• Title/Summary/Keyword: Target System Test

Search Result 831, Processing Time 0.024 seconds

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

A simulation code generator for AGVS design (무인운반차시스템의 설계를 위한 시뮬레이션 코-드 작성시스템)

  • 김갑환;김판수;배종욱
    • Korean Management Science Review
    • /
    • v.11 no.1
    • /
    • pp.1-21
    • /
    • 1994
  • We usually use the simulation technique in the evaluation and the test of a design alternative of Automated Guided Vehicle System. In this paper, we introduce a simulation code generator which can assist simulation programmer in model development and programming. It consists of user interface, program editor, and program sorter. SIMAN is used as the target language.

  • PDF

Design and Verification of PCI 2.2 Target Controller to support Prefetch Request (프리페치 요구를 지원하는 PCI 2.2 타겟 컨트롤러 설계 및 검증)

  • Hyun Eugin;Seong Kwang-Su
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.523-530
    • /
    • 2005
  • When a PCI 2.2 bus master requests data using Memory Read command, a target device may hold PCI bus without data to be transferred for long time because a target device needs time to prepare data infernally. Because the usage efficiency of the PCI bus and the data transfer efficiency are decreased due to this situation, the PCI specification recommends to use the Delayed Transaction mechanism to improve the system performance. But the mechanism cann't fully improve performance because a target device doesn't know the exact size of prefetched data. In the previous work, we propose a new method called Prefetch Request when a bus master intends to read data from the target device. In this paper, we design PCI 2.2 controller and local device that support the proposed method. The designed PCI 2.2 controller has simple local interface and it is used to convert the PCI protocol into the local protocol. So the typical users, who don't know the PCI protocol, can easily design the PCI target device using the proposed PCI controller. We propose the basic behavioral verification, hardware design verification, and random test verification to verify the designed hardware. We also build the test bench and define assembler instructions. And we propose random testing environment, which consist of reference model, random generator ,and compare engine, to efficiently verify corner case. This verification environment is excellent to find error which is not detected by general test vector. Also, the simulation under the proposed test environment shows that the proposed method has the higher data transfer efficiency than the Delayed Transaction about $9\%$.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

The Study on the Development of the Car Driver's Front Attention Enhancement System using the Car Camera (차량카메라 영상을 이용한 운전자 전방 주의력향상 시스템 개발에 관한 연구)

  • Lee, Sang-Ha;Shim, Min Kyung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.75-81
    • /
    • 2018
  • In this paper for developing and implementing the car driver's front lane attention enhancement developed system using the car camera. The developed system automatically alarm the car driver when front cars make the dangerous situation. We use Raspberry Pi camera module V2 as car camera module, Raspberry Pi 3 board as hardware main board of implementing embedded system and develop the application library module which can be operated on the Raspberry situation. The application library module widely consist of two part, front car recognition part and dangerous situation distinguish part. Our developed system satisfy the performance test of the target system at the software test certification laboratory of TTA(Telecommunication Technology Association). We test four items as attentive car recognition ability at day and night, system performance, response time. We get the performance of developed system based on the four goal. The car driver's front lane attention enhancement system in this paper will be widely used at the ADAS(Advanced Driving Assistance System) because of the better performance and function.

Test bed for autonomous controlled space robot (우주로봇 자율제어 테스트 베드)

  • 최종현;백윤수;박종오
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1828-1831
    • /
    • 1997
  • this paper, to represent the robot motion approximately in space, delas with algorithm for position recognition of space robot, target and obstacle with vision system in 2-D. And also there are algorithms for precise distance-measuring and calibration usign laser displacement system, and for trajectory selection for optimizing moving to object, and for robot locomtion with air-thrust valve. And the software synthesizing of these algorithms hleps operator to realize the situation certainly and perform the job without any difficulty.

