• Title/Summary/Keyword: Tc-99m MIBI SPECT

Search Result 90, Processing Time 0.026 seconds

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF

The Usefulness of Tc-99m MIBI SPECT in the Localization and the Assessment of Radiotherapy in Non-Small Cell Lung Cancer (비소세포 폐암의 국소화 및 방사선치료 판정에 있어 Tc-99m MIBI SPECT의 유용성)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Nam, Taek-Keum;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.186-191
    • /
    • 1994
  • Tc-99m MIBI, a lipophilic cation, was reported as a useful agent for localization of lung cancer. The effect of radiation therapy on the uptake of Tc-99m MIBI in lung cancer, however, was not well evaluated. The aim of the present study was to elucidate the usefulness of Tc-99m MIBI SPECT in the localization and the assessment of radiotherapy in non-small cell lung cancer. Twenty patients(19 males and 1 female, mean age 59, 16 squamous cell ca and 4 adenoca) were studied with Tc-99m MIBI SPECT before radiation therapy. Eleven patients(10 males and 1 female, mean age 59, 8 squamous cell ca and 3 adenoca) were repeated the study 1 month after the completion of radiation therapy(mean dose 6453cGy). All patients showed positive uptakes of Tc-99m MIBI in their tumors. One patient showed a hot uptake in atelectatic area. There was no difference of Tc-99m MIBI uptakes between squamous cell ca and adenoca either on planar or tomographic images. Tc-99m MIBI uptake ratios of squamous cell ca and adenoca were $1.50{\pm}0.16$ and $1.45{\pm}0.15$ on planar images, and $2.73{\pm}0.46$ and $2.54{\pm}0.37$ on tomographic images, respectively. The concordance between radiological change(chest x-ray and CT) and change of Tc-99m MIBI uptakes was 9/11 (81.8% ). In conclusion, Tc-99m MIBI SPECT was useful in the localization of tumor and the assessment of radiation therapy in non-small cell lung cancer.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.

Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs (폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치)

  • Kim, Seong-Suk;Kim, Ki-Beom;Cho, Young-Bok;Cho, In-Ho;Lee, Kyung-Hee;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Kim, Mi-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.54-62
    • /
    • 1996
  • Background: $^{99m}Tc$ MIBI(Methoxyisobutylisonitrile complex), a member of the isonitrile class of coordination compounds, is a lipophilic cation presently under investigation for clinical use as myocardial perfusion imaging agent and is widely used to detect myocardial infarction. Preliminary reports indicate that $T_1$-201 accumulate in human neoplasm and several authors reported $^{99m}Tc$ MIBI may also localized in primary malignant tumor and metastatic deposits from lung cancer. We evaluated the uptake of $^{99m}Tc$ MIBI in lung cancer and localization of mediastinal and other site metastasis, and compared the benign lesion of the lung. Method: Thirty four patients of lung cancer and ten patients of benign lung lesion were studied with chest CT and $^{99m}Tc$ MIBI Lung SPECT. $^{99m}Tc$ MIBI uptake ratio was assessed by TR/NL(Lung lesion/ Normal area), HT/NL (Heart/Normal area) and HT/TR(Heart/Lung lesion). Results: 1) All lung cancer patients showed increased uptakes of $^{99m}Tc$ MIBI in malignant lung lesion and Tc-99m MIBI uptake was also increased in mediastinal and lymph node metastasis except two cases. 2) There was significant different ratio of TR/NL between malignant and benign lesion, $3.79{\pm}1.82$ and $1.67{\pm}0.63$ on planar images, respectively(p<0.001). 3) There was no significant difference of $^{99m}Tc$ MIBI uptake ratio between squamous cell carcinoma, small cell carcinoma and adeno carcinoma($3.64{\pm}1.66$, $3.57{\pm}0.72$, $4.31{\pm}2.28$ respectively). Conclusion: $^{99m}Tc$ MIBI lung SPECT was useful in the localization of tumor and mediastinal or other site metastatic lesion in lung cancer and also in the differential diagnosis between benign and malignant lesion.

  • PDF

Usefulness and Comparison of $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA Single Photon Emission Computed Tomography in Distinguishing Lung Cancer from Benign Lesion (폐암과 양성질환의 감별에 $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA 단일광자전산화단층촬영술의 비교 및 가치)

  • Kim, Chang Ho;Chae, Sang Cheol;Park, Jae Yong;Jung, Tae Hoon;Ahn, Byeong Cheol;Lee, Jae Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.720-727
    • /
    • 1996
  • Objectives: $^{201}TI$ - chloride, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA SPECT has been used in distinguishing lung cancer from benign lesion. To compare the diagnostic efficacy of SPECT with these tumor - seeking agents, we perfonned three consecutive SPECT using $^{201}TI$, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA in same subjects with a solitary pulmonary lesion. Methods: SPECT was carried out at 10min and 3hr for $^{201}TI$ after injection of 20mCi, and 2hr for $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA after injection of 20mCi, respectively, in 37 patients with a solitary pulmonary lesion(27 lung cancer and 10 benign diseases). In patients showing visual uptake on lesion site, we obtained the lesion - to - background(target lesion/contralateral normal lung) uptake ratio from transverse slice for each radionuclide and also calculated the retention index for $^{201}TI$. Results: The diagnostic sensitivity of $^{201}TI$, $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA SPECT to lung cancer was 100%, 96% and 73%, and the specificity was 40%, 70% and 70%, respectively. The low specificities for these agents were mainly due to high positive uptake in patients with active pulmonary tuberculosis. There were no significant differences in uptake ratios and retention index between malignant and benign lesions, and among the histologic types of lung cancer. Conclusion : $^{201}TI$ and $^{99m}Tc$ - MIBI showed higher sensitivity than $^{99m}Tc$(V) - DMSA for detecting lung cancer, but was of limited usefulness in distinguishing lung cancer from benign lesion due to low specificity, especially in area with a high prevalence of active pulmonary tuberculosis.

