• Title/Summary/Keyword: Tc-99m

Search Result 1,347, Processing Time 0.028 seconds

Renal Anomalies in Children with Turner Syndrome (Turner 증후군 환자에서 신기형에 관한 연구)

  • Kim, Ji Young;Hong, Sun Young;Park, Young Mi;Park, Yong Hoon;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.891-895
    • /
    • 2002
  • Purpose : The prevalence of renal anomalies in Turner syndrome(TS) has been reported to vary from 33% to 60%. The purpose of this study was to clarify the true incidence of renal malformations in Korean TS. Methods : We evaluated 33 patients with Turner syndrome diagnosed by karyotype in Inje University Busan Paik hospital and Youngnam University from January 1995. Intravenous pyelography(IVP) was performed on all patients; abdominal ultrasonography and 99mTc-DMSA renal scan were performed on some. Cytogenetic analysis was performed on all patients with peripheral blood lymphocytes. Results : Of the total 33 patients, the karyotype showed 45, X in 18(54.5%) patients, mosaicism in 11(33.3%) patients and structural aberration in 4(12.2%) patients. The overall incidence of renal anomalies was 36.4%. The renal anomalies included four cases of horeshoe kidney, six cases of abnormal renal collecting system one case of single kidney and one case of malrotation. The incidence of renal anomalies in 45, X karotype(44.4%) showed a higher rate than that of mosaicism and structural aberration(26.7%), but there is no statistical significance. Conclusion : The incidence of renal anomalies in Korean TS reveals 36.4%. This rate is similar to other foreign TS studies. We recommend that renal ultrasonography or IVP for investigation of renal anomalies should be done as a screening procedure for the better quality of life in patients with TS.

An Improved Online Algorithm to Minimize Total Error of the Imprecise Tasks with 0/1 Constraint (0/1 제약조건을 갖는 부정확한 태스크들의 총오류를 최소화시키기 위한 개선된 온라인 알고리즘)

  • Song, Gi-Hyeon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.10
    • /
    • pp.493-501
    • /
    • 2007
  • The imprecise real-time system provides flexibility in scheduling time-critical tasks. Most scheduling problems of satisfying both 0/1 constraint and timing constraints, while the total error is minimized, are NP-complete when the optional tasks have arbitrary processing times. Liu suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on uniprocessors for minimizing the total error. Song et at suggested a reasonable strategy of scheduling tasks with the 0/1 constraint on multiprocessors for minimizing the total error. But, these algorithms are all off-line algorithms. In the online scheduling, the NORA algorithm can find a schedule with the minimum total error for the imprecise online task system. In NORA algorithm, EDF strategy is adopted in the optional scheduling. On the other hand, for the task system with 0/1 constraint, EDF_Scheduling may not be optimal in the sense that the total error is minimized. Furthermore, when the optional tasks are scheduled in the ascending order of their required processing times, NORA algorithm which EDF strategy is adopted may not produce minimum total error. Therefore, in this paper, an online algorithm is proposed to minimize total error for the imprecise task system with 0/1 constraint. Then, to compare the performance between the proposed algorithm and NORA algorithm, a series of experiments are performed. As a conseqence of the performance comparison between two algorithms, it has been concluded that the proposed algorithm can produce similar total error to NORA algorithm when the optional tasks are scheduled in the random order of their required processing times but, the proposed algorithm can produce less total error than NORA algorithm especially when the optional tasks are scheduled in the ascending order of their required processing times.

Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis (척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구)

  • Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju;Kim, Yong-Ki;Kim, Ju-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.218-228
    • /
    • 2008
  • Purpose: Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. Material and Methods: FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). Results: A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p < 0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p = 0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. Conclusion: A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

The Gastric-Bile Juice Reflux in Patients from Hepatobiliary Scan with Subtotal Gastrectomy (위 부분절제술 환자의 간담도 스캔에서 위-담즙역류)

  • Kwak, Dong-Woo;Kim, Ji-Hyeon;Kim, Kyung-Hun;Lee, Kyung-Jae;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.17-20
    • /
    • 2010
  • Purpose: The hepatobiliary scan is the examination which is the possibility of knowing the function of liver, gall bladder and closing of the biliary tract. Also, after subtotal gastrectomy, the increased gastric-bile reflux is known as the primary reason of reflux gastritis. In this study, according to changing the acquisition method, we tried to prove the reflux time and reflux index in patients who underwent subtotal gastrectomy. Materials and Methods: From Oct 2008 to Jan 2009, 72 patients with subtotal gastrectomy who took the hepatobiliary scan (man: 52, woman: 20, age range: 31-77, mean age: $60.5{\pm}7$) in our department. We used the radiopharmaceutical $^{99m}Tc$-mebrofenin 185 MBq/0.5 cc. After 5 minutes, we acquired 300,000 counts anterior image on supine, and then we acquired right lateral and $45^{\circ}$ LAO position by using the time setting method. We acquired 30 min, 60 min, 90 min, 120 min and fatty meal by the same method. We painted the ROI of liver, GB and CBD on 30 min anterior image and LAO image in patients had occurred the bile juice reflux. And then we painted the ROI of stomach on others image. We calculated the reflux index from those values. Results: According to this study, we found out 40 patients (55.6%) who had occurred the gastric-bile juice reflux (1 person from 30 min, 7 persons from 60 min, 4 persons from 90 min, 28 persons from after fatty meal). Hourly, the bile reflux highest level is 6 persons from 60 min, 2 persons from 90 min, 32 persons from fatty meal among those people. The reflux index of anterior is 0.85-23.36% (mean 6.53%). The reflux index of LAO is 1-29.13% (mean 8.89%). By visual assessment, we can distinguish that there were 26 of the 40 patients (65%) had occurred the reflux on LAO image more than anterior image. Conclusion: We find out that the patients with subtotal gastrectomy had occurred gastric-bile juice reflux more than 50% from hepatobiliary scan. And after eating fatty meal, we can know that it's the most possible to occur the gastric-bile juice reflux. When it happened, we have to change the acquisition method to reduce the overlap between colon and stomach. This study will be more valuable in diagnosis.

