• Title/Summary/Keyword: Temperature Sensibility

Search Result 143, Processing Time 0.017 seconds

Passenger's Electrocardiogram Change due to Color Temperature in Case of Elevator Jam (승강기 갇힘 사고 시 색 온도에 의한 이용자의 심전도 변화)

  • Kim, Ho-Gyeom;Kim, Kyu-Beom;Jo, Hyung-Seok;Ahn, Seok-Huen;Min, Byung-Chan
    • Science of Emotion and Sensibility
    • /
    • v.23 no.3
    • /
    • pp.11-18
    • /
    • 2020
  • This study aims to suggest the most stable color temperature that can relieve the anxiety of passengers in case of an elevator trapped accident. The experiment was conducted on 10 adult men in their 20s. The color temperature of the interior lighting of the elevator was adjusted to four stages (3,000 K; 6,000 K; 9,000 K; and 12,000 K). Electrocardiogram (ECG) was measured and analyzed to observe the reaction of the user's autonomic nervous system decline in 3,000 K; 6,000 K; 9,000 K compared with 12,000 K, where a statistically significant difference was recognized (p < 0.01). Among them, the activity of the sympathetic nervous system was the lowest under the condition of 3,000 K. Through this study, it was found that the color temperature of 3,000 K induced a sense of stability among passengers in the event of an elevator jam. If the results of this study are used, it seems that the stability of passengers will be secured in the event of an elevator jam.

Emotional Evaluation about Physico-chemistry Laboratory Equipment's Exterior Design

  • Kim, Hyung-Soon;Lee, Han-Sung;Jeong, Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.269-282
    • /
    • 2012
  • Laboratory equipment will continue to be developed and created as long as experiments continue. Up until now, the designs have been focused on the functional role; successfully process the study purpose. However, nowadays, the requirements of providing emotional satisfaction of the design, has increased. Even so, the users are normally limited by specific groups and investments on these designs have been neglected due to small annual production by the small market. Through this study, we have conducted an emotional evaluation on Temperature and Humidity Chamber's (TH Chamber) exterior shape. First of all, we extracted emotional words and placed them in categories that represent these emotions and conducted an emotional evaluation on four typical TH chamber models. They were selected based on its door lock type and control box type. The result showed that the 'fixed type' of control box and the 'handle type' of door lock were most favorable by the users, satisfying the five representative emotions; 'Attractiveness', 'Classiness', 'Comfortableness', 'Pleasant' and 'Satisfaction in Usability'. Particularly, all 4 emotional words in the 'Satisfaction in Usability' category recorded over 3.65. This indicates that Satisfaction in Usability is relatively an important category when expressing laboratory equipment. The result of this research is expected to be used as a basic data to find a way of right approach in laboratory equipment design.

  • PDF

The study on the physiological response and comfort in wearing sportswear in Raniy environments (강우환경 하에서의 스포츠웨어 착용시 인체생리반응 및 쾌적감)

  • 권오경;김진아
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.194-199
    • /
    • 2001
  • 쾌적한 스포츠웨어는 기능성에 있어서 자연환경의 변화조건과 인체의 운동 및 활동에 맞추어 열절달 및 수분전달 등을 적절히 조절할 수 있어야 한다. 이에 본 연구에서는 일반환경조건 및 강우환경조건하에서의 형상기억 투습방수직물 소재의 스포츠웨어 착용에 따른 인체생리반응 및 쾌적감을 규명하기 위하여 스포츠웨어를 제작하여, 인공기후실에서 환경조건변화에 따른 온열생리학적 특성 및 주관적 감각을 측정, 그 특성을 비교, 고찰하였다. 평균피부온은 강우환경조건에서 온도가 낮게, 변동폭이 많게 나타났다. 변화경향을 운동부하를 기점으로 온도의 상승이 나타났고, 운동 2단계에 가장 높은 온도를 나타냈으며, 이후 감소하였다. 직장온은 일반환경조건에 비해 강우환경조건에서 온도의 미세한 상승을 보였다. 의복내 기후는 두 조건 모두에서 가슴부위보다 등부위의 온·습도의 변동폭이 크게 나타났고, 강우환경조건에서의 의복내 온도를 제외하고는 모두 등부위의 온·습도가 높게 나타났다. 최고 혈압은 운동의 강도에 따라 비례하여 상승하고, 최저 혈압에는 큰 영향없이 나타났으며, 변화경향은 의복내 온도의 경향과 역으로 나타났다. 평균혈압은 일반환경조건에서 6.9mmHg 높게 나타났다. 심박수는 일반환경조건에서 4.4beats/min 높게 나타났다. 강우환경조건의 주관적 감각의 평가에서, 신체에 직접 가해지는 빗물 등으로 인해 불쾌감이 증가하였고, 운동 후에는 일반환경조건과 달리 냉감이 증가하였으며, 습윤감은 최고치에 달하였다.