  • PDF

Effect of System Parameters on Target Parameters in Extrusion Cooking of Corn Grit by Twin-Screw Extruder (옥분 압출가공시 이축압출성형기의 System Parameters에 따른 압출물의 특성변화)

  • Kim, Ji-Yong;Kim, Chong-Tai;Kim, Chul-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.88-92
    • /
    • 1991
  • To analyze the effects of the system parameters on the target parameters, which include the amount of water evaporation, water solubility index(WSI) and water absorption index(WAI), test trials of fractional factorial design of the three process variables at three levels were carried out for corn grit with a laboratory twin-screw extruder with three different screw configurations. The system parameters collected from the trials, such as extrusion temperature, specific mechanical energy input(SME) and mean residence time(RT), were showed the ranges of $129{\sim}182^{\circ}C$, $67{\sim}163\;kwh/ton$ and $12{\sim}34\;sec$, respectively. Within these ranges of the system parameters, the target parameters were able to be quantified by using multiple regression equations. The correlation of results with the system parameters blocked by the screw configuration as dependent variables, yield correlation coefficients above 0.90, and the correlation using the system parameters obtained from whole experiment system as the dependent variables yield correlation coefficients around 0.80. The functional relationship, which can be quantified by second order polynomial regression equation with only two system parameters within necessary degree of accuracy, can he graped in three dimensional surface response and contour diagrams.

  • PDF

Recipe Prediction of Colorant Proportion for Target Color Reproduction (목표색상 재현을 위한 페인트 안료 배합비율의 예측)

  • Hwang, Kyu-Suk;Park, Chang-Won
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.438-445
    • /
    • 2008
  • For recipe prediction of colorant proportion showing nonlinear behavior, we modeled the effects of colorant proportion of basic colors on the target colors and predicted colorant proportion necessary for making target colors. First, colorant proportion of basic colors and color information indicated by the instrument was applied by a linear model and a multi-layer perceptrons model with back-propagation learning method. However, satisfactory results were not obtained because of nonlinear property of colors. Thus, in this study the neuro-fuzzy model with merit of artificial neural networks and fuzzy systems was presented. The proposed model was trained with test data and colorant proportion was predicted. The effectiveness of the proposed model was verified by evaluation of color difference(${\Delta}E$).

A Study on the Design Process of Steering System considering Frequency and Sensitivity (주파수와 감도를 고려한 스티어링 시스템 설계 프로세스 연구)

  • Kim, Ki-Chang;Kim, Chan-Mook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.208-211
    • /
    • 2005
  • This paper describes the development process of steering system for reduce idle vibration through the data level of frequency and sensitivity. High stiffness and light weight vehicle is a major target in the refinement of passenger cars to meet customers' contradictable requirements between NVH performance and fuel economy. The target frequency of the steering system is set by benchmarking of a competitive vehicle and the vibration mode map is used to separate steering column modes from resonance of body structure and engine idle rpm. This paper descirbes the analysis approach process for high stiffness of steering system and the design guideline is suggested about steering column and support system by using mother car at initial design stage. We used a patent map in order to analyze accurately a technical trend and suggested the design process using dynamic damper of steering system considering sensitivity. And we established techniques of analysis on steering system and evaluated the level of accuracy of analysis through correlating the test and analysis results. It makes possible to design the good NVH performance vehicle at initial design stage and save vehicles to be used in tests. These improvements can lead to shortening the time needed to develop better vehicles.

  • PDF

Automatic identification of ARPA radar tracking vessels by CCTV camera system (CCTV 카메라 시스템에 의한 ARPA 레이더 추적선박의 자동식별)

  • Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.3
    • /
    • pp.177-187
    • /
    • 2009
  • This paper describes a automatic video surveillance system(AVSS) with long range and 360$^{\circ}$ coverage that is automatically rotated in an elevation over azimuth mode in response to the TTM(tracked target message) signal of vessels tracked by ARPA(automatic radar plotting aids) radar. This AVSS that is a video security and tracking system supported by ARPA radar, CCTV(closed-circuit television) camera system and other sensors to automatically identify and track, detect the potential dangerous situations such as collision accidents at sea and berthing/deberthing accidents in harbor, can be used in monitoring the illegal fishing vessels in inshore and offshore fishing ground, and in more improving the security and safety of domestic fishing vessels in EEZ(exclusive economic zone) area. The movement of the target vessel chosen by the ARPA radar operator in the AVSS can be automatically tracked by a CCTV camera system interfaced to the ECDIS(electronic chart display and information system) with the special functions such as graphic presentation of CCTV image, camera position, camera azimuth and angle of view on the ENC, automatic and manual controls of pan and tilt angles for CCTV system, and the capability that can replay and record continuously all information of a selected target. The test results showed that the AVSS developed experimentally in this study can be used as an extra navigation aid for the operator on the bridge under the confusing traffic situations, to improve the detection efficiency of small targets in sea clutter, to enhance greatly an operator s ability to identify visually vessels tracked by ARPA radar and to provide a recorded history for reference or evidentiary purposes in EEZ area.