• Title/Summary/Keyword: TVOCs s

Search Result 14, Processing Time 0.023 seconds

Characteristics of TVOCs Emission Factors from Chemical and Natural Coating Materials (화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구)

  • Kim Shin Do;Kim Jeong Ho;Park Jin Soo;Lee Jeong Joo
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.487-492
    • /
    • 2004
  • Building materials are composed of very complex chemical compounds, and these indoor building materials discharge very much Volatile Organic Compounds(VOCs). We performed the environmental chamber test to investigate the Total VOCs(TVOCs) emission characteristics and emission factors about chemical and natural coating materials. As the result, we concluded that TVOCs emission are high at initial time and decreased in course of time. Natural paint was low emission level for TVOCs than chemical paint by small chamber test. The TVOCs emission factor-time profile showed a good fit with the results from the measured and predicted value.

BTX Treatment of a Petrochemical Plant by Sliding Arc Plasma (Sliding Arc Plasma를 이용한 석유공장에서의 BTX 처리효율에 관한 연구)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.65-70
    • /
    • 2015
  • This research examines the removal efficiency of benzene, toluene, xylene (BTX) and total volatile organic compounds (TVOCs) by flowing VOCs, which are generated at a petrochemical complex in the Ulsan area, in a sliding arc plasma (SAP) reactor. The SAP reactor process is composed of 5 steps and the analysis was conducted using a BTX detector and TVOC measuring instrument. The removal efficiency of BTX was better at high concentration than at low concentration and the emitted TVOC concentration increased in later steps of the reactor. In addition, the removal efficiency improved, as the flow velocity increased. The maximum permissible concentration of TVOCs in the first step was about 481 ppm and showed over 94.83% efficiency when it was operated in the 2nd step at concentrations beyond 481 ppm. Therefore, there are many factors for improving the removal efficiency of SAP reactors at low concentration and measures should be prepared according to the application method for the various types of industrial reactors.

Exposure to Ozone and TVOCs during Shipyard Welding and the Adequacy of RPE (조선소 용접작업 중 오존 및 TVOCs의 노출평가와 사용 호흡보호구의 적합성)

  • Han, Don-Hee;Kim, Dong Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.200-210
    • /
    • 2018
  • Objectives: The purpose of this study is to assess the exposure to ozone and total volatile organic compounds(TVOCs) generated during welding work at a shipyard and recommend respiratory protective equipment(RPE) adequate against these hazards. Method: Ozone was collected for about 30 minutes at two-minutes intervals using a direct reading instrument, specifically an ozone analyzer(Serinus 10, Ecotech, Australia). TVOCs were collected for about 30 minutes at three-minute intervals using a portable GC (Alpha 115, Synspec BV, the Netherlands), and were determined simultaneously by area sampling at the welding plume closest to the welder's breathing zone. The total measurements were 162 for ozone($CO_2$ welding 47, TIG 60, stick 55), and 136 for TVOCs($CO_2$ 65, TIG 50, stick 21). Based on these measurements, a literature survey was conducted to assess the adequacy of RPE. Results: Relative to Korean OEL, measurements above STEL 0.2 ppm were 23.4% for $CO_2$, 63.3% for TIG and 14.5% for stick welding. There were significant differences(p=<0.0001) among welding types. Compared with ACGIH peak exposure of 0.4 ppm for ozone, which is not applied in Korea, $CO_2$ welding exceeded it by 10.6%, TIG by 40.0% and stick by 7.3%. Although it was not feasible to compare them directly since there are no Korean OEL, TVOCs had very high levels similar to the concentrations before moving into a new apartment and about 10-20 times the indoor air quality recommendations for some individual measurements. Conclusions: As ozone removal RPE has been recommended in welding environments for a long time(Lunau, 1967), this fact was demonstrated based on the results of the on-site work environment measurements(ozone and TVOCs). In conclusion, for all welding at a shipyard, gas/vapor and particulate combination RPE are recommended. If this is not possible, it should at least be present for TIG welding.

A Study on the HCHO Grade of Architectural Material's Standard for Greenness with Consideration for Residents' Safety (거주자 안전을 고려한 친환경건축자재의 HCHO 듬급에 관한 고찰)

  • Song, Hyuk;Go, Seong-Seok;Chung, Woo-Yang
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.133-140
    • /
    • 2006
  • According to Tokyo protocol which suggests the prevention of global environmental pollution, Korean government establishes the standard of architectural materials emission consistency with best effort to decrease the environmental pollution. But many current architectural materials which are used for constructing and remodeling buildings are composed of a variety of chemicals. These include stimuli bad for the residents' health and safety and harmful discharged air polluting substances such as volatile organic compounds(TVOCs) and formaldehyde(HCHO) that in tern include a variety of carcinogen substances. These discharged substances are also researched into inducing 'sick building syndrome' which induces headache, dizziness, vomiting and concentration failure among residents. But the standard of architectural materials according to the Korean apartment provision is limited to emission factors: HCHO and TVOCs. So the aim of this study is to present a standard of functional material's emission consistency about TVOCs including glues and paints, and a certification grade for green building by instituting a materials standard for green building which has consideration for the residents' safety.

