• 제목/요약/키워드: T-S Fuzzy

검색결과 414건 처리시간 0.022초

Intelligent Digital Redesign Based on Periodic Control

  • Kim Do Wan;Joo Young Hoon;Park Jin Bae
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2005년도 춘계학술대회 학술발표 논문집 제15권 제1호
    • /
    • pp.378-381
    • /
    • 2005
  • This paper presents a new linear-matrix-inequality-based intelligent digital redesign (LMI-based IDR) technique to match the states of the analog and the digital T-S fuzzy control systems at the intersampling instants as well as the sampling ones. The main features of the proposed technique are: 1) the fuzzy-model-based periodic control is employed, and the control input is changed n times during one sampling period; 2) The proposed IDR technique is based on the approximately discretized version of the T-S fuzzy system, but its discretization error vanishes as n approaches the infinity. 3) some sufficient conditions involved in the state matching and the stability of the closed-loop discrete-time system can be formulated in the LMIs format.

  • PDF

A Fault Detection System Design for Uncertain Fuzzy Systems

  • Yoo, Seog-Hwan;Choi, Byung-Jae
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제6권1호
    • /
    • pp.1-5
    • /
    • 2006
  • This paper deals with a fault detection system design for uncertain nonlinear systems modelled as T-S fuzzy systems with the integral quadratic constraints. In order to generate a residual signal, we used a left coprime factorization of the T-S fuzzy system. From the filtered signal of the residual generator, the fault occurence can be detected effectively. A simulation study with nuclear steam generator level control system shows that the suggested method can be applied to detect the fault in actual applications.

An H Output Feedback Control for Uncertain Singularly Perturbed T-S Fuzzy Systems

  • 류석환;오설동
    • 한국지능시스템학회논문지
    • /
    • 제19권6호
    • /
    • pp.840-847
    • /
    • 2009
  • This paper deals with an $H_{\infty}$ output feedback controller design for uncertain singularly perturbed T-S fuzzy systems. Integral quadratic constraints are used to describe various kinds of uncertainties of the plant. It is shown that the $H_{\infty}$ norm of the uncertain singularly perturbed fuzzy system is less than $\gamma$ for a sufficiently small $\varepsilon$ > 0 if the $H_{\infty}$ norms of both the slow and fast subsystem are less than $\gamma$. Using this fact, we develop a linear matrix inequality based design method which is independent of the singular perturbation parameter $\varepsilon$. A numerical example is provided to demonstrate the efficacy of the proposed design method.

퍼지 Beppo Levi의 정리 (Fuzzy Beppo Levi′s Theorem)

  • Kim, Mi-Hye
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 춘계학술대회 학술발표 논문집 제14권 제1호
    • /
    • pp.510-514
    • /
    • 2004
  • In this paper, we introduce Fuzzy Beppo Levi's Theorem in which we use the supremum instead of addition in the expression of Beppo Levi's Theorem. That holds under the conditions which are continuity of t-seminorm ┬and the fuzzy additivity of a fuzzy measure g.

  • PDF

A Fault Detection System Design for Uncertain Fuzzy Systems

  • Yoo, Seog-Hwan
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.107-112
    • /
    • 2005
  • This paper deals with a fault detection system design for uncertain nonlinear systems modelled as T-S fuzzy systems with the integral quadratic constraints. In order to generate a residual signal, we used a left coprime factorization of the T-S fuzzy system. From the filtered signal of the residual generator, the fault occurence can be detected effectively. A simulation study with nuclear steam generator level control system shows that the suggested method can be applied to detect the fault in actual applications.

  • PDF

Fuzzy Modeling and Control of Wheeled Mobile Robot

  • Kang, Jin-Shik
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.58-65
    • /
    • 2003
  • In this paper, a new model, which is a Takagi-Sugeno fuzzy model, for mobile robot is presented. A controller, consisting of two loops the one of which is the inner state feedback loop designed for stability and the outer loop is a PI controller designed for tracking the reference input, is suggested. Because the robot dynamics is nonlinear, it requires the controller to be insensitive to the nonlinear term. To achieve this objective, the model is developed by well known T-S fuzzy model. The design algorithm of inner state-feedback loop is regional pole-placement. In this paper, regions, for which poles of the inner state feedback loop are lie in, are formulated by LMI's. By solving these LMI's, we can obtain the state feedback gains for T-S fuzzy system. And this paper shows that the PI controller is equivalent to the state feedback and the cost function for reference tracking is equivalent to the LQ(linear quadratic) cost. By using these properties, it is also shown in this paper that the PI controller can be obtained by solving the LQ problem.

