Process Simulation of LH2 Receiving Terminal with Membrane Storage Tank and Prediction of BOG Generation According to Change of Design Conditions (LH2 멤브레인 저장탱크 인수기지 공정모사 및 설계조건 변화에 따른 BOG 발생량 예측)

  • Kim, Donghyuk;Lee, Yeongbeom;Seo, Heungseok;Kwon, Yongsoo;Park, Changwon;Kwon, Hweeung
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.49-57
    • /
    • 2022
  • If the hydrogen industry is activated in the future, the LH2 receiving terminal with membrane storage tank is a major way to store and send large capacity hydrogen. Since such a LH2 receiving terminal does not currently exist, the process simulation model of it was completed by referring to the design data on existing LNG receiving terminal with same typed storage tank. Based on this model, the amount of BOG generation according to change of design conditions, which is a very important factor in the operation of LH2 receiving terminal, was predicted. Through this, it was attempted to review the appropriate operating conditions to minimize the amount of BOG generated during unloading in LH2 receiving terminal with membrane storage tank.

Case Study on Seepage Analysis and Countermeasure Against the Seepage Flow of In-ground LNG Storage Tank (LNG 지하저장탱크의 침투해석 및 용수 대책공법에 대한 사례분석)

  • 신은철;오영인;이상혁
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.65-72
    • /
    • 2001
  • Since Pyoungtaek thermal power plant began using natural gas in 1986, the annual using volume has rapidly increased and reached 12.7 million tons in 1999. When the natural gas is cooled to a temperature of approximately -162$^{\circ}$C at atmospheric pressure, it condenses to a liquid called liquefied natural gas(LNG). LNG has a special characters such as odorless, colorless, non-corrosive, and non-toxic. So, LNG storage tank, tanker ship, transfer pipelines are required the special storage and transportation systems and technology. The presently operating LNG terminals are Pyongtaek and Inchon terminals. A total of 19 above-ground LNG storage tanks(100 thousand ㎘ grade) are currently in operation with a sendout capacity of 4,360tons/hour. To meet the growing domestic demand of LNG supply, the Inchon receiving terminal is expanding(six in-ground tank) and constructing a third LNG terminal at Tongyong. In this paper, case study on seepage analysis and countermeasure against increasing the seepage volume of in-ground LNG storage tank excavation work is reported. The results of an additional seepage analysis are presented to verify the design seepage volume of assumption section and seepage volume after curtain-grouting in the slurry wall.

  • PDF

A Study on Global Strategies of Tank Terminal Operators and Implications for Korea's Oil Hub Policy in Northeast Asia (탱크터미널 운영기업의 글로벌 전략과 우리나라의 동북아 석유물류허브 정책에 대한 시사점)

  • Lee, Choong-Bae;Park, Sun-Young
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.1
    • /
    • pp.63-86
    • /
    • 2009
  • With increasing uncertainty of energy market in the world, the policies for the energy resource security have become crucial Several countries with poor energy resource like Netherlands and Singapore have pursued the policy for becoming an oil hub in the region. Singapore has been an oil hub in East Asia for a long time not only because it is well located with a large number of countries exporting and importing oil but it has also pursued strong policies to become an oil hub while establishing favourable institutional, regulatory and business environment for accommodating major refineries and petro-chemical companies. However with growing trading volume of petroleum products in Northeast Asia and a record high price of oil in these days, the necessities of another oil hub in the region are considered in order to reap benefits of the security of economical and stable oil. South Korea is situated astride the main North Pacific shipping route, with deep water ports and proximity to Chinese and Japanese industrial centres that make tank terminal operators Ideal choices for the oil hub in Northeast Asia although it has several disadvantages such as lack of independent storage facilities, underdeveloped oil trading market and unfavourable business friendly climates etc. This study is focused on examining the globalization strategies of tank terminal operators such as Vopak, Oiltanking and Odfjell in order to suggest the policy implications for becoming an oil tub in Northeast Asia.

  • PDF

A Safety Assessment for 140,000kl $9\%$ Ni Steel Type LNG Storage Tank (140,000kl $9\%$니켈강식 액화천연가스 저장탱크의 안전성 평가)

  • Lee Su Kyung,;Yang Byung Dong,
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.57-62
    • /
    • 2004
  • This study is to assess the safety of the process facilities and fire fighting facilities for LNG storage tank which is the main facility in the LNG receiving terminal. The LNG storage tank(capacity : 140,000kl, type : aboveground, inner tank $9\%$ Ni steel plate, outer tank : prestressed concrete) was designed by foreign country up to now, but it has designed by domestic technology as the fifth in the world is under construction now.

