• 제목/요약/키워드: TVOCs s

검색결과 14건 처리시간 0.023초

화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구 (Characteristics of TVOCs Emission Factors from Chemical and Natural Coating Materials)

  • 김신도;김정호;박진수;이정주
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.487-492
    • /
    • 2004
  • Building materials are composed of very complex chemical compounds, and these indoor building materials discharge very much Volatile Organic Compounds(VOCs). We performed the environmental chamber test to investigate the Total VOCs(TVOCs) emission characteristics and emission factors about chemical and natural coating materials. As the result, we concluded that TVOCs emission are high at initial time and decreased in course of time. Natural paint was low emission level for TVOCs than chemical paint by small chamber test. The TVOCs emission factor-time profile showed a good fit with the results from the measured and predicted value.

Sliding Arc Plasma를 이용한 석유공장에서의 BTX 처리효율에 관한 연구 (BTX Treatment of a Petrochemical Plant by Sliding Arc Plasma)

  • 권우택;권이승;이우식
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.65-70
    • /
    • 2015
  • 본 연구는 울산소재 석유공장의 건조시설에서 발생하는 가스를 스크러버(Scrubber)로 최종 처리하여 배출되는 저 농도의 유해가스와 산 처리 시설에서 발생되는 고 농도로 발생하는 유해가스를 대상으로 연구하였다. 공정별로 벤젠(Benzene), 톨루엔(Toluene), 자일렌(Xylene) 및 총휘발성유기화합물(TVOCs)을 대상으로 측정하였으며 농도 측정은 TVOCs 측정기와 GC-MSD를 이용하여 SAP 전 후단의 TVOCs와 BTX의 농도를 측정, 분석하여 제거효율을 평가하였고, SAP 반응기는 5 단계로 구성하여 실험을 수행하였다. 슬라이딩 아크 프라즈마(slidind arc plasma) 반응기의 단수별에 따른 TVOCs 농도 변화는 유입 TVOCs 농도의 변화에 따른 처리효율 결과 481 ppm 미만에서 94.83%, 481 ppm 이상일 경우에는 1단에서는 89.07% 2단에서는 약 91% 이상으로 처리되는 것을 확인할 수 있었다. 본 연구의 결과는 석유화학공정 및 제조시설에서 SAP 공정을 통한 VOCs 제거에 대한 연구 및 기술개발의 기초가 되어 VOCs의 보다 안정적인 처리와 다양한 기술개발에 효과가 있을 것으로 기대해 본다.

조선소 용접작업 중 오존 및 TVOCs의 노출평가와 사용 호흡보호구의 적합성 (Exposure to Ozone and TVOCs during Shipyard Welding and the Adequacy of RPE)

  • 한돈희;김동환
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.200-210
    • /
    • 2018
  • Objectives: The purpose of this study is to assess the exposure to ozone and total volatile organic compounds(TVOCs) generated during welding work at a shipyard and recommend respiratory protective equipment(RPE) adequate against these hazards. Method: Ozone was collected for about 30 minutes at two-minutes intervals using a direct reading instrument, specifically an ozone analyzer(Serinus 10, Ecotech, Australia). TVOCs were collected for about 30 minutes at three-minute intervals using a portable GC (Alpha 115, Synspec BV, the Netherlands), and were determined simultaneously by area sampling at the welding plume closest to the welder's breathing zone. The total measurements were 162 for ozone($CO_2$ welding 47, TIG 60, stick 55), and 136 for TVOCs($CO_2$ 65, TIG 50, stick 21). Based on these measurements, a literature survey was conducted to assess the adequacy of RPE. Results: Relative to Korean OEL, measurements above STEL 0.2 ppm were 23.4% for $CO_2$, 63.3% for TIG and 14.5% for stick welding. There were significant differences(p=<0.0001) among welding types. Compared with ACGIH peak exposure of 0.4 ppm for ozone, which is not applied in Korea, $CO_2$ welding exceeded it by 10.6%, TIG by 40.0% and stick by 7.3%. Although it was not feasible to compare them directly since there are no Korean OEL, TVOCs had very high levels similar to the concentrations before moving into a new apartment and about 10-20 times the indoor air quality recommendations for some individual measurements. Conclusions: As ozone removal RPE has been recommended in welding environments for a long time(Lunau, 1967), this fact was demonstrated based on the results of the on-site work environment measurements(ozone and TVOCs). In conclusion, for all welding at a shipyard, gas/vapor and particulate combination RPE are recommended. If this is not possible, it should at least be present for TIG welding.

