• Title/Summary/Keyword: T2 Measurement

Search Result 2,018, Processing Time 0.036 seconds

The Sublimation Pressure and Standard Enthalpy of Sublimation of Bismuth Triiodide ($BiI_3$에 대한 승화압과 승화 표준 엔탈피)

  • 김준학
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.7
    • /
    • pp.943-951
    • /
    • 1990
  • Steady-state sublimation vapour pressures of anhydrous bismuth triiodide have been measured by the continuous gravimetric Kundsen-effusion method from 430.0 to 558.9 K and equilibrium sublimation pressures were obtained from the steady-state data. Condensation coefficients and their temperature dependence have been derived from the effusiion measurement. Condensation coefficients ranged from 0.159 to 0.048(475 to 500K), the activation enthalpy and entropy for condensation have been obtained as -93.38kTmol-1 and -212.70JK-1mol-1. The standard sublimation enthalpy changes derived by both second(modified sigma function) and third(average enthalpy method) law methods were 138.261$\pm$0.023, 138.74$\pm$0.002kJmol-1 respectively. The standard sublimation entropy change derived by modified sigma function was 191.98$\pm$0.047 JK-1mol-1. The reliable standard sublimation enthalpy change based on a correlation of ΔgcrHom(298.15K) and ΔgcrSom(298.15K), a recommended p(T) equation has been obtained for BiI3(cr) ; 1g(p/Pa)=-C/(T/K)+5.0711g(T/K)-2.838$\times$10-3(T/K)-7.758$\times$103(K/T)2+1.4519 where p is in Pa, T in Kelvin, ΔgcrHom(298.15K) in kJmol-1 and C=(ΔgcrHom(298.15K)-8.7358)/1.9146$\times$10-2.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Estimating Diameter and Height Growth for Pinus densiflora S. et Z. Using Non-linear Algebraic Difference Equations (비선형(非線型) 대수차분(代數差分) 방정식(方程式)을 이용(利用)한 소나무 직경(直徑) 및 수고(樹高) 생장(生長) 추정(推定))

  • Lee, Sang-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.2
    • /
    • pp.210-216
    • /
    • 2001
  • Pinus densiflora S. et Z. has widely been distributed, and is one of the important main foret resources in Korea. Diameter and height growth patterns were estimated using non-linear algebraic difference equation, which requires two-measurement times $T_1$ and $T_2$. To maximize data use, all possible measurement interval data were derived using Lag and Put statements in the SAS. In results, of the algebraic difference equations applied, the Schumacher and the Gompertz polymorphic equations for diameter and height, respectively showed the higher precision of the fitting. In order to allow more precise estimation of growth than those of the basic Schumacher and the Gompertz, further refinement that combine biological realism as input into the equation would be necessary.

  • PDF

The Development of Emission Factors of Greenhouse Gas from Middle and Small-Scaled RPF Incineration Facility by Concentration Measurement and Fuel Composition (농도실측 및 연료 성분조성에 의한 중소형 RPF 소각시설의 온실가스 배출계수 개발)

  • Na, Kyung-Ho;Song, Il-Seok;Choi, Si-Lim;Yoo, Jae-In;Park, Ik-Beom;Kim, Jin-Gil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.423-434
    • /
    • 2012
  • This study was carried out to develop for the emission factor of greenhouse gas (GHG) from medium and smallscaled incineration facility using RPF which is considering as a part of renewable energy in UNFCC. The actual concentration of the exhaust gas and the fuel composition of RPF were measured for the calculation of GHG emission factor in RPF incinerators, and were compared with the IPCC guideline. The $CO_2$ and $N_2O$ emission factors by the actual concentration of exhaust gas were $2.3575{\pm}1.0070tCO_2/tRPF$ and $0.0014{\pm}0.0014tN_2O/tRPF$ respectively. Also, $CO_2$ emission factor by the RPF composition was $2.7057{\pm}0.0540tCO_2/tRPF$. The GHG emission factor per energy by the actual concentration was $83.0867{\pm}26.0346tCO_2e/TJ$ which showed higher consistency with the GHG emission factor ($80.3967tCO_2e/TJ$) of waste plastic in the IPCC guideline (2006b). The $CO_2$ and $N_2O$ emission factor calculated in this study is considered as a meaningful data for GHG emission factor of RPF incineration facility because of not being developed in ROK.

