• Title/Summary/Keyword: T-Shaped

Search Result 820, Processing Time 0.023 seconds

Investigation on the seismic performance of T-shaped column joints

  • Chen, Changhong;Gong, He;Yao, Yao;Huang, Ying;Keer, Leon M.
    • Computers and Concrete
    • /
    • v.21 no.3
    • /
    • pp.335-344
    • /
    • 2018
  • More and more special-shaped structural systems have been widely used in various industrial and civil buildings in order to satisfy the new structural system and the increasing demand for architectural beauty. With the popularity of the special-shaped structure system, its seismic performance and damage form have also attracted extensive attention. In the current research, an experimental analysis of six groups of (2/3 scale) T-shaped column joints was conducted to investigate the seismic performance of T-shaped column joints. Effects of the beam cross section, transverse stirrup ratio and axial compression ratio on bearing capacity and energy dissipation capacity of column joints were obtained. The crack pattern of T-shaped column joints under low cyclic load was presented and showed a reversed "K" mode. According to the crack configurations, a tensile-shear failure model to determine the shear bearing capacity and crack propagation mechanisms is developed.

Hybrid Planar Inverted-F Antenna with a T-Shaped Slot on the Ground Plane

  • Jeon, Sin-Hyung;Choi, Hyeng-Cheul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.616-618
    • /
    • 2009
  • In this letter, a novel hybrid planar inverted-F antenna (PIFA) with a T-shaped slot on the ground plane is proposed. The loop structure formed by the feed line and shorting pin can be operated as a series and shunt inductance for the PIFA and the T-shaped slot antenna, respectively. The PIFA operates at a frequency of 1.75 GHz, while the T-shaped slot on the ground plane operates at 2.4 GHz by the same voltage feeding source. The height of the PIFA is 6.5 mm, and the size of an upper patch is designed to be 30 mm${\times}$16 mm. The measured relative impedance bandwidth of the PIFA and the T-shaped slot are about 12% and 21%, respectively. In addition, good antenna performance was achieved.

An Analysis of T-Shaped Forging by Upper-Bound Element Technique (상계요소법에 의한 T형 단조 해석)

  • 배원병;김영호;박재우;곽태수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.223-228
    • /
    • 1994
  • A new velocity formulation technique, which contains the advantage of UBET and the shape function of FEM, is proposed. In the proposed technique, a shape function is used to improve the unreasonableness of elemental partition and to solve the difficulty of velocity-field determination. In order to verify the effectiveness of this rechnique, T-shaped forging processes are simulated. The results are compared with these obtained by experimental measurements in T-shaped forging. In T-shaped forging, good agreements between theory and experiment are also confined.

  • PDF

A new model for T-shaped combined footings part I: Optimal dimensioning

  • Luevanos-Rojas, Arnulfo;Lopez-Chavarria, Sandra;Medina-Elizondo, Manuel
    • Geomechanics and Engineering
    • /
    • v.14 no.1
    • /
    • pp.51-60
    • /
    • 2018
  • The foundations are classified into shallow and deep, which have important differences: in terms of geometry, the behavior of the soil, its structural functionality, and its constructive systems. The shallow foundations may be of various types according to their function; isolated footings, combined footings, strip footings, and slabs foundation. The isolated footings are of the type rectangular, square and circular. The combined footing may be rectangular, trapezoidal or T-shaped in plan. This paper presents a new model for T-shaped combined footings to obtain the most economical contact surface on the soil (optimal dimensioning) to support an axial load and moment in two directions to each column. The new model considers the soil real pressure, i.e., the pressure varies linearly. The classical model uses the technique of test and error, i.e., a dimension is proposed, and subsequently, the equation of the biaxial bending is used to obtain the stresses acting on each vertex of the T-shaped combined footing, which must meet the conditions following: The minimum stress should be equal or greater than zero, and maximum stress must be equal or less than the allowable capacity that can withstand the soil. To illustrate the validity of the new model, numerical examples are presented to obtain the minimum area of the contact surface on the soil for T-shaped combined footings subjected to an axial load and moments in two directions applied to each column.

Seismic behavior of reinforced concrete T-shaped columns under compression-bending-shear and torsion

  • Ping, Chen Zong;Weiwei, Su;Yang, Yang
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.431-444
    • /
    • 2021
  • T-shaped column is usually used as side column in buildings, which is one of the weak members in structural system. This paper presented a quasi-static cyclic loading experiment of six specimens of reinforced concrete (RC) T-shaped columns under compression-flexure-shear-torsion combined loadings to investigate the effect in the ratio of torsion to moment (T/M) and axial compression ratio (n) and height-thickness ratio of flange plate (φ) on their seismic performance. Based on the test results, the failure characteristics, hysteretic curves, ductility, energy dissipation, stiffness degradation and strength degradation were analyzed. The results show that the failure characteristics of RC T-shaped columns mainly depend on the ratio of torsion to moment, which can be divided into bending failure, bending-torsion failure and shear-torsion failure. With the increase of T/M ratio, the torsion ductility coefficient increased, and in a suitable range, the torsion and horizontal displacement ductility coefficient of RC T-shaped columns could be effectively improved with the increase of axial compression ratio and the decrease of height-thickness ratio of flange plate. Besides, the energy dissipation capacity of the specimens mainly depended on the bending and shear energy dissipation capacity. On the other hand, the increase of axial compression ratio and the ratio of torsion to moment could accelerate the torsional and bending stiffness degradation of RC T-shaped columns. Moreover, the degradation coefficient of torsion strength was between 0.80 and 0.98, and that of bending strength was between 0.75 and 1.00.

