• Title/Summary/Keyword: THICKNESS

Search Result 26,125, Processing Time 0.044 seconds

Anatomical Measurement of the Masseter Muscle and Surface Mapping of the Maximal Thickness Point Using Computed Tomography Analysis (전산화단층촬영 영상분석을 이용한 교근의 해부학적 계측 및 최대 두께점 피부 표지화)

  • Suh, Hyeun-Woo;Kim, Hyo-Seong;Ha, Ki-Young;Kim, Boo-Yeong;Pae, Nam-Seok;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • Purpose: Masseter muscle is an important muscle of mastication. Because it has a great influence on the shape of low facial contour, patients who have masseteric hypertrophy show square-shaped jaw appearance. As aesthetic procedures for the reduction of the masseter muscle volume, radiofrequency ablation or botulinum toxin injection is at the center of attention. Authors studied the anatomical measurement of the thickness and width of masseter muscle and the surface mapping of the maximal thickness point using computed tomography (CT) scan to identify the useful guide for the injection of botulinum toxin in masseteric hypertrophy patients. Methods: We analyzed 2 mm-thickness OMU (ostiomeatal unit) CT of 112 normal people (224 masseter muscles) taken from June 2009 to May 2010. First, we measured the thickness, width and depth of the masseter muscle from the skin surface and analysed each by side, sex and age, respectively. The distribution of the thickness of the muscle and the correlation of thickness and width of the muscle were studied also. Second, we underwent surface mapping of the maximal thickness point using CT analysis by means of checking the vertical and horizontal distance from the angle of the mandible. Results: The average thickness and width of the masseter muscle was 17.73 mm and 40.78 mm in the male patients and were 14.33 mm and 37.42 mm in the female patients. Statistically, both figures of the male patients were larger than those of the female patients. However, the depth of the muscle from the skin surface in female patients (7.37 mm) was larger than that of the male patients (6.15 mm). There were no statistical difference in side or age. The width and thickness of the masseter muscle were in the positive correlation. The location of maximal thickness point of the masseter muscle was 27.77 mm vertically and 27.68 mm horizontally in the male patients, and 25.19 mm vertically and 25.42 mm horizontally in the female patients from the angle of mandible. Conclusion: We were able to present statistical evidence of the diagnosis and treatment of the masseteric hypertrophy regarding the anatomical measurements such as the thickness and width. And the maximal thickness point of the masseter muscle may be a useful guide for the clinical procedures of botulinum toxin injection.

Assessment of NATM tunnel lining thickness and its behind state utilizing GPR survey (GPR탐사를 통한 NATM터널(무근)라이닝의 두께 분포 및 배면상태 평가)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.717-733
    • /
    • 2019
  • In this study, lining thickness distribution and its behind state (particularly, its void state) were analyzed using the GPR survey data performed on three currently operating NATM tunnels. Results of GPR analysis showed that void areas were mostly detected between concrete lining and primary support, particularly, near the crown of the tunnels. The lining thickness in the left-hand side of the tunnel was different from that of the right-hand side by 8.6~253.5 mm when measured in transverse direction. It was also found that longitudinal cracks were prevailed in the area lining thickness was sharply changed. Longitudinal thickness distribution at the crown was also studied and tested by performing 3 goodness-of-fit tests in order to find the most suitable thickness distribution. Normal distribution (or similar distribution) fit most suitably to the measured data if the measured average thickness was larger than designed one; Gamma and/or Inverse Gauss distribution fit to the measured data reasonably well if the measured average thickness was less than the designed value of thickness. Since actual lining thickness can be a potential index when assessing the state and safety of the unreinforced NATM tunnel lining, measuring of the lining thickness with GPR survey might be needed rather than assuming the thickness is always constant and same with the designed value.

Vibration Characteristics of Conical Shells with Linearly Varying Thickness (선형적으로 두께가 변하는 원추형 셸의 진동특성)

  • Yeo, D.J.;Cho, I.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.2
    • /
    • pp.35-40
    • /
    • 2008
  • This paper deals with the free vibrations of conical shells with linearly variable thickness by the transfer influence coefficient method. The classical thin shell theory based upon the Flugge theory is assumed and the governing equations of a conical shell are written as a coupled set of first order matrix differential equations using the transfer matrix. The Runge-Kutta-Gill integration method is used to solve the governing differential equation. The natural frequencies and corresponding mode shapes are calculated numerically for the conical shells with linearly variable thickness and various boundary conditions at the edges. The present method is applied to conical shells with linearly varying thickness, and the effects of the semi-vertex angle, the number of circumferential waves and thickness ratio on vibration are studied.

  • PDF

The Effect of Change in Transversus Abdominis Thickness Using Ultrasound Image during a Hip Adductor Contraction (고관절 내전근 수축이 복횡근의 두께변화에 미치는 영향)

  • Moon, Hyun-Ju;Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.287-292
    • /
    • 2011
  • Purpose :The present study invesigated the effect of changes in transversus abdominis thickness using ultrasonography during a hip adductor contraction. Methods : This study was carred out in a volunteer sample of adults (N=30) without a history of low back pain or injury. In standing position, muscle thickness measurements of transversus abdominis(TrA) were measured using ultrasonography at rest and during a hip adducor contraction. Results : TrA thickness were influenced a hip adductor during a voluntary contraction in people without LBP. TrA showed significantly greater thickness changes on a hip adductor contraction.(p=0.000) Conclusion : The results from this study showed that the hip adductor contraction improves the ability to increase change in TrA thickness. These results can be a good evidence to prevent low back pain due to hip adductor weakness or genu varum deformity of knee osteoarthritis.