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

The Effect of Mahuang(Ephedra sinica Stapf)-Chuanwu(Aconitum carmichaeli Debx) Pharmacopuncture Treatment in Obese Patients (마황천오약침이 비만에 미치는 영향)

  • Kim, Jin-Hyuk;Shin, Min-Seop;Choi, Seok-Woo;Song, Beom-Yong;Yook, Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.26 no.5
    • /
    • pp.77-83
    • /
    • 2009
  • Objectives : We investigated the effects of Mahuang-Chuanwu Pharmacopuncture Treatment in Obese Patients by analysing Body mass index(BMI), waist measurement and weight. Methods : We investigated on 52 volunteers consisted of 24 subjects in experiment(Mahuang-Chuanwu Pharmacopuncture) group and 28 subjects in control(Normal Saline) group. The Study form was a single-blind and placebo-controlled clinical trial. 24 subjects in experiment group were injected Mahuang-Chuanwu Pharmacopuncture with additional common treatment and 28 subjects in control group were injected Normal Saline with additional common treatment with Dietic Theraphy and Exercise. We measured BMI, waist measurement and weight on 3 times : before 1st session, after first 5 sessions, and after 10 sessions. The SPSS 13.0 for Windows was used to analyze the data and the wilcoxon signed ranks test (in group), mann Whitney u t-test(between two groups) and ${\chi}^2$-test(description of number) were used to verify the result. Results : In experiment group. BMI, waist measurement and weight were significantly low at the period of after first 5 sessions and after 10 sessions. In control group, BMI, waist measurement and weight were significantly low at the period of after 10 sessions but weren't significantly low at the period of after first 5 sessions. The changes of BMI, waist measurement and weight in experiment group were significantly more than that in control group. Conclusions : The Results suggest that Mahuang(Ephedra sinica Stapf)-Chuanwu(Aconitum carmichaeli Debx) Pharmacopuncture is effective on the treatment of obesity, compared to Normal Saline.

  • PDF

On Rate of Multi-Hole Injector for Diesel Engine (디이젤 기관용 다공연료 분사 밸브의 분사율 측정)

  • Jeong, Dal-Sun;An, Su-Gil;Gwon, Gi-Rin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • Ifis recommended that the injection rate should be accurate and reliable in the input data of the performance simulation in diesel engine. Matsuoka Sin improved W. Bosch's injection ratio measurement system. Matsuoka Sin reduced length of the test pipe and set the orifice. However, it was not measured accurately to measure the injection ratio due to reflection wave. In the present thesis, the improved measurement system with combination of the conventional W. Bosch type injection ratio measurement system and Matsuoka Sin type corrected W. Bosch type was practically made. The location of orifice and throttle valve was modified and set one more back pressure valve in order to reduce the effect of reflection wave. The results according to injection condition of multi-hole nozzle are following: 1. Measurement error of injection ratio measurement system in this thesis was $\pm$ 1 %, therefore, its reliability was good. 2. The form of injetion ratio is changed from trapezoidal shape to triangle shape with increase of revolution per minute when injection amount is constant. 3. In the case of constant rpm, the initial injection ratio is almost constant regardless of the amount, meanwhile the injection period becomes longer with increase of the amount. 4. The injection pressure of nozzle isn't largely influenced with injection ratio in the case of constant injection amount and rpm, otherwise the initial injection amount is increased by 3-4% when the injection pressure is low. 5. The injection ratio isn't nearly influenced with back pressure.

