• Title/Summary/Keyword: T3SS

Search Result 548, Processing Time 0.025 seconds

A Study on Efficiency of Water Purification of Korean Village Bangjuk[dike] as a Means of Ecological Watershed Management (생태적 유역관리 도구로써 마을방죽의 수질정화 효율성 고찰)

  • An, Byung-Chul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.90-100
    • /
    • 2012
  • This study centering on 10 village - Bangjuks analyzed multifunctionality value of village Bangjuks which have been main water treatment system in Korean traditional villages. On the basis of understanding the structure and character of components such as the well, common spring, village waterway and others which making water-flow and consisting of aquatic system in Korean traditional village Bangjuk, the conclusion as the instrumental device of social and ecological role and ecological watershed management, securing the ecosystem soundness of the damaged or deteriated aquatic ecosystem due to the industrialization and urbanization is as below; 1. The traditional village Bangjuk was environmentally friendly hydraulic system which gathers waterways of village into a point including sewage water, retains and flows out to village through agricultural waterway. Through this Bangjuk, they have managed sewage and rainfall runoff flowed out village efficiently. It is not only a detention system of water but a kind of eco-friendly system that flow out water into the rivers after reusing and filtering it. 2. Around five traditional villages and five villages after modernization, this study classified the types of village Bangjuk as three types considering geographic location, size, etc; marsh type of low swamp, high water -low rice field type of natural flow stucture, low water - high rice field type requiring artificial irrigation facility. All the five traditional villages were turned out to be marsh type of low swamp. Geoji, Sanjeri, Ma-am, Yangchon of the agricultural villages were high water-low rice filed type, and Sangchoenri village was classified low water-high rice field type. 3. This study checked up the function of water purification of village Bangjuk. In Wonteo and Geji villages affected by discharge of village sewer and domestic sewage, the efficiency of ammonia nitrogen($NH_3-N$) and total phosphorus(T-P) was 56~95%, which was high. In Sangcheonri and Sanjeri villages strongly affected by stall and farmland, the efficiency of suspended solids(SS) was 70~85%, and that of total nitrogen(T-N) and total phosphorus(T-P) was 5.3~65%. 4. A water purification system can be found out in the system of village Bangjuk that filter out village sewage and rainfall runoff flowed through the settle and filter of pollution source and denitrification of plants. Through this system of village Bangjuk, it must be used as the basic facilities for the ecological watershed management. The sewage management system of village Bangjuk as a eco-filter must be used and studied as an eco-friendly facility for the ecological watershed management around the subwatershed and catchment.

A Study on the Field Application of Intermittently Aerated Activated Sludge Process for Water Reuse System (간헐포기 활성슬러지 중수처리공정의 현장적용 연구)

  • Seo, In-Seok;Kim, Byung-Goon;Park, Seung-Kook;Kwon, Sun-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.513-521
    • /
    • 2000
  • Intermittently aerated activated sludge process was applied as a water reuse process of $70m^3/day$ for the upgrade of organic, nitrogen and phosphorus removal efficiency and clarifier performance. After application of the intermittently aeration, removal efficiency of BOD, SS, T-N and T-P were achieved 95%, 90%, 80% and 60%, respectively. Removal efficiencies in intermittently aerated process were considerably increased. comparing to those of continuously aerated activated sludge process. Also sludge rising problem in clarifier was improved. Average concentration of supplied reusing water were BOD 5 mg/L, turbidity 4 NTU and after chlorination, residual chlorine 0.4 mg/L, coliform 0 MPN/100mL. Intermittently aerated activated sludge process could be one of the best alternative process for the retrofit of conventional activated sludge process for the removal of nutrient in water reuse system.

  • PDF

The out flow a property to the non-point source pollution by the discharge varation of the branch a river in the so-yang river (소양강 지류하천의 유량변동에 따른 비점오염물질 유출특성)

  • Park, Soo-Jin;Choi, Chang-Ho;Park, Jse-Kuk;Choi, Han-Kuy
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2088-2092
    • /
    • 2009
  • 비점오염원은 면으로 분포하는 오염원으로 강우시 지표유출에 의해 유출되기 때문에 발생지점 및 발생량 추정이 어려우며, 이에 대한 처리가 어려운 실정이다. 현재 점오염원의 처리는 어는 정도 도달한 선진국에서는 비점오염원이 가장 중요한 오염원으로 대두되고 있는 실정이다. 따라서, 본 연구에서는 소양호 상류유역의 지류하천인 내린천, 인북천, 북천을 대상으로 부영영화를 일으키는 수질인자 BOD, COD, SS, T-N, T-P를 대상으로 강우량에 따른 수질농도가 변화하는 양상을 고찰하였다. 연구결과, 강우시 기간이 6월 ${\sim}$ 8월에 오염물질의 유출이 크게 발생하는 것을 알 수 있었으며, 연구지점 모두 비강우시에는 1급수의 수질상태를 보였으나, 강우시에는 3급수 이하의 수질로 악화되는 것을 알 수 있었다. 또한, 각 지류하천으로부터 유입되는 부하량을 추정하여 유역면적대비 유출량 - 오염부하량의 회귀식을 작성하였다. 끝으로, 유출량비를 이용하여 각 지류 하천의 유역면적대비 연간 총 오염유출량을 산정하였다.