  • PDF

Comparison of $^{99m}Tc$-tetrofosmin and $^{99m}Tc$-sestamibi Myocardial Perfusion SPECT in Detecting Coronary Artery Fisease (부하-휴식 1일 영상법을 이용한 심근관류 SPECT에서 $^{99m}Tc$-tetrofosmin과 $^{99m}Tc$-MIBI의 관동맥질환 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeoung, Hwan-Jeoung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.137-142
    • /
    • 1998
  • Purpose: $^{99m}Tc$-tetrofosmin(TF) is a recently proposed myocardial imaging agent which has similar biokinetic characteristics to $^{99m}Tc$-sestamibi(MIBI). The aim of this study was to compare TF and MIBI myocardial perfusion SPECTs in detecting coronary artery disease. Materials and Methods: One hundred and sixty patients(101 males, 59 females, mean age $57{\pm}9yr$) who had undergone both myocardial perfusion SPECT(M-SPECT) and coronary angiography within 1 month were studied. M-SPECT was performed using TF in 115 patients and MIBI in 45 patients. Stress-rest one day protocol was used in all patients. A coronary stenosis was considered significant when the luminal diameter ${\geq}$50% was compromised. The chi square test was used to compare differences in sensitivity and specificity between the two groups. Results: There was no difference in age and diseased coronary artery branches between the two groups. There were more male patients in TF group: Male-to-female ratios of TF and MIBI groups were 78:37 and 23:22, respectively(p<0.05). The overall sensitivity of TF study was 92% and specificity 36%. The overall sensitivity and specificity of MIBI study were 93% and 30%, respectively. There was no difference between TF and MIBI groups in identifying individual diseased coronary artery branches. Conclusion: One day stress-rest myocardial SPECT using either TF or MIBI was comparable and was a very sensitive test in detecting coronary artery disease.

  • PDF

Assessment of Regional Myocardial Wall Motion by Gated $^{99m}Tc-MIBI$ Myocardial SPECT (게이트 $^{99m}Tc-MIBI$ 심근 SPECT의 심근 분절 운동 평가능력)

  • Kim, S.W.;Lee, D.S.;Kim, S.H.;Hyun, I.Y.;Chung, J.K.;Lee, M.M.;Lee, M.C.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.473-477
    • /
    • 1995
  • Information about regional wall motion obtained with gated $^{99m}Tc-MIBI$ SPECT was compared in 23 subjects(4 normals) to echocardiography or contrast left ventriculography. Gated SPECT study using 20-30 mCi $^{99m}Tc-MIBI$ were aquired lot 8 frames/RR interval (aqusition time=40min.) and processed with Cine Mode computer protocol. Regional wall motion was assessed by visual analysis. The concordance with echocardiography was 88% and with contrast ventriculography was 78%. We conclude that gated $^{99m}Tc-MIBI$ SPECT was effective in assessing the regional wall motion with the information of regional perfusion in one study.

  • PDF

Unexpected Uptake of Tc-99m MIBI in Thymic Carcinoma: Ring-like Appearance (흉선암종에서 우연히 발견된 환 모양의 Tc-99m MIBI 섭취 증가)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae;Kim, Dong-Wook;Yim, Chang-Yeol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.255-257
    • /
    • 2007
  • A 59-year-old man with thymic carcinoma underwent Tc-99m MIBI myocardial SPECT, and Tc-99m MIBI uptake in the mass was unexpectedly found in a planar image. SPECT images of the thorax showed an increased uptake area with central photon deficiency (a ring-like appearance), which reflected central tumor irreversible ischemia or progressing necrosis with peripheral viable tumor tissue.

Recurrent Malignant Thymoma Detected by Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA Scan (Tc-99m MIBI, Tc-99m Tetrofosmin, 그리고 Tc-99m (V) DMSA 스캔에 의해 발견된 재발성 악성 흉선종)

  • Seok, Ju-Won;Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.268-273
    • /
    • 2001
  • Thymoma is the most common primary tumor of anterior mediastinum, accounting for 20% to 30% of all mediastinal tumors. The recurrence rate after total resection of the thymoma ranges 8% to 18%. We reported one patient of recurrent malignant thymoma imaged with Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA. Early and delayed Tc-99m MIBI and Tc-99m Tetrofosmin scintigraphies showed an increased uptake in the mediastinal area. Also, Tc-99m (V) DMSA scintigraphy revealed an increased uptake tn the corresponding area. Coronal SPECT images of Tc-99m MIBI, Tc-99m Tetrofosmin and Tc-99m (V) DMSA revealed increased uptake of each radiopharmaceutical in the tumor lesion corresponding to the mediastinal lesion on the chest CT. However, the normal blood pool activities of the heart and great vessels of Tc-99m (V) DMSA obscured the recurrent malignant thymoma. Although Tc-99m (V) DMSA is a useful tumor seeking agent, we recommend Tc-99m MIBI and Tc-99m Tetrofosmin SPECT rather than Tc-99m (V) DMSA to detect primary and recurrent malignant thymoma.

  • PDF