건물 적용 유형별 BIPVT 집열기 열적 실험성능 비교

The Thermal Performance Comparison of BIPVT Collector Applied on Roofs and Facades

  • 강준구 (공주대학교 건축공학과 대학원) ;
  • 김진희 (공주대학교 건축공학과 대학원) ;
  • 김준태 (공주대학교 건축공학과 대학원)
  • 발행 : 2009.11.20

초록

The temperature of PV modules that integrated into building facades or roof increases that could reduce the electrical efficiency of the PV system. In order to incresae PV system's efficiency it is very important to remove the heat from the PV modules. For this purpose, hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The solar collector utilizing this thermal effect is called photovoltaic-thermal(PVT) solar collector. This paper compares the experimental performance of building-integrated PVT collectors that applied on building roof and facade. There are two different case: a roof-integrated PVT type and a facade-integrated PVT type. The experimental results show that the collected thermal energy of the roof-integrated type was 24% higher, compared to that of the facade-integrated.

키워드