  • PDF

A Study on Indicator Bacteria for Water Quality Management of Urban Artificial Lakes (도심지역 인공호의 수질관리를 위한 지표세균에 관한 연구)

  • Chu, Duk-Sung;Kwon, Hyuk-Ku;Lee, Sang-Eun;Lee, Jang-Hoon
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.299-305
    • /
    • 2007
  • Distribution of fecal pollution indicator bacteria and environmental parameter were investigated of urban artificial lakes. An average concentration of temperature, pH, SS, DO, $COD_{Mn}$, T-P, T-N, Turbidity, Chl-a were $21.5^{\circ}C$, 8.07, 116.70 mg/l, 8.66 mg/l, 2.24 mg/1, 0.52 mg/l, 1.71mg/l, 80.54 NTU, and 52.12 mg/l respectively. From the results of bivariate correlation analysis, fecal contamination indicator bacteria were found to be mutually correlated. And turbidity and suspended solid were correlated. From the results of principal component analysis, four factors were extracted. And four factors of variance explained up to 81.5 percentage. Factor 1 was pollution pattern by fecal contamination, factor 2 was physical pollution pattern by pollution source, factor 3 was natural pollution by precipitation, and factor 4 was artificial pollution pattern by organism.

The removal of nitrogen & phoshorus for the swine wastewater by VSEP membrane system (진동막 분리장치를 이용한 축산폐수의 질소.인 제거에 관한 연구)

  • 지은상;김재우;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.31-36
    • /
    • 2000
  • Conventional membrane systems was difficults to treatment for the swine waste water. Technological advances in membrane filtration systems have created opportunity for the swine wastewater to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes it possible to filter effluent streams without the fouling problem exhibited by conventional membrane systems. Various kinds of waste water occurred to and swine wastewater experiment with "VSEP" set up conventional reverse osmosis membrane (ACM-4, ESPA, BW-30). The results were as followes : Treatment efficiency for the input COD(From $332mg/{\ell}$ to $4,968mg/{\ell}$) was 98%. Treatment efficiency for the input SS(From $140mg/{\ell}$ to $4,040mg/{\ell}$) was 100%(All together). Treatment efficiency for the input T-N(From $155mg/{\ell}$ to $934mg/{\ell}$) was 97%~99.8%. Treatment efficiency for the input T-P(From $28.6mg/{\ell}$ to $132mg/{\ell}$) was 99.7% and up. ESPA membrane excels three types of reverse osmosis membranes applied VSEP in removal efficiency.

  • PDF

Analysis of Flow-Weighted Mean Concentration(FWMC) Characteristics from Rural Watersheds (농업 및 산림유역의 강우유출수 유량가중평균농도 분석)

  • Shin, Min-Hwan;Shin, Yong-Chul;Heo, Sung-Gu;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.6
    • /
    • pp.3-9
    • /
    • 2007
  • Stream flow and water quality were measured and analyzed with respect to flow-weighted mean concentrations (FWMCs) of 21 rainfall events from a forested watershed (Forest Research Watershed: FRW) and two mixed watersheds of agriculture and forest (YuPo-Ri Watershed: YPW and WolGog-ri Watershed: WGW) located in the middle of the North Han River basin. The monitoring of each watershed was one year and conducted between 2004 and 2006. YPW showed more intensive agricultural practices than WGW where traditional practices were common. The average of the 21 FWMCs were in the order of YPF>WGW>FRW and were significantly different from each other at the level of 0.05. It was shown that the land use with intensive agricultural practices produced and discharged more NPS pollutants than that with traditional practices and forest. Specially, SS concentrations from the mixed watersheds were significantly higher than those from FRW. Influencing factors on runoff were analyzed rainfall and watershed area. And rainfall intensity was greater impact on runoff than daily rainfall. Measured water quality indices were shown positive correlations among them in general. However, no significant correlation was shown between COD and nutrients(T-N and T-P).

