• Title/Summary/Keyword: T$_1$ map

Search Result 460, Processing Time 0.024 seconds

Eco-friendly Production of Maize Using Struvite Recovered from Swine Wastewater as a Sustainable Fertilizer Source

  • Liu, YingHao;Rahman, M.M.;Kwag, Jung-Hoon;Kim, Jae-Hwan;Ra, Chang-Six
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.12
    • /
    • pp.1699-1705
    • /
    • 2011
  • Magnesium ammonium phosphate (MAP) was recovered from swine wastewater and the feasibility of reutilizing it as a slowly-releasing fertilizer was evaluated. Maize growth was investigated with normal and high application rates of MAP and a fused super phosphate (FSP) fertilizer. A total of 5 treatments ($T_0$ = control, $T_1$ = MAP based on 30 kg P $ha^{-1}$, $T_2$ = FSP based on 30 kg P $ha^{-1}$+urea equivalent to nitrogen of MAP applied in $T_1$, $T_3$ = MAP based on 40 kg P $ha^{-1}$, $T_4$ = FSP based on 40 kg P $ha^{-1}$+urea equivalent to nitrogen of MAP applied in $T_3$) were arranged with 3 replications. In the case of height and circumference, significant differences were found between controls and treated maize plants (p<0.01). However, no statistical differences were found between MAP- and FSP-urea treated maize. Leaf area and green biomass yield were significantly (p<0.01) higher in the treated group than control. Leaf area was also found significantly higher (p<0.01) in the higher MAP- treated group (2,374 $cm^2$ $plant^{-1}$) than other treatments. $N_2O$ emission was found to be lower in MAP treated soil than that from FSP-urea treated soil, which might be due to the slow releasing pattern of MAP. It could be assumed from the results that MAP would be an eco-friendly sustainable fertilizer source for crop production.

Construction of T$_1$ Map Image (T1 이완시간의 영상화)

  • 정은기;서진석;이종태;추성실;이삼현;권영길
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.83-92
    • /
    • 1995
  • The T1 mapping of an human anatomy may give a characteristic contrast among the various tissues and the normal/abnormal tissues. Here, the methodology of constructing T1 map out of several images with different TRs, will be described using non-linear curve fitting. The general curve fitting algorithm requires the initial trial values T1t and Mot for the variables to be fitted. Three different methods of suppling the trial T1t and Mot are suggested and compared for the efficiency and the accuracy. The curve-fitting routine was written in ANSI C and excuted on a SUN workstation. Several distilled-water phantoms with various concentrations of Gd-DTPA were prepared to examine the accuracy of the curve-fitting program. An MR image was used as the true proton density image without any random noise, and several images with different TRs were generated with the theoretical T1 relaxation times 250, 500, and 1000msec. The random noise of 1, 5, and 10% were embedded into the simulated images. These images were used to generate the T1 map, and the resultant T1 maps for each T1 were analyzed to study the effect of the random noise on the T1 map.

  • PDF

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

On the Gauss Map of Tubular Surfaces in Pseudo Galilean 3-Space

  • Tuncer, Yilmaz;Karacan, Murat Kemal;Yoon, Dae Won
    • Kyungpook Mathematical Journal
    • /
    • v.62 no.3
    • /
    • pp.497-507
    • /
    • 2022
  • In this study, we define tubular surfaces in Pseudo Galilean 3-space as type-1 or type-2. Using the X(s, t) position vectors of the surfaces and G(s, t) Gaussian transformations, we obtain equations for the two types of tubular surfaces that satisfy the conditions ∆X(s, t) = 0, ∆X(s, t) = AX(s, t), ∆X(s, t) = λX(s, t), ∆X(s, t) = ∆G(s, t), ∆G(s, t) = 0, ∆G(s, t) = AG(s, t) and ∆G(s, t) = λG(s, t).

On the continuity of the map induced by scalar-input control system

  • Shin, Chang-Eon
    • Communications of the Korean Mathematical Society
    • /
    • v.11 no.3
    • /
    • pp.695-706
    • /
    • 1996
  • In the control system $ \dot{x} = f(t,x(t)) + g(t,x(t))\dot{u}, x(0) = \bar{x}, t \in [0,T], $ this paper shows that the map from u with $L^1(m)$-topology to $x_u$ with $L^1(\mu)$-topology is Lipschitz continuous where f is $C^1$, $\mu$ is the Stieltjes measure derived from the function g which is not smooth in the variable t and $x_u$ is the solution of the above system corresponding to u under the assumption that $\dot{u}$ is bounded.

  • PDF

SPLITTING OFF T-SPACES AND DUALITY

  • Yoon, Yeon Soo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.16 no.1
    • /
    • pp.61-71
    • /
    • 2003
  • We obtain a necessary condition for splitting T-space off a space in terms of cyclic maps, and also obtain a necessary condition for splitting co-T-spaces in terms of cocyclic maps.

  • PDF

Automated Generation of Multi-Scale Map Database for Web Map Services (웹 지도서비스를 위한 다축척 지도 데이터셋 자동생성 기법 연구)

  • Park, Woo Jin;Bang, Yoon Sik;Yu, Ki Yun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.5
    • /
    • pp.435-444
    • /
    • 2012
  • Although the multi-scale map database should be constructed for the web map services and location-based services, much part of generation process is based on the manual editing. In this study, the map generalization methodology for automatic construction of multi-scale database from the primary data is proposed. Moreover, the generalization methodology is applied to the real map data and the prototype of multi-scale map dataset is generated. Among the generalization operators, selection/elimination, simplification and amalgamation/aggregation is applied in organized manner. The algorithm and parameters for generalization is determined experimentally considering T$\ddot{o}$pfer's radical law, minimum drawable object of map and visual aspect. The target scale level is five(1:1,000, 1:5,000, 1:25,000, 1:100,000, 1:500,000) and for the target data, new address data and digital topographic map is used.

Vasogenic Edema in Experimental Cerebral Fat Embolism

  • Park Byung-Rae;Koo Bong-Oh
    • Biomedