Solar Air Heating System Thermal Performance Simulation and Verification (태양열 외기 난방 시스템의 열성능 시뮬레이션 및 검증 연구)

  • Kang, Dong-Un;Lee, Euy-Joon;Hyun, Myung-Taek
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.152-157
    • /
    • 2001
  • UTC(Unglazed Transpired Collector) system has recently emerged as a new solar air heating technology. It is relatively inexpensive because it has not a glazed material. And it demonstrates efficient particularly for the applications in which larger wall area facilities with a high outdoor air requirement. Mathematical algorithm for UTC thermal modeling has been understood for further improvement of the system. EES and TRNSYS model of actual solar wall panel could be developed for computer simulations under other conditions. Computer models could be validated with the measured data from fixed outdoor test cell in KIER(Korea Institute of Energy Research). Major design parameters could be identified such as panel configuration and absorptivity and emissivity values for UTC design.

  • PDF

Outdoor Reset Control based on Fuzzy Algorithm for Radiant Floor Heating System (퍼지 알고리즘을 기반으로한 바닥복사 난방시스템의 외기보상제어)

  • Choi, Jong-Yo;Baek, Jae-Ho;Kim, Eun-Tai;Lee, Hee-Jin;Park, Mig-Non
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1073-1074
    • /
    • 2008
  • This paper presents outdoor reset control based on fuzzy algorithm for radiant floor heating system. We construct fuzzy system under indoor temperature and outdoor temperature. Simulation is based on TRNSYS with MATLAB. MATLAB is calculating and decide heat source using fuzzy system. Energy efficiency of Fuzzy algorithm is analyzed in term of indoor by TRNSYS System.

  • PDF

Thermal Performance of Solar Thermal System by On-Off Differential Temperature of Differential Temperature Controller (차온제어기의 On-Off 온도설정에 따른 태양열 시스템 열성능)

  • Shin, U-Cheul;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • On-off differential controller is one of the very important components which affect the system performance of the active solar thermal system. In this study, analyses were made regarding the influence of "on-off" setting temperature on the system efficiency and on the electrical consumption by circulation pump. This study was performed by experiment as well as the computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results. As a results, the turn off temperature(${\Delta}T_{off}$) is much more influence than the turn on temperature(${\Delta}T_{on}$) on the system efficiency. It is more clear and sensitivity in winter season. Finally the optimum on-off setting value and the system on-off pattern according to the several different kind of system was also represented.

Optimum Design of Thermosyphon Solar Hot Water System (자연 대류형 태양열 온수기 최적 설계에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Lee, D.G.;Kang, M.C.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 1998
  • It was compared with experimental data to verify TRNSYS Model of the thermosyphon hot water system and the various simulations were conducted to optimize the component parameters of the system. To obtain consistent simulation results the system model, which could accurately describ the thermal storage tank temperature stratification and the friction head for mass flow rate, was used. The optimization of collector parameters(collector aspect ratio, riser numbers per header unit length), thermal storage tank parameters(ratio of tank length to tank diameter, heat exchanger type), system parameters(ratio of tank volume to collector area) was simulated by TRNSYS program. The simulation results indicate that the system performance is more effected by collector aspect ratio and the ratio of tank volume to collector area than the othor parameters.

  • PDF

Thermal Performance Analysis for Optimal Operation of Solar Hot Water System (태양열 급탕시스템의 최적화 운전을 위한 열성능 분석)

  • Shin, U-Cheul;Yoon, Jong-Ho;Baek, Nam-Choon;Kwak, Hee-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.143-147
    • /
    • 2011
  • On-off differential controller is one of the very important component which has influence on the system performance of the solar hot water system. In this study, it was analysed the influence of "on-off" setting temperature on the system efficiency and the electrical consumption by circulation pump. This study was performed by computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results.

