joint tensile strength is 55.6-57.7kgf/$mm^2$/ whose joint efficiency is more than 100%, and it was experimentally confirmed that the real-time nondestructive quality(strength) evaluation for the friction welded joints could be possible by acoustic emission technique.

  • PDF

Automated data interpretation for practical bridge identification

  • Zhang, J.;Moon, F.L.;Sato, T.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.433-445
    • /
    • 2013
  • Vibration-based structural identification has become an important tool for structural health monitoring and safety evaluation. However, various kinds of uncertainties (e.g., observation noise) involved in the field test data obstruct automation system identification for accurate and fast structural safety evaluation. A practical way including a data preprocessing procedure and a vector backward auto-regressive (VBAR) method has been investigated for practical bridge identification. The data preprocessing procedure serves to improve the data quality, which consists of multi-level uncertainty mitigation techniques. The VBAR method provides a determinative way to automatically distinguish structural modes from extraneous modes arising from uncertainty. Ambient test data of a cantilever beam is investigated to demonstrate how the proposed method automatically interprets vibration data for structural modal estimation. Especially, structural identification of a truss bridge using field test data is also performed to study the effectiveness of the proposed method for real bridge identification.

Loop modeling of VDSL system and performance evaluation of DWMT data transmission (VDSL System의 선로 모델링 및 DWMT 전송방식의 성능평가)

  • 이성재;홍훈희;김문성;곽훈성;최재호
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.853-856
    • /
    • 1999
  • In this paper, for the performance evaluation of the discrete wavelet multitone based VDSL modem we have studied VDSL system test loops(VDSL0 - VDSL7) that are proposed by ANSI T1E1.4. In addition, we have modeled the damage factors of the transmission channel and evaluated the data transmission performance of VDSL transmultiplexer based on DWMT in conjunction with the VDSL test loops. For each M-PAM signaling we have evaluated the SNRs that satisfy BER 〓 10$^{-7}$ through simulation and measured the maximum possible transmission speed on each VDSL test loop.

  • PDF

A Study on the Assessment Contents and Construction of Mathematics in the College Scholastic Ability Test of China (중국 대학입학시험의 수학 평가내용 및 구성 고찰)

  • Jeon, Young-Ju
    • Journal of the Korean School Mathematics Society
    • /
    • v.14 no.1
    • /
    • pp.85-100
    • /
    • 2011
  • A formal name of the college scholastic ability test of China is P$\check{u}$tongg$\bar{a}$od$\check{e}$ngxu$\acute{e}$xi$\grave{a}$o zh$\bar{a}$osh$\bar{e}$ng Qu$\acute{a}$ngu$\acute{o}$ t$\check{o}$ngy$\bar{i}$k$\check{a}$osh$\grave{i}$(普通高等學校初生全國統一考試), abbreviated to Gaokao(高考). Gaokao is very similar to Korea's College Scholastic Ability Test in that the two exams are measuring test-taker's knowledge and ability included in highschool curriculum and that they are the selective examinations which persons with at least a high school diploma or the equivalent apply for. Therefore, helpful implications for College Scholastic Ability Test of Korea can be drawn from the study of assessment contents and construction of mathematics in Gaokao.

  • PDF

A Study on the V&V Process of M&S for the Test and Evaluation (시험평가용 M&S에 대한 V&V 프로세스 연구)

  • Park, Ju-Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.397-404
    • /
    • 2019
  • When developing a weapon system, a T&E(Test and Evaluation) can be performed using M&S for the test items that cannot be evaluated in the real world. In this case, the VV&A activities are required to prove the credibility of M&S for the T&E. Recently, the use of M&S has been increasing as the R&D trends of weapon systems are becoming more advanced. Therefore, the VV&A activities are also increasing. The VV&A activities aim to verify, validate, and accredit that the simulation can represent a real system and ensure credibility regarding its purpose and intention of use. VV&A activities are divided into V&V and Accreditation. When performing VV&A in the ADD (Agency for Defense Development), the V&V activities are performed by a separate department of the ADD and the accreditation activities are performed in the DTAQ (Defense Agency for Technology and Quality). This paper proposes a V&V process for a T&E of M&S that has been performed in ADD. The process is used to verify and validate the documents and data generated during the development process according to the accreditation criteria, and provides objective data that can be used to judge whether the accreditation decision and acceptance criteria are met.

Bioavailability Evaluation of Two Ceftriaxone Formulations Using Two Way Crossover Design in Voluteers

  • Kwon, Kwang-Il;Bok, Soo-Jin;Kim, Moo-Heon;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • v.18 no.4
    • /
    • pp.237-242
    • /
    • 1995
  • For the vioequivalence study of two ceftriaxone injection formulations ($Rocephin{\circledR}$ ; Roche, and Triaxone ; Hanmi0, the HPLC analytical method for the analysis of ceftriaxone in plasma was used. Fourteen healthy volunteers completed the study and each subject were IM in jected signle doses (1 g) of the test and the reference formulations in a two-way crossover design with an one week drug free interval between doses. Following each administration, plasma concentrations of ceftrixone were monitored over a period of 24 h. Bioequivalence parameters $AUC_{24th}, {\;}T_{max}, {\;}C_{max}$ and MRT determined from the data obtained for the two formulations were examined by analyses of variance (ANOVA) and other criteria and tests for bioequivalence. Results of ANOVA and confidence limits of test/reference ratios of $AUC_{24th}, {\;}T_{max}, {\;}C_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\pm}20%$) except for $T_{max}$ The mean of $T_{max}$ showed only 6. 9% difference from the reference but the detection limit was 22.5% which is slightly over the 20% criteria. No pharmacokinetic parameters including Ka, Kel, Vd and Cl indicated significant difference in between the two fomulations. It was concluded that the data yielded fro the two cefriaxone formulations demonstrated that they were bioequivalent.

  • PDF