거주자 안전을 고려한 친환경건축자재의 HCHO 듬급에 관한 고찰 (A Study on the HCHO Grade of Architectural Material's Standard for Greenness with Consideration for Residents' Safety)

  • 송혁;고성석;정우양
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.133-140
    • /
    • 2006
  • 1997년 도쿄의정서(protocol)에서는 지구환경오염에 대한 오염원방지를 제안하는 협정으로 우리나라에서도 배출기준에 감소하기 위한 노력의 일환으로 건축자재에 대한 방출농도 기준을 마련하고 있는 실정이다. 그러나, 최근 건축공사에는 많은 종류의 건축자재와 내장재료가 사용되고 있으며, 특히 화학기술의 발달로 복합재료로 구성된 건축재료들에 대한사용이 증가하고 있다. 실내건축자재에서 방출되는 물질로 인하여 재실자들에게 두통, 현기증, 메스꺼움, 졸음, 집중력 감퇴 등의 각종 질병을 불러일으키는 '새집 증후군'과 같은 현상을 야기 시켜 건강 상 많은 영향을 주고 있는 것으로 조사되고 있으며, 이러한 문제 해결을 위해서는 각 나라마다 건축물에 사용되어 지는 건축자재에 대한 유기 화합물의 방출농도를 최소화하는 친환경 건축자재의 선정을 권고하는 실정이다. 이에 본 연구에서는 건축자재의 TVOCs 에 대한 HCHO의 등급기준을 제안하고자 한다.

발생원에 따른 일부 학교 교실의 실내공기질 평가 사례연구 (Assessment of Indoor Air Quality of Classroom in School by Means of Source Generation - Case Study)

  • 양원호;변재철;김영희;김대원;손부순;이정은
    • 한국환경과학회지
    • /
    • 제14권10호
    • /
    • pp.979-983
    • /
    • 2005
  • Indoor air quality has been addressed as an important atmospheric environmental issue and has caught attention of the public in recent years in Korea. Good indoor air quality in classrooms favour student's learning ability, teacher and staff's productivity according to other studies. In this study, each classroom at four different schools was chosen for comparison of indoor and outdoor air quality by means of source generation types such as new constructed classroom, using of cleaning agents and purchased furniture. Temperature, relative humidity (RH), carbon dioxide $(CO_2)$, formaldehyde (HCHO), total volatile organic compounds (TVOCs) and particulate matter with diameter less than $10{\mu}m\;(PM_{10})$ were monitored at indoor and outdoor locations during lesson. HCHO was found to be the worst among parameters measured in new constructed classroom, HCHO and TVOCs was worst in classroom with new purchased furniture, and TVOCs was worst in classroom cleaned by cleaning agents, Indoor $(CO_2)$ concentrations often exceeded 1500 ppm indicating importance of ventilation. Active activity of students during break time made the $PM_{10}$ concentration higher than a lesson, Improvements and further researches should be carried out considering indoor air quality at schools is of special concern since children and students are susceptible to poor air quality.

