• 제목/요약/키워드: Temperature history

검색결과 677건 처리시간 0.024초

혹한온도 조건에서의 양생방법 변화에 따른 벽체 콘크리트의 온도이력 특성 (Temperature History of Wall Concrete with Heat Insulating Curing Method Subjected to Severly Cold Climate)

  • 손호정;한상윤;정상현;안상구;한천구;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.51-52
    • /
    • 2011
  • This study is to propose a curing method for a concrete wall structure under severe cold climate. The curing methods of using heated cable, heated panel and insulated form were applied. Results showed that the concrete cured by the heated cable resulted in the highest temperature history and the highest strength development at 28 days. Further, it is believed that the curing methods of the heated panel and insulated form are also recommendable for the resistance of the early frost damage on the concrete in practice.

  • PDF

광디스크 기판 성형시 발생하는 복굴절의 최소화를 위한 이론적 연구 (An Theoretical Investigation on the Minimization of Birefringence Distribution in Optical Disk Substrate)

  • 김종성;강신일
    • 소성∙가공
    • /
    • 제9권2호
    • /
    • pp.103-111
    • /
    • 2000
  • It is necessary to improve mechanical and optical properties in the optical disk substrates as the information storage density using short wavelength laser are being developed. The birefringence distribution is regarded as one of the most important optical properties for optical disk. In the present study, the birefringence distrubution is calculated using the Leonov model for viscoelastic constitutive equations and Cross/WLF model for viscosity approximation. The effects of processing conditions upon the development of birefringence discosity approximation. The effects of processing conditions upon the development of birefringence distribution in the optical disk were examined theoretically. It was found that the values of the birefringence distributions were very sensitive to the mold wall temperature history which minimizes the birefringence distribution. The analytical results showed the possibility of improving mechanical and optical properties in the optical disk substrates by active control of the mold wall temperature history.

  • PDF

유한요소해석을 이용한 핫스탬핑 공정시 발생하는 온도 이력 및 상변태 해석 (Analysis of Phase Transformation and Temperature History during Hot Stamping Using the Finite Element Method)

  • 윤승채;김도형
    • 소성∙가공
    • /
    • 제22권3호
    • /
    • pp.123-132
    • /
    • 2013
  • Hot stamping, which is the hot pressing of special steel sheet using a cold die, can combine ease of shaping with high strength mechanical properties due to the hardening effect of rapid quenching. In this paper, a thermo-mechanical analysis of hot stamping using the finite element method in conjunction with phase transformations was performed in order to investigate the plastic deformation behavior, temperature history, and mechanical properties of the stamped car part. We also conducted a fully coupled thermo-mechanical analysis during the stamping and rapid quenching process to obtain the mechanical properties with the consideration of the effects of plastic deformation and phase transformation on the temperature histories at each point in the part. The finite element analysis could provide key information concerning the temperature histories and the sheet mechanical properties when the phase transformation is properly considered. Such an analysis can also be used to determine the effect of cyclic cooling on the tooling.

매스콘크리트 구조체의 주변환경을 고려한 온도이력 해석 (Analysis of Temperature Rise History Considering Construction Environments in Mass Concrete Structural Element)

  • 이장화;변근주
    • 콘크리트학회지
    • /
    • 제8권4호
    • /
    • pp.191-199
    • /
    • 1996
  • 매스콘크리트 시공시 콘크리트의온도가 급격히 변화하면 콘크리트에는 균열이 발생하게 된다. 매스콘크리트를 타설한 후에는 구조물의 주변환경조건이 콘크리트의 온도를 변화시키게 된다. 그러나 아직도 주변환경조건을 고려하여 콘크리트의 온도이력을 엄밀하게 해석할 수 있는 해석기법이 개발되지 않은 상황이다. 본 연구에서는 대기온도, 양생온도, 거푸집재료, 거푸집의 존치 및 제거, 추가양생 등 주변환경조건이 매스콘크리트 온도이력에 미치는 영향을 정량적으로 해석하기 위하여 유한요소정식와에 열전달계수, 주변환경조건 및 거푸집조건을 도입하였고 이를 해석할 수 있는 알고리즘과 해석프로그램을 개발하였다. 본 연구의 수치모형 해석값을 모형실험값, 타연구 모형실험값 및 기존의 범용프로그램에 의한 해석값과 비교한 결과로부터 본 연구의 온도해석이론의 타당성 및 정확도를 분석하였다.