  • PDF

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Analysis of Optimal and Pleasant Driving Condition using Physiological Signals (생리신호 측정을 통한 심리적 적정 운전상태 분석)

  • 김정룡;황민철;박지수;윤상영
    • Science of Emotion and Sensibility
    • /
    • v.7 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • This study has investigated a psychological status of optimal and pleasant driving condition by measuring various physiological signals using SCR(skin conductance response), PPG(peripheral plethysmograph), SKT(skin temperature) and HR(heart rate). The physiological response was measured during various simulated driving conditions. We developed a hardware and algorithm to measure and analyze the physiological response. The physiological signals has reflected the level of driver's tension or relaxation as well as the heart rate. The emotional responses of drivers were also measured and analyzed in this experiment. The result of the study can be used to design a system to enhance the driver's emotional satisfaction as well as to monitor the driver's safety and health condition.

  • PDF

The Thermal Performance Comparison of BIPVT Collector Applied on Roofs and Facades (건물 적용 유형별 BIPVT 집열기 열적 실험성능 비교)

  • Gang, Jun-Gu;Kim, Jin-Hui;Kim, Jun-Tae
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.269-272
    • /
    • 2009
  • The temperature of PV modules that integrated into building facades or roof increases that could reduce the electrical efficiency of the PV system. In order to incresae PV system's efficiency it is very important to remove the heat from the PV modules. For this purpose, hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The solar collector utilizing this thermal effect is called photovoltaic-thermal(PVT) solar collector. This paper compares the experimental performance of building-integrated PVT collectors that applied on building roof and facade. There are two different case: a roof-integrated PVT type and a facade-integrated PVT type. The experimental results show that the collected thermal energy of the roof-integrated type was 24% higher, compared to that of the facade-integrated.

  • PDF

A research on attentive gaze by physiological signal (생리신호에 의한 시선 집중도 추출에 대한 연구)

  • Kim, Jong-Hwa;Hwang, Min-Cheol;Park, Gang-Ryeong;Lee, Ui-Cheol;U, Jin-Cheol;Kim, Chi-Jung;Kim, Yong-U;Kim, Ji-Hye
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.160-163
    • /
    • 2009
  • 본 연구는 생리신호에 의한 집중된 시선과 집중하지 않는 시선을 분류하고자 한다. 이를 검증하기 위해 시각적으로 높은 집중과 낮은 집중을 요구하는 두가지 과제를 피실험자에게 제시하고 PPG(Photoplethysmogram), GSR(Galvanic Skin Response) 그리고 SKT(Skin Temperature)센서를 사용한 자율신경계 반응과 시선 움직임을 측정하였다. 과제는 $3{\times}3$으로 화면 구역을 나누고 각 구역에 문자를 제시하고 역방향 문자를 찾도록 하였다. 실험에는 20 명의 대학생이 참여하였으며, 1 번의 실험에 12 종류의 다른 문자배열을 제시 받았으며 1 번의 연습을 포함하여 총 5 회 실시후 데이터를 분석하였다. 높은 집중일 경우와 낮은 집중일 경우를 T-test 분석 결과, 자율신경계에서는 높은 집중일 경우 PPG 주파수가 증가하고 GSR과 SKT는 감소한 결과를 보였다. 따라서 시선의 집중도에 따라 다른 자율신경계 반응과 시선반응을 보이는 것을 확인하였다.