Assessment of Indoor Air Quality of Classroom in School by Means of Source Generation - Case Study (발생원에 따른 일부 학교 교실의 실내공기질 평가 사례연구)

  • Yang Won-Ho;Byeon Jae-Cheol;Kim Young-Hee;Kim Dae-Won;Son Bu-Soon;Lee Jung-Eun
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.979-983
    • /
    • 2005
  • Indoor air quality has been addressed as an important atmospheric environmental issue and has caught attention of the public in recent years in Korea. Good indoor air quality in classrooms favour student's learning ability, teacher and staff's productivity according to other studies. In this study, each classroom at four different schools was chosen for comparison of indoor and outdoor air quality by means of source generation types such as new constructed classroom, using of cleaning agents and purchased furniture. Temperature, relative humidity (RH), carbon dioxide $(CO_2)$, formaldehyde (HCHO), total volatile organic compounds (TVOCs) and particulate matter with diameter less than $10{\mu}m\;(PM_{10})$ were monitored at indoor and outdoor locations during lesson. HCHO was found to be the worst among parameters measured in new constructed classroom, HCHO and TVOCs was worst in classroom with new purchased furniture, and TVOCs was worst in classroom cleaned by cleaning agents, Indoor $(CO_2)$ concentrations often exceeded 1500 ppm indicating importance of ventilation. Active activity of students during break time made the $PM_{10}$ concentration higher than a lesson, Improvements and further researches should be carried out considering indoor air quality at schools is of special concern since children and students are susceptible to poor air quality.

Study of Smoking Booth Design for the Treatment of Hazardous Pollutants (유해오염물질 처리를 위한 흡연부스의 설계)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2017
  • The purpose of this study was to develop a Eco smoking booth that can effectively reduce hazardous pollutants generated during smoking and evaluate the efficiency and effectiveness of removing hazardous pollutants. The design and manufacture of an eco-friendly automatic smoking booth equipped with deodorizing facilities, such as inlet - HEPA filter - electrostatic precipitator (EP) - impregnated activated carbon - exhaust port, etc., and the efficiency of removing hazardous pollutants from inside and outside was measured and evaluated. The complex odor removal efficiency was 95.37% inside the smoking booth, and 97.38% at the exit of the preventive facility. The carbon monoxide removal efficiency was 94.25% in the inside and 98.32% in the outlet. In addition, the removal efficiency of particulate matter, (PM1, PM2.5, and PM10) inside the smoking booth was 98.59%, and 98.85% at the outlet. The total volatile organic compounds (TVOCs) decreased from $26,000{\mu}g/m^3$ to $5,203{\mu}g/m^3$ in the smoking booth, resulting in 79.99% removal efficiency. After the ventilator was operated, the measured effluent concentration was $5,019{\mu}g/m^3$, and the removal efficiency was 80.70%. Therefore, the smoking booth designed and manufactured through this study can be applied to the removal of harmful pollutants even in the small working environment in the future.

An Experimental Study on the VOCs Concentration Variation using a Petroleum Spill Imitation Trial Test Chamber (원유유출 모의시험 챔버를 이용한 휘발성유기화합물(VOCs)의 농도변화에 관한 연구)

  • Chung, Jin-Do;Lee, Dong-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.393-398
    • /
    • 2010
  • This study prepared and utilized an imitation trial test chamber for a petroleum spill to predict the concentration of discharged Volatile Organic Compounds in the air at the time of Tae-An peninsula's petroleum spill, which happened in December, 2007. The petroleum spill imitation trial test chamber measured and analyzed the concentration variation of total VOCs. As the ambient air velocity increased, so the concentration of VOCs decreased; and as the water temperature rose, the concentration of VOCs increased. Furthermore, it appears that total concentration of VOCs decrease by more than 90% 6 days after the initial petroleum spill compared to the initial concentration of VOCs.

Air Pollutant Emission Factors from Composite Wood Products Manufacturing in Korea

  • Lee, Eun-Jung;Jung, Dong-Il;Kim, Dai-Gon;Lee, Sue-Been;Kang, Kyoung-Hee;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.57-65
    • /
    • 2007
  • In Korea, there is a general lack of information available on air emissions from industry. The reasons for this include the lack of regulatory requirements for emission monitoring, limited information on specific industries, and difficulties in monitoring certain sources. This paper presents the first detailed air pollutant emission factors from composite wood product manufacturing in Korea. This study introduced emission factors for wood-based panels such as plywood, particle board (PB), and medium density fiberboard (MDF). The emission factors of particulate matters (PM) and hazardous air pollutants (HAPs) from MDF were higher than that from other wood products. The concentration of total volatile organic compounds (TVOCs) for hot press from wood-based panels was higher than drying or gluing processes. Emissions data from NPIP were compared to the data from the suggested emission factors in this study and the US EPA's. The data from our emission factors were closer to the observed results than the data using the US EPA's emission factor.