  • PDF

Study on Cool-down Analysis Technology for Large Scale Liquid Hydrogen Receiving Terminal (대용량 액체수소 인수기지 쿨다운 해석 기술 연구)

  • CHANG-WON PARK;DONG-HYUK KIM;YEONG-BEOM LEE;HEUNG-SEOK SEO;YOUNG-SOO KWON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.34-39
    • /
    • 2024
  • Korea government is trying to supply liquid hydrogen from another country to domestic The research for liquid hydrogen transportation and liquefaction plant of hydrogen underway for several years, and empirical research is also planned in the future. Along with the development of liquid hydrogen transport ship/liquefaction plant technology, the development of liquid hydrogen reception base technology must be carried out. In this study, a concept level liquid hydrogen receiving terminal is constructed based on the process of the LNG receiving terminal. Based on this, a study is conducted on the development of analysis technology for the amount of BOG (pipe, tank) generated during cooldown and unloading in the liquid hydrogen unloading line (loading arm to storage tank). The research results are intended to be used as basic data for the design and liquid hydrogen receiving terminal in the future.

Analysis of LH2 Tank Behavior through Computational Simulation of C-Type LH2 Carrier on Voyage and Unloading Process (C-Type LH2 운송선박 운항 및 하역공정 전산모사를 통한 LH2 탱크 거동 분석)

  • DONGHYUK KIM;YEONGBEOM LEE;HEUNGSEOK SEO;YONGGI MO;CHIHUN LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.827-837
    • /
    • 2022
  • If the hydrogen industry is activated, the introduction of C-type and pressurized liquefied hydrogen (LH2) tank suitable for small and medium-sized transp- ortation and storage will be given priority in the future. Therefore in this paper, the behavior for the LH2 property changes and boil-off gas (BOG) treatment of the C-type cargo tank through voyage of the LH2 carrier and pressurized tank of the LH2 receiving terminal were analyzed through computational simulations by making assumptions about the carrier operation and unloading conditions.

The Investigation of Accidental Case for LNG Terminal (LNG 생산기지의 사고사례 조사)

  • Ma, Y.W.;Lee, S.R.;Yoon, K.B.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.47-51
    • /
    • 2006
  • Safety issues for LNG(Liquified Natural Gas) terminal or LNG tank involve various concerns such as production/transportation at cryogenic temperature of $-160^{\circ}C$, large volume of handling, flammability and explosion risk. Hence, in designing an LNG terminal rigid safety criteria and mandatory requirements are unavoidable. Since known cases of LNG related accident are very few, careful study and root cause analysis of them are very important and provide precious information to increase safety level of the LNG terminal. In this paper most key accident cases were gathered and analysed to understand fundamental safety issues of LNG terminal to prevent further accident.

  • PDF

Fuzzy Rule-Based Adaptive Kalman Filter for State Estimation of Anti-Tank Threats (대전차 위협체 상태추정을 위한 퍼지 규칙기반 적응적 칼만필터)

  • Lee, Eui-Hyuk;Cho, Kyu-Gong;Park, Sang-Soon;Kang, Youn-Sik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.57-65
    • /
    • 2012
  • To neutralize fast Anti-Tank Guided Missiles(ATGMs) or Anti-Tank Rockets(ATRs) projected at short ranges, the trajectories and times that the threats arrive at hard-kill systems should be predicted precisely. The trajectories of ATGMs or ATRs are almost stationary but the velocity and acceleration are very changeable in the terminal stage, so that it is needed to predict the characteristics of ATGMs and ATRs for filtering. In this paper the Fuzzy Rule based Adaptive Kalman Filter(FRAKF) is proposed to estimate the position, velocity and acceleration of the threats with accuracy and the performance of it is compared with the existing tracking filter considering the maneuvering characteristics of threats.

Case Study on Optimization of Send-out Operation in Liquefied Natural Gas Receiving Terminal (LNG 터미널 송출 운전 최적화 사례 연구)

  • Park, Chansaem;Han, Chonghun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.150-155
    • /
    • 2015
  • Recently, LNG receiving terminals have been widely constructed and expanded for an increase in LNG demand. Selection of the storage tank for send-out and estimation of send-out flow rate have significant influence to process operation and economics. In this study, a send-out flow rate of each storage tank is optimized in order to minimize the total BOG generation rate. Considering a size and characteristic of each storage tanks, BOG flow rates are estimated using a dynamic simulation with varying liquid levels in the tanks. The regression model is developed fitting BOG flow rates and tank liquid levels, which are boil off rate model to predict BOG flow rates with particular level data. The objective function and constraints including required total send-out flow rate and level limit in the tanks are formulated to optimize a send-out flow rate of each tank. This method for optimization of send-out operation is applied to the Incheon LNG receiving terminal considering two scenarios for various liquid levels and maximum and minimum required send-out flow rates. For maximum required send-out flow rate, this method achieves BOG reduction of 9% comparing with assumed conventional operation.