An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant (기존 하수처리장 성능개선을 위한 NPR공정의 적용)

  • Moon, Tae Hoon;Ko, Kwang Baik;Song, Eui Yeol
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

Characteristics of NPS Pollution from a Coal Mining (가행광산 지역의 비점오염물질 유출특성)

  • Seo, Jiyeon;Shin, Minhwan;Won, Chul-hee;Choi, Yong-hun;Jung, Myung-suk;Lim, Kyoung Jae;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.474-481
    • /
    • 2010
  • This study was conducted to describe the characteristics of Non-point source (NPS) Pollution discharge from a coal mining area in Korea. The study areas is located on the Dogye site, Samchuk, Kangwon Province Coal Corporation and the Jangsung site, Taebaek, Kangwon Province Coal Corporation. The monitoring system was installed at a drainage channel and water samples and rainfall events were collected during March 2008 to February 2009. The collected water samples were analyzed with respect to SS, BOD, $COD_{Cr}$, $COD_{Mn}$, T-N, T-P, and TOC, respectively. It was observed that the runoff and water quality were largely influenced by mine drainage. Also a significant relationship was observed from the correlation between flow and water quality, flow and NPS. And estimated Event Mean Concentration (EMC), NPS pollution loads were Dogey coal mine and Taeback coal mine respectively. As the study progresses in the future, runoff and pollution loads will be updated.

Analysis of Water Quality Characteristics of the Seolma-Cheon Experimental Catchment (설마천 시험유역의 수질특성 분석)

  • Kim, Dong-Phil;Yim, Dong-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1649-1653
    • /
    • 2008
  • 오염거동에 관한 연구는 일반적으로 도시하천 및 농업지역의 하천유역에서 이루어는 것이 일반적이나, 우리나라의 약 70% 정도가 산지유역으로 작은 산지하천이 발달되어 있는 점을 고려하면, 산지 소하천 유역의 오염거동 분석은 매우 의미 있다고 본다. 본 연구 대상유역인 설마천 시험유역(경기도 파주시 적성면 소재, 한국건설기술연구원 시험유역 운영 사이트)은 계곡을 중심으로 음식점과 휴게소가 발달되어 있고 소규모 농가 및 3개 군부대가 위치하는 등 비교적 적은 오염원이 존재하는 곳이다. 최근 4개년($2003{\sim}2006$년) 자료를 이용하여 대상 유역의 상 하류 2개 지점의 동시간대의 수질자료를 바탕으로 오염거동을 모의하여 각 Segment별 오염량을 산정하고 유출부인 전적비교 지점과 실측값을 비교 하였으며, 검증된 모의값을 토대로 수문조건별 수질항목별 상 하류 관계식을 도출하였다. 본 연구 대상유역의 분석을 위해 총 10개의 실측 자료와 QUAL2E-PULS 모형의 모의를 토대로 각 Segment별 오염량을 산정한 결과 98% 이상의 정확도 높은 자료를 얻었다. 이 결과를 토대로 2개 지점간의 수문조건별 수질항목별 상 하류 관계식 도출하였으며, 전기전도도, COD, BOD, DO, pH, T-N, T-P 및 SS 순으로 $98.9{\sim}87.8%$ 정도의 높은 결정계수를 보이는 것으로 분석되었다.

  • PDF

A study on the diatomaceous earth filtration of recycling basin supernatant in the water treatment plant

  • Shin, Dae-Yewn;Park, Young-Ho;Moon, Ok-Ran;Park, Hymg-Il;Chung, Kyung-Hoon;Chin-Surk ko
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.94-97
    • /
    • 2003
  • This study performed the research about the recycling basin supernatant by pre-coat filtration in the D water treatment plant at Gwangju. Choice the prompt conditions with diatomaceous earth filtration which makes contaminant reduced in the basin supernatant. Element disk of candle used in this experiment are pore size 10$\mu\textrm{m}$(R), 20$\mu\textrm{m}$(B) and 40$\mu\textrm{m}$(Y). Diatomaceous earth are cake pore size 3.5$\mu\textrm{m}$(A), 7$\mu\textrm{m}$(B) and 17$\mu\textrm{m}$(C). The filtrate concentrations were from 0.18 to 0.92$\mu\textrm{g}$/1 of Chlorophyll-a. And then, removal rate percentage were from 78.30 to 95.57(R-A). In addition SS 80%, CODMn32% COD 61%, T-N 10% and T-P 39% on the D water treatment plant. The R(40$\mu\textrm{m}$) C(17$\mu\textrm{m}$) process can be substituted of reusing the recycled water of recycling basin supernatant view of capacity and removal rate of filtrate.

  • PDF