Study on the Large Scale Solar Thermal Power Plant System by Using the TRNSYS Program (TRNSYS를 이용한 대규모 태양열발전시스템 성능 연구)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Su;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.176-179
    • /
    • 2006
  • This paper describes the procedure of the basic design and transient variation of performance for a 1MWe large scale solar thermal power plant system (STPPS) by using the commercial software tool of TRNSYS. In order to simulate the transient variation of STPPS's performance, the basic design of STPPS are preceded by using the THERMOFLEX, Three different days of DNI weather data of Daejeon in 2005 are used to calculate the performance. For a high DNI data values, the general ing power of 1.1 MWe and flow rate of 1.4kg/s at $804W/m^2$ are good agreement with the basic design value of 1.0 MWe, 1.36 kg/s at $800 /m^2$. Using the other weather data of low and sudden decreasing DNI values, the results show that the output power and flow rate follow well the DNI variation. Based on the results, it is allowed to use the Program to estimate the performance of STPPS for variety of DNI data.

  • PDF

The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program (동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.

Power consumption prediction model based on artificial neural networks for seawater source heat pump system in recirculating aquaculture system fish farm (순환여과식 양식장 해수 열원 히트펌프 시스템의 전력 소비량 예측을 위한 인공 신경망 모델)

  • Hyeon-Seok JEONG;Jong-Hyeok RYU;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.1
    • /
    • pp.87-99
    • /
    • 2024
  • This study deals with the application of an artificial neural network (ANN) model to predict power consumption for utilizing seawater source heat pumps of recirculating aquaculture system. An integrated dynamic simulation model was constructed using the TRNSYS program to obtain input and output data for the ANN model to predict the power consumption of the recirculating aquaculture system with a heat pump system. Data obtained from the TRNSYS program were analyzed using linear regression, and converted into optimal data necessary for the ANN model through normalization. To optimize the ANN-based power consumption prediction model, the hyper parameters of ANN were determined using the Bayesian optimization. ANN simulation results showed that ANN models with optimized hyper parameters exhibited acceptably high predictive accuracy conforming to ASHRAE standards.

Development of Thermal Performance Analysis Program of Solar Heating System for District Heating System (지역난방 태양열시스템의 열성능 해석 프로그램 개발)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.64-69
    • /
    • 2008
  • In this study the thermal performance and economic analysis program of solar heating system for district heating was developed. This program, named SOLAN-DHS and based on TRNSYS, consisted of four modules like as user's interface for system input/output, library, and utilities and a calculating engine. SOLAN-DHS simplifies user's input data through the database of most system engineering data including weather data of 17 areas in Korea. Five different types of solar systems which can be applicable to district heating system were presented in this program. Due to the user-friendly layout, all design parameters can be changed quickly and easily for the influence on system efficiency. The reliability of SOLAN-DHS was finally verified by the experiments.

Comparison Analysis of Cooling and Heating Demand by Building Type and Region using ECO2 and TRNSYS (건물유형 및 지역조건에 따른 ECO2 및 TRNSYS의 냉난방부하 비교분석)

  • Dongjin Park;Hyunjae Lee;Jinhwan Oh;Youngsik Kwon;Jaekwang Yang;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • In Korea, it is also mandatory for most buildings to receive energy efficiency rating certification from 2020 for the purpose of reducing greenhouse gas emissions and expanding green buildings. However, the issue of the accuracy of the ECO2 program continues to be raised, and comparisons have been made with dynamic energy analysis programs in a single type of building according to a single area. However, comparisons between multiple building types and multiple areas are insufficient. Therefore, in this study, cooling and heating loads according to multiple building types and multiple areas were analyzed through ECO2 and TRNSYS programs. The regions were supposed to be Seoul, Daejeon, Gwangju, and Busan and the building types were supposed to be office buildings and apartment houses. The annual average building load values from ECO2 were higher than those from TRNSYS. Among residential buildings across the four regions, the largest discrepancy was 41.4% in Seoul. Conversely, for commercial buildings, the most significant difference in annual average loads was noted in Gwangju, at 37.9%.