Experimental Studies on Behaviors of T-Shaped Structural Walls with Different Concrete Compressive Strengths and Aspect Ratios (콘크리트 압축강도와 웨브길이 변화에 따른 T형 벽체의 거동에 관한 실험적 연구)

  • Yang, Ji-Soo;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.201-208
    • /
    • 2003
  • In domestic, bearing wall apartment building have not rectangular walls but irregular walls which are designed at walls of various cross-sectional shapes such as H-shaped, T-shaped, Box-shaped and L-shaped. In these irregular walls connected with rigid joint each other, one side walls of irregular walls is expected to show effective behavior for rigid-jointed the other side walls. Moreover, previous studies have focused on simplifying irregular walls into rectangular walls because of the complication in structural design and analysis. So studies for variables affecting behaviors of irregular walls, such as aspect ratios and compressive strength of concrete, are insufficient. The objective of this study is to evaluate the behaviors of T-shaped structural walls with different concrete compressive strengths and aspect ratios by experimental works. Results of this experimental study show that flange wall is contributed to increase the flexural strengths by the variation of concrete strengths and aspect ratios, and that it is needed to evaluate the effect width of flange wall for rational wall design.

T-Shaped DGS for CPW (CPW에 삽입된 T자형 DGS)

  • Kim Hyung-Mi;Lee Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.10 s.89
    • /
    • pp.938-943
    • /
    • 2004
  • In this paper, we propose a T-shaped DGS for CPW and provide the closed-form solutions for power loss rate, and bandwidth of the DGS. The proposed T-shaped DGS structure has a range of capacitance(C) 5.5 times wider than the dumbbell-shaped DGS structure. In addition we also analyze relations between R, L, C values of the DGS equivalent circuit and total loss rate, BW, $\omega_0$ of the DGS.

A numerical method for evaluating fire performance of prestressed concrete T bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Song, Chaojie;Hou, Wei;He, Shuanhai
    • Computers and Concrete
    • /
    • v.25 no.6
    • /
    • pp.497-507
    • /
    • 2020
  • This paper presents a numerical method for evaluating fire performance of prestressed concrete (PC) T shaped bridge girders under combined effect of structural loading and hydrocarbon fire exposure conditions. A numerical model, developed using the computer program ANSYS, is employed to investigate fire response of PC T shaped bridge girders by taking into consideration structural inherent parameters, namely; arrangement of prestressing strands with in the girder section, thickness of concrete cover over prestressing strands, effective degree of prestress and content of prestressing strands. Then, a sequential thermo-mechanical analysis is performed to predict cross sectional temperature followed by mechanical response of T shaped bridge girders. The validity of the numerical model is established by comparing temperatures, deflections and failure time generated from fire tests. Through numerical studies, it is shown that thickness of concrete cover and arrangement of prestressing strands in girder section have significant influence on the fire resistance of PC T shaped bridge girders. Increase in effective degree of prestress in strands with triangular shaped layout and content in prestressing strands can slow down the progression of deflections in PC T shaped bridge girder towards the final stages of fire exposure, to thereby preventing sudden collapse of the girder. Rate of deflection based failure criterion governs failure in PC T shaped bridge girders under most hydrocarbon fire exposure conditions. Structural inherent parameters incorporated into sectional configuration can significantly enhance fire resistance of PC bridge girders; thus mitigating fire induced collapse of these bridge girders.

Fabrication and measurement of a Weathercock-Shaped Microstrip patch Antenna with T-Slot for 5.25-GHz Band Wireless LAN (5.25GHz 무선 LAN을 위한 T-Slot Weathercock-Shaped 마이크로스트립 패치 안테나 설계 및 제작)

  • Choi Sun-Ho;Jeong Gyey-Teak;Lee Hwa-Choon;Kwak Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12A
    • /
    • pp.1183-1187
    • /
    • 2005
  • In this paper, a weathercock-shaped microstrip patch antenna for application in 5.25GHz band wireless LAN is designed and fabricated. To obtain sufficient bandwidth in VSWR<2, the T-slot is inserted on the patch, the coaxial probe source is used. The measured result of fabricated antenna obtained 350MHz or about $7.62\%$ bandwidth in VSWR<2 referenced to the center frequency, the gain of 5.25${\~}$6.70dBi. The experimental 3-dB beam width is shown to be broad across the pass band in azimuth and elevation at $80.32^{\circ}$ and $83.88^{\circ}$, in several.

Investigation on the Automatic Surface Generation for Extrusion Die of T-shaped Section using NURBS Surface and Area Mapping Method (NURBS 곡면과 면적 사상법을 이용한 T-형 압출 금형곡면의 자동생성에 관한 연구)

  • 임종훈;유동진
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.208-217
    • /
    • 2003
  • In order to construct the extrusion die surface of T -shaped sections, an automatic surface construction method based on NURBS surface and area mapping method is proposed in the present work. In the present study, a center point for area mapping is determined by introducing the mapping concept based on constant area proportionality between original billet and final product. The characteristic points of inlet profile are determined using the traditional area mapping method and the root finding numerical method. The inlet and outlet profiles are precisely described with NURBS curves using the characteristic points of entry and exit sections. For the construction of NURBS surface, an interpolation method for the pre-determined two section curves has been developed to be used in the generation of interior control points and weights. To show the validity of the proposed method, automatic die surface generation is carried out for the T-shaped section and T-shaped section with rounded corners.