입력지연을 갖는 T-S 퍼지 시스템의 관측기기반 출력궤환 안정화기 설계 (Observer-Based Output Feedback Stochastic Stabilizer for T-S Fuzzy Systems with Input Delay)

  • 이상인;박진배;주영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.840-843
    • /
    • 2003
  • 본 논문은 임의의 입력지연을 갖는 Takagi-Sugeno (T-S) 퍼지 시스템의 관측기 기반 출력궤환 제어 시스템을 논의한다. 설계된 연속시간 T-S 퍼지 관측기 시스템을 영차의 샘플/홀드 함수를 이용하여 이산시간 관측기를 설계한다. 이때 플랜트와 관측기의 출력에러가 제어기를 통하여 궤환되기 때문에 이산화 과정에서 발생한 에러를 보정할 수 있다. 여기에서 시스템의 제어 입력은 임의로 변화하는 유한개의 상태를 갖는 마코프 확률과정으로 표현한다. 생성된 시스템의 확률적 안정 가능성 조건은 선형 행렬 부등식의 형태로 표현한다. 이러한 결과를 2자유도 헬리콥터의 모델에 대한 모의실험을 통하여 효용성을 확인한다.

  • PDF

특이섭동 퍼지시스템의 H 출력 궤환제어 (An H Output Feedback Control for Singularly Perturbed Fuzzy Systems)

  • 류석환;최병재
    • 한국지능시스템학회논문지
    • /
    • 제14권3호
    • /
    • pp.316-323
    • /
    • 2004
  • 이 논문에서는 특이섭동 T-S 퍼지시스템의 $H_{\infty}$ 출력 궤환 제어기의 설계를 취급한다. 특이섭동 시스템에서 저속 부시스템과 고속 부시스템의 $H_{\infty}$ 노옴이 각각 ${\gamma}$ 보다 적다면 충분히 적은 ${\varepsilon}$>0에 대해서 특이섭동 퍼지시스템의 $H_{\infty}$ 노옴이 ${\gamma}$보다 적음을 증명한다. 이러한 사실을 이용하여 특이섭동 파라메터 ${\varepsilon}$과 무관한 선형 행렬부등식을 기반으로하는 제어기 설계법을 제시한다. 제시된 설계법의 효용성을 입증하기 위하여 수치예를 보여준다.

Fuzzy H$\infty$ Filtering for Nonlinear Systems with Time-Varying Delayed States

  • Lee, Kap-Rai;Lee, Jang-Sik;Oh, Do-Chang;Park, Hong-Bae
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제1권2호
    • /
    • pp.99-105
    • /
    • 1999
  • This paper presents a fuzzy H$\infty$ filtering problem for a class of uncertain nonlinear systems with time-varying delayed states and unknown inital state on the basis of Takagi-Sugeno(T-S) fuzzy model. The nonlinear systems are represented by T-S fuzzy models, and the fuzzy control systems utilize the concept of the so-called parallel distributed compensation. Using a single quadraic Lyapunov function, the stability and L2 gain performance from the noise signals to the estimation error are discussed. Sufficient conditions for the existence of fuzzy H$\infty$ filters are given in terms of linear matrix inequalities (LMIs). The filtering gains can also be directly obtained from the solutions of LMIs.

  • PDF

Design of T-S(Takagi-Sugeno) Fuzzy Control Systems Under the Bound on the Output Energy

  • Kim, Kwang-Tae;Joh, Joog-Seon;Kwon, Woo-Hyen
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제1권1호
    • /
    • pp.44-49
    • /
    • 1999
  • This paper presents a new T-S(Tae-Sugeno) fuzzy controller design method satisfying the output energy bound. Maximum output energy via a quadratic Lyapunov function to obtain the bound on output energy is derived. LMI(Linear Matrix Inequality) problems which satisfy an output energy bound for both of the continuous-time and discrete-time T-S fuzzy control system are also derived. Solving these LMIs simultaneously, we find a common symmetric positive definite matrix P which guarantees the global asymptotic stability of the system and stable feedback gains K's satisfying the output energy bound. A simple example demonstrates validity of the proposed design method.

  • PDF