An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls. (주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Ui-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

Investigation of two parallel lengthwise cracks in an inhomogeneous beam of varying thickness

  • Rizov, Victor I.
    • Coupled systems mechanics
    • /
    • v.9 no.4
    • /
    • pp.381-396
    • /
    • 2020
  • Analytical investigation of the fracture of inhomogeneous beam with two parallel lengthwise cracks is performed. The thickness of the beam varies continuously along the beam length. The beam is loaded in three-point bending. Two beam configurations with different lengths of the cracks are analyzed. The two cracks are located arbitrary along the thickness of the beam. Solutions to the strain energy release rate are derived assuming that the material has non-linear elastic mechanical behavior. Besides, the beam exhibits continuous material inhomogeneity along its thickness. The balance of the energy is analyzed in order to derive the strain energy release rate. Verifications of the solutions are carried-out by considering the complementary strain energy stored in the beam configurations. The influence of the continuous variation of the thickness along the beam length on the lengthwise fracture behavior is investigated. The dependence of the lengthwise fracture on the lengths of the two parallel cracks is also studied.

Design Sensitivity Analysis and Topology Optimization of Piezoelectric Crystal Resonators (압전 수정진동자의 설계민감도 해석과 위상 최적설계)

  • Ha Youn-Doh;Cho Seon-Ho;Jung Sang-Sub
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.335-342
    • /
    • 2005
  • Using higher order Mindlin plates and piezoelectric materials, eigenvalue problems are considered. Since piezoelectric crystal resonators produce a proper amount of electric signal for a thickness-shear frequency, the objective is to decouple the thickness-shear mode from the others. Design variables are the bulk material densities corresponding to the mass of masking plates for electrodes. The design sensitivity expressions for the thickness-shear frequency and mode shape vector are derived using direct differentiation method(DDM). Using the developed design sensitivity analysis (DSA) method, we formulate a topology optimization problem whose objective function is to maximize the thickness-shear component of strain energy density at the thickness-shear mode. Constraints are the allowable volume and area of masking plate. Numerical examples show that the optimal design yields an improved mode shape and thickness-shear energy.

  • PDF

The Effect of Wall Thickness of ZnO Nanotubes on the Ethanol Gas Sensing Performance (산화아연 나노튜브의 벽 두께에 따른 에탄올 가스 검출특성)

  • Kang, Wooseung
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.225-229
    • /
    • 2017
  • ZnO nanotubes were synthesized to investigate the effect of wall thickness on the ethanol gas sensing performance. The wall thickness of the nanotubes was varied from approximately 20 to 60 nm. Transmission electron microscopy, X-ray diffraction and SAED (Selected Area Electron Beam Diffraction) analyses showed that the synthesized nanotubes were polycrystalline structured ZnO with the diameter of approximately 200-300nm. The ZnO nanotubes sensor with an optimum wall thickness of 51.8nm showed approximately 8 times higher response, compared to that with 21.14nm wall thick nanotubes, to the ethanol concentration of 500 ppm at the temperature of $300^{\circ}C$. The wall thickness of 51.8nm was found to be a little larger than 46nm, which was theoretically derived Debye length. Along with the study of the wall thickness effect on the performance of the sensors, the mechanisms of gas sensing of the polycrystalline ZnO nanotubes are also discussed.

Fabrication and Analysis of Multilayer Ceramic Capacitors for Medium and High Voltage (중, 고압용 적층 세라믹 캐패시터 제작 및 분석)

  • Yoon, Jung-Rag;Kim, Min-Ki;Lee, Heun-Young;Lee, Serk-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.685-689
    • /
    • 2005
  • In the fabrication and design of MLCCs (Multilayer Ceramic Capacitors) with Ni inner electrode for medium and high voltage, reliability and dielectric breakdown mode have been investigated. For thickness of green sheet, the relationship between the rated voltage versus the thickness of green sheet. Increasing the thickness of green sheet increases the dielectric breakdown voltage. However, a practical limit to this linear relationship occurs at 30 urn and above. As the thickness of green sheet increased, dielectric breakdown voltage and weibull coefficient is increased, but abruptly decrease at 30 urn and 36 urn. When 24 urn of green sheet thickness, weibull coefficient and dielectric breakdown voltage were 13.58 and 70 V/um respectively. The results enabling the MLCCs to demonstrate high levels of reliability at medium and high voltage.

Analysis of Fatigue Crack Growth with Thickness Ratio in Weldments (두께比를 考廬한 鎔接部의 疲勞龜裂傳播 解釋)

  • 차용훈;방한서;김덕중
    • Journal of Welding and Joining
    • /
    • v.14 no.5
    • /
    • pp.69-77
    • /
    • 1996
  • This study aims to analyze the S. I. F. K value upon Mode I cracks in a finite-width plate of varying thickness, which is expressed in terms of width ratio ($\omega$), thickness ratio ($\beta$) and non-dimensional crack length (λ) by using the 2-dimensional finite element method. Then, by comparing the effectiveness of the results obtained by the two finite element methods, it is seen that the 2-dimensional finite element method can be used in order to analyse the S. I. F. K values upon a various thickness model. A model is developed in order to analyze the effects of initial residual stress upon the fatigue crack growth behavior in various thickness welded specimens. In this model, crack growth rate da/dN appears to be come small as the thickness ratio with the same ΔK is increased. Also, in the initial step, as ΔK is increased with crack growth rate is decreased and then increased because the repeated compressive residual stress retards crack growth rate.

  • PDF