  • PDF

A Study on stylistic measurement of Chogori with Museum specimens (유물실측을 통한 여자저고리의 치수연구)

  • 유송옥
    • Journal of the Korean Society of Costume
    • /
    • v.32
    • /
    • pp.21-30
    • /
    • 1997
  • Chogori the basic upper garment of korea costume occupies an important role in tra-ditional dressing and continues to be in use to the present days. Of course there has been changes in the length and line of Chogori with the flow of time based on the Ancient Yoo. This is a study of the 14 parts of Chgori based on statistical analysis by computing the practical measuements. Here the statistical analysis is a objective and quantitative of the stylistic changes in Chogori with time. In this study from the data the Mean and Standard deviation has been evaluated and periodic change is shown by graph to test the periodic change T-test Regressional analysis Index analysis has been used. The results are as follows: 1. The length of clothing has changed with time except the sleeve length. Here the length of clothing means all the other measurements ex-cept the sleeve Thus while the measurements of sleeve length has been uniquely unchanged the other measurements have influenced each other. 2. Generally the form of Chogori had the tendency towards smallness in the 19th cen-tury. But it tended to get larger in the 20th century. 3. Compared to other periods the mode of 19th and 20th century Chogori was widely ac-cepted as the Standard deviation of that period was very narrow. 4. The results seen from the regressional analysis of the Cho-sun period woman's Chogori satisfy the t-value and R-squared and thus support the regression formula presump-tion. 5. From the index analysis it is revealed that with decrease in the armhole measurement sleeve measurement and neckband; relatively same decrease in the wrist measurement; and very marked decrease in the sideline measurement.

  • PDF

The effects of GCM ankle joint therapy on Shoulder and Neck (전신조정술 발목관절치료가 어깨와 목에 미치는 영향)

  • Hyoung In-Hyouk;Ahn Mock;Bae Sung-Soo;Mun Sang-Eun;Chae Jung-Byung
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.479-487
    • /
    • 2003
  • Tje purpose of this study is to understand body as a whole concept through examining effects of distant shoulder and neck with GCM ankle joint therapy. The twenty three subject with ankle joint therapy and comparison groups without ankle joint therapy were authorized the score of before and after therapy by correspondence T-test using pump lines and tapes as instruments. The results are as follows. 1. The test group had change of shoulder in measurement 1, 2, 3 and were regarded statistically 1st measurement on left, 2nd on right.(p<.05) 2. The test group had change of neck in measurement 1, 2, 3 and were regarded statistically 2nd on left on right.(p<.05) 3. In the comparison group the comparison of shoulder height was not regarded statistically all at 1, 2 comparison on left and regarded statistically all at 1, 2 comparison on right.(p<.05) 4. In the comparison group the comparison of neck height was not regarded statistically both left and right at 1, 2 comparison.(p<.05)

  • PDF

An Analysis of the Body Measurement for Men s Clothing Design (성인 남자의 의복 설계를 위한 신체계측 분석 연구)

  • Lee, Myung-Hee;Jang, Jeong-Ah;Yang, Jin;Park, Jeong-Soon
    • The Research Journal of the Costume Culture
    • /
    • v.4 no.2
    • /
    • pp.265-275
    • /
    • 1996
  • The purpose of this study is to analysis men's measurement and index to provide the fundamental information for he clothing design which can reflect the characteristic of their bodies The items of study were composed 34 items in measurement and 3 1items in index. An anthropometric database used for this study was the 1992 national anthropometric survey of Koreans. The range of sample was 1,059 men from 25 to 55 years old. The results obtained are as follows. 1) Men showed statue to waist height was 5 to 3, statue to trochanter height was 2 to 9 and waist height to torso was 5 to 2.1. 2) We have obtained 8 factors from the result of factor analysis in index. 3) As the result of cluster analysis about somatotype, men were types tow which were contrary to each other. And as the result of t-test between type 1 and type 2, upper body (factor 5), at factors(factor2, 6), and body proportion (factor 4) were intent to each other. Therefore type 1 was peculiar about the factors of 2, 5, 6, and type 2 was about factor.

  • PDF