  • PDF

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

Factors Associated with Renal Scar in Children with Vesicoureteral Reflux (방광 요관 역류가 있는 소아에서 신반흔 형성과 관련된 인자들)

  • Kim Kyoung Hee;Jang Sung Hee;Lee Dae-Yeol
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • Purpose : The urinary tract infection associated with vesicoureteral reflux(VUR) in children may result in serious complications such as renal scarring, hypertension, proteinuria and end stage renal disease. The purpose of this study was to evaluate the factors affecting renal scar such as age, gender, grade of VUR, and ACE gene polymorphism, and body growth in the patients with and those without renal scar associated with VUR Methods : During the period from January 1994 to July 2000, We had 93 children with urinary tract infection associated with VUR who were admitted to the Department of pediatrics of Chonbuk National University Hospital. The patients were divided into two groups according to follow up 99mTc-DMSA renal scan; patients with renal scar group and those with non-scar group. We analyzed and compared the factors associated with renal scarring between the two groups. Results : There were no significant difference in gender, causative organism, ACE gene polymorphism, height and weight at diagnosis between renal scar group and non-scar group. Fifty four patients were in renal scar group and forty seven of them had VUR. The age at diagnosis was significantly higher in renal scar group (2.48${\pm}$2.64yr) than in non renal scar group (1.26${\pm}$1.83yr). Especially, the infants who were less than 1 year of age with VUR developed relatively more renal scar compared with infants older than 1 tear of age. The incidence of renal scarring showed a direct correlation with the severity of VUR. Conclusion : The factors affecting renal scar formation were age at diagnosis, presence and grade of VUR, but the other factors such as gender, causative organism, ACE gene polymorphism were not associated with renal scarring. Therefore, further evaluation about uropathogenic E coli and foflow up study about body growth associated with severity of renal scar would be necessary. (J. Korean Soc Pediatr Nephrol 5 : 43- 50, 2001)

  • PDF

Clinical Characteristics and Renal Outcomes of Acute Focal Bacterial Nephritis in Children (소아 급성 세균성 신엽염의 임상상 및 신장 예후)

  • Lee Dong-Ki;Kwon Duck-Geun;Lim Yun-Ju;Shin Yun-Hye;Yun Suk-Nam;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.229-238
    • /
    • 2004
  • Purpose: This study was perfonned to elucidate the clinical pictures of acute focal bacterial nephritis(nephronia) in children. Methods: We reviewed 9 children with nephronia diagnosed by ultrasonography or computed tomography of kidneys from September 1994 to August 2004. Results: The overall male to female ratio was 2:1, and the age distribution ranged from 0.1 to 6 years(mean $2.8{\pm}2.2$). The cardinal symptoms were fever, chills, abdominal pain and dysuria/frequency. The initial leukocyte count was $21,000{\pm}5,600/uL$, ESR $60{\pm}23mm/hr$, CRP $17{\pm}10\;mg/dl$. Pyuria was noted in every patient and persisted for $10.5{\pm}7.8$ days after antimicrobial treatment. Abdominal sonography demonstrated focal lesion of ill-defined margin and low echogenicity in 5 of 9 patients(55.6%), while computed tomography revealed nonenhancing low density area in all patients(100%). Three of 9 patients(33.3%) had vesicoureteral reflux, greater than grade III. The initial $^{99m}Tc-DMSA$ scan showed one or multiple cortical defects in every patient, and improvements were noted in 2(33.3%) of 6 patients who received follow up scan after 4 months. Intravenous antibiotics was given in every patient under admission. Total febrile period was $11.8{\pm}6.3$ days(pre-admission, $4.0{\pm}3.0;$ post-admission, $7.8{\pm}5.5$ days) and the patients needed hospitalization for $17.2{\pm}8.1$ days. Conclusion: For the early diagnosis of 'acute focal bacterial nephritis' we should perform renal computed tomography first rather than ultrasonography, when the child has toxic symptoms and severe inflammatory responses in blood and urine.

  • PDF