유해오염물질 처리를 위한 흡연부스의 설계 (Study of Smoking Booth Design for the Treatment of Hazardous Pollutants)

  • 권우택;권이승;이우식
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.107-111
    • /
    • 2017
  • 본 연구는 흡연시 발생되는 각종 유해오염물질을 효과적으로 저감할 수 있는 친환경 흡연부스를 제작하고, 유해물질의 제거효율 및 효과를 평가하는 것이다. 유입구-HEPA필터-전기집진기(EP)-첨착활성탄-배출구 등의 탈취설비를 갖춘 친환경 자동 흡연부스를 설계 및 제작하여, 흡연연기에 의한 유해오염물질의 제거효율을 측정 및 평가하였다. 측정방법으로는 내부의 배경농도, 설비 가동 시 배출구 농도, 10분 후 흡연부스의 농도를 측정하고, 평가항목으로는 복합악취, 일산화탄소, 미세먼지($PM_1$, $PM_{2.5}$, $PM_{10}$), 총휘발성유기화합물(TVOCs)을 대상으로 하였다. 복합악취 제거효율은 흡연부스 내부에서는 95.37%, 방지설비통과 배출구에서는 97.38%로 우수하였다. 일산화탄소 제거효율은 내부에서는 94.25%, 배출구에서는 98.32%로 나타났다. 또 흡연부스 내부에서의 미세먼지 제거효율은 98.59%이며, 배출구에서는 98.85%로 나타나 미세먼지 제거효율은 매우 우수한 것으로 나타났다. TVOCs는 흡연부스 내부에서는 $26,000{\mu}g/m^3$에서 $5,203{\mu}g/m^3$로 감소하여 79.99%의 제거효율로 나타났고, 환풍기 가동 후 방지설비 배출구에서는 $5,019{\mu}g/m^3$로 측정되어 제거효율은 80.70%로 나타났다. 따라서 본 연구를 통하여 제작, 설계된 흡연부스는 향후 소규모 작업환경 내에서도 각종 유해오염물질들을 제거하는 용도로 적용할 수 있을 것으로 생각된다.

원유유출 모의시험 챔버를 이용한 휘발성유기화합물(VOCs)의 농도변화에 관한 연구 (An Experimental Study on the VOCs Concentration Variation using a Petroleum Spill Imitation Trial Test Chamber)

  • 정진도;이동현
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.393-398
    • /
    • 2010
  • 본 연구에서는 2007년 12월 태안반도의 원유유출 사고 당시 대기중 방출된 휘발성유기화합물의 농도를 추정하고자 원유유출 모의시험 챔버를 제작하였다. 이 챔버를 이용하여 온도와 기류를 변수로 두고, 시간에 따른 총 VOCs 농도와 개별 VOCs 농도의 변화를 측정 분석 하였다. 기류가 강할수록 VOCs의 농도가 낮고 온도가 높을수록 VOCs의 농도가 높다는 것을 알 수 있었다. 또한, 총 휘발성유기화합물(TVOCs)은 원유가 유출된 직후 6일이 지나면서 초기농도 대비 90% 이상이 감소하는 것으로 나타났다.

Air Pollutant Emission Factors from Composite Wood Products Manufacturing in Korea

  • Lee, Eun-Jung;Jung, Dong-Il;Kim, Dai-Gon;Lee, Sue-Been;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.57-65
    • /
    • 2007
  • In Korea, there is a general lack of information available on air emissions from industry. The reasons for this include the lack of regulatory requirements for emission monitoring, limited information on specific industries, and difficulties in monitoring certain sources. This paper presents the first detailed air pollutant emission factors from composite wood product manufacturing in Korea. This study introduced emission factors for wood-based panels such as plywood, particle board (PB), and medium density fiberboard (MDF). The emission factors of particulate matters (PM) and hazardous air pollutants (HAPs) from MDF were higher than that from other wood products. The concentration of total volatile organic compounds (TVOCs) for hot press from wood-based panels was higher than drying or gluing processes. Emissions data from NPIP were compared to the data from the suggested emission factors in this study and the US EPA's. The data from our emission factors were closer to the observed results than the data using the US EPA's emission factor.