시멘트종류를 변화시킨 프리캐스트 고강도 콘크리트의 실험적 연구 - 수화열 온도특성을 중심으로 - (An Experimental Study of Precast concrete Alters Cement Types of High-Strength Concrete)

  • 박흥이;김성진;백민수;이승훈;박병근;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.119-122
    • /
    • 2009
  • As architectures have recently become high-risers and mega-structured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since not only external heating but a1so internal temperature rise caused by the accumulation of cement hydration heat in manufacturing process, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete fur precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.

  • PDF

전기발열시트에 의한 한중콘크리트의 양생 및 온도이력에 관한 실험 연구 (An Experimental Study on the Curing and Temperature History of Cold Weather Concrete by Planar Surface Heater)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.135-139
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete cured with heating sheets in the laboratory conditions. As the results, It was showed that the 130W/$m^2$-heater could raise the inner temperature more than $20^{\circ}C$ under the environmental condition of -5~$-20^{\circ}C$. And the temperature of concrete cured by the 200W/$m^2$-heater was 5~$10^{\circ}C$ higher than that of concrete cured by 130W/$m^2$-heater. Finally, through the curing by the planar surface heater during the first 1.5~2 days, it is possible to secure the sufficient maturity of concrete.

불화 유리의 냉각 속도 효과 (Cooling Speed Effects of Fluoride Glasses)

  • 류선윤
    • 한국세라믹학회지
    • /
    • 제32권2호
    • /
    • pp.183-188
    • /
    • 1995
  • The properties of the glasses are not dominantly dependent on the chemical composition, temperature, and pressure but also on the thermal history. For example, electrical, thermal, optical, and mechanical properties are all known to be strongly dependent on the thermal history. Fluoride glasses have received a great deal of attention as candidate materials for an infra-red transmitting medium. A series of fluoride glasses and fibers were prepared under a nitrogen atmosphere. Thermal history effects of the fluoride glass fibers associated with the fast cooling rate employed during the fiber drawing process were discussed in terms of the glass temperatures and the fictive temperatures on the basis of the results obtained from the Differential Scanning Calorimeter (DSC) measurements of the fiber and bulk forms of the same chemical composition.

  • PDF

적산온도방식에 의한 고유동콘크리트의 강도관리에 관한 실험적 연구 (An experimental Study on the Strength Control of High Fluidity Concrete by Maturity)

  • 김무한;남재현;김규용;길배수;한장현
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.79-87
    • /
    • 2000
  • The strength development of concrete is influenced by temperature and cement type which greatly affect hydration degree of cement. There is not pertinent concrete strength management methods for estimating the in-place strength of concrete. One such method is the maturity concept. The maturity concept is based on the fact that concrete gains strength with time as a result of the cement hydration and, thus the rate of hydration, as in any chemical reaction, depends primarily on the concrete temperature during hydration. Thus, the strength of concrete is function of its time-temperature history. This goals of the present study are to investigate a relationship between strength of high-fluidity concrete and maturity that is expressed as a function of an integral of the curing period and temperature, predict strength of concrete.

양생온도 -10℃에서 거푸집 재료 변화에 따른 콘크리트의 압축강도 특성 (Compressive Strength Properties of Concrete by the Form Material Change at 10 below Zero)

  • 최시현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2016
  • When the construction in a low temperature, the concrete performance is deteriorated by frost damage at early age. In this study, the form utilizing heating sheet and insulation is measured the performance to prevent frost damage at 10 below zero. It produced five types of the form and to measure the temperature history and compressive strength. At first, form attached heating sheet showed the highest temperature. But the form attached vacuum insulation showed the highest temperature ever since 12hours. In the case of compressive strength, the form attached heating sheet + isopink(polystyrene foam board) showed the highest compressive strength. It was followed by vacuum insulation. As a result, the form utilizing insulation and heating sheet helped to prevent frost damage.

  • PDF

양생온도 5℃에서 봉함양생방법에 따른 콘크리트의 온도 및 압축강도 특성 (Temperature and Compressive Strength Characteristics According to the Sealing Curing Method at a Curing Temperature of 5℃)

  • 배기훈;박준형;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.131-132
    • /
    • 2021
  • According to the domestic specification, the curing of the specimen for strength management used to determine the time of the mold deformity of the structure concrete in early spring and early autumn is cured in the field structure condition. However, when the seal curing is performed in the field, the temperature of the specimen is very low compared to the temperature of the actual structure, so the strength of the structure concrete predicted based on the strength of the specimen is much undervalued than the actual one, which causes the mold to be deformed. Therefore, this study analyzed the temperature history and compressive strength characteristics of the specimen for strength management through other sealing curing at 5℃ and concrete of the actual structure, and presented the most suitable curing method.

  • PDF