  • PDF

Evaluation of Changes in Emotion Evoked by Imagination (심상 자극에 의해 유발된 감성변화의 평가)

  • 정순철;민병찬;전광진;김유나;성은정;신미경;김철중
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.182-185
    • /
    • 2001
  • 본 연구에서는 쾌, 불쾌, 긴장, 이완의 네 가지 상상을 통해 감성의 변화를 유도하였고, 생리 신호 분석을 통해 감성의 변화를 변별하고자 하였다. 20명의 피험자를 대상으로 네 가지 상상을 각각 30초씩 수행하게 하면서 EEG, ECG, GSR, PPG, RSP, Skin-Temperature를 각각 측정하였고 측정 종료 후 주관적 평가를 실시하였따. 주관적 평가 분석 결과, 피험자는 뚜렷이 구별되는 네 가지 상상을 한 것으로 나타났고, 쾌도는 “쾌 > 이완, 긴장 > 불쾌” 상상 순서의 3단계로, 긴장도는 “긴장 > 불쾌, 쾌 > 이완” 상상 순서의 3단계로 뚜렷이 구별되었다. EEG 분석 결과에서는 쾌와 불쾌, 쾌와 이완 상상 사이에서만, 자율신경계 반응 역시 약 2.5 단계의 긴장도 감성 변별이 가능하여 정확한 3단계의 감성 변별에는 어려움이 있었다. 그러나 향후 비선형 분석법을 적용하고 피험자 수를 증가시킨다면 생리 신호 분석을 통한 감성 변별 민감도를 증가시킬 수 있을 것으로 사료된다. 본 연구로부터 쾌/불쾌와 긴장/이완의 2차원의 감성 영역의 각 축을 EEG와 자율신경계의 생리 신호를 통해 변별할 수 있다는 가능성을 확인하였다.

  • PDF

Design of Multi-channel Temperature/Humidity Measurement System for Thermal Comfort Evaluatoion (온열쾌적성 평가를 위한 다채널 온습도 분포측정 시스템의 설계)

  • 한화택;김성환;김묘향;박명규;지용주
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.244-248
    • /
    • 2001
  • 본 논문에서는 온열환경 평가를 위한 다채널 온습도 분포측정 시스템을 개발하기 위하여 인체의 쾌적성에 영향을 미치는 온열환경요소를 분석, 이를 적용하기 위한 측정시스템의 설계개념과 요구사양에 고나하여 고찰하였다. 정밀도를 확보하기 위하여 센서의 응답성과 회로의 선형화에 관한 연구를 수행하고 사용자 편의를 도모하기 위한 분석 소프트웨어를 설계하였다. 소프트웨어는 의복내의 온열환경과 실내공간의 온열환경을 분석하기 위한 것으로 나누어져 있고 각각의 소프트웨어는 전처리와 후처리 프로그램 그리고 측정시스템과의 통신 인터페이스를 포함하고 있다. 이와 같은 설계 개념을 반영하여 다채널 온습도 분포측정 시스템이 개발될 경우, 각종 온열환경에 관한 연구에 널리 활용될 수 있을 것으로 기대한다.

  • PDF

Seasonal changes in clothing microclimate (의복기후의 계절적 변동)

  • 김양원
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.164-168
    • /
    • 2001
  • 의복착용시의 쾌적성은 의복의 보온력 조절에 의해 의복내 기후를 형성하여, 체온을 일정하게 유지하게 하는 역할을 하므로 건강과 직접적인 관련이 있다. 그러므로 건강이나 쾌적성 평가의 측면에서 의복내기후가 체계적으로 파악되어야 한다. 따라서 본 연구에서는 사무실 환경에서 의복착용시 착용실험을 실시하여 계절적인 의복내기후의 변동을 살펴보았다. 그 결과 겨울 31.8$^{\circ}C$, 48.6%, 봄 33.5$^{\circ}C$, 47.9%, 여름 32.7$^{\circ}C$, 64.6%, 가을 31.9$^{\circ}C$, 43.6%인 것으로 나타났다. 또한 계절간의 차이는 의복내온도에 있어서 가을과 겨울간에는 차이가 없었으며, 봄과 여름간에는 차이가 있었다. 의복내습도는 여름과 겨울간에는 차이가 없었으며, 다른 계절간에는 차이가 뚜렷하였다.

  • PDF