Abstract

Indoor air quality has been addressed as an important atmospheric environmental issue and has caught attention of the public in recent years in Korea. Good indoor air quality in classrooms favour student's learning ability, teacher and staff's productivity according to other studies. In this study, each classroom at four different schools was chosen for comparison of indoor and outdoor air quality by means of source generation types such as new constructed classroom, using of cleaning agents and purchased furniture. Temperature, relative humidity (RH), carbon dioxide $(CO_2)$, formaldehyde (HCHO), total volatile organic compounds (TVOCs) and particulate matter with diameter less than $10{\mu}m\;(PM_{10})$ were monitored at indoor and outdoor locations during lesson. HCHO was found to be the worst among parameters measured in new constructed classroom, HCHO and TVOCs was worst in classroom with new purchased furniture, and TVOCs was worst in classroom cleaned by cleaning agents, Indoor $(CO_2)$ concentrations often exceeded 1500 ppm indicating importance of ventilation. Active activity of students during break time made the $PM_{10}$ concentration higher than a lesson, Improvements and further researches should be carried out considering indoor air quality at schools is of special concern since children and students are susceptible to poor air quality.

Keywords

References

  1. 양원호, 2003, 실내공기 오염물질의 노출 및 위해성평가, 대한주택공사 주택도시, 79, 102-117
  2. Yang, W., K. Lee and M. Chung, 2004, Characterization of indoor air quality using multiple measurements of nitrogen dioxide, Indoor Air, 14, 105-111 https://doi.org/10.1046/j.1600-0668.2003.00216.x
  3. Jones, A. P., 1999, Indoor air quality and health, Atmospheric Environment, 33, 4535-4564 https://doi.org/10.1016/S1352-2310(99)00272-1
  4. 손종렬, 변상훈, 김영환, 김종혁, 조윤수, 이재영, 박윤주, 2003, 서울시 일부 학교의 실내 공기질조사 및 인식도 평가, 대한위생학회지, 18(3), 101-110
  5. 백남원, 1991, 학교환경, 한국학교보건학회지, 4, 31-38
  6. Shendell, D. G., R. Prill, W. J. Fisk, M. G. Apte, D. Blake and D. Faulkner, 2004, Association between CO2 concentrations and student attendance in Washington and Idaho, Indoor Air, 14, 333-341 https://doi.org/10.1111/j.1600-0668.2004.00251.x
  7. Rosen, K. G. and G. Richardson, 1999, Would removing indoor air particulates in children's environments reduce rate of absenteeism - A hypothesis, the Science of Total Environment, 234, 87-93 https://doi.org/10.1016/S0048-9697(99)00266-1
  8. Meininghaus, R., A. Kouniali, C. Mandin and A. Cicolella, 2003, Risk assessment of sensory irritants in indoor air - a case study in a French school, Environment International, 28, 553-557 https://doi.org/10.1016/S0160-4120(02)00063-6
  9. Daisey, J. M., W. J. Angell and M. G. Apte, 2003, Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information, Indoor Air, 13, 53-64 https://doi.org/10.1034/j.1600-0668.2003.00153.x
  10. 배윤진, 김규한, 전효택, 안주성, 1998, 실내외 환경의 분진 중 중금속 농도 -서울시 강서구, 양천구, 소재의 중학교를 중심으로-, 한국지구과학회지, 19(5), 449-460
  11. 고려대 보건과학연구소, 2005, 학교 교사내 환경위생 실태조사 중간보고서
  12. Huang, H. and F. Haghighat, 2003, Building materils VOC emissions -a systematic parametric study, Building and Environment, 38, 995-1005 https://doi.org/10.1016/S0360-1323(03)00062-3
  13. Guo, Z., 2002, Review of indoor emission source models, Part 1. Overview, Environmental Pollution, 120, 533-549 https://doi.org/10.1016/S0269-7491(02)00187-2
  14. Salthammer, T., 1997, Emission of volatile organic compounds from furniture coatings, Indoor Air, 7, 189-197 https://doi.org/10.1111/j.1600-0668.1997.t01-1-00004.x

Cited by

  1. School Indoor Air Quality and Health Effects vol.35, pp.3, 2009, https://doi.org/10.5668/JEHS.2009.35.3.143
  2. A Study on the PM10 and CO2 Concentrations at Public Places vol.16, pp.6, 2015, https://doi.org/10.5762/KAIS.2015.16.6.4335
  3. Examination of purchasing criteria through classroom formaldehyde survey result from new desks and chairs for students vol.17, pp.1, 2018, https://doi.org/10.15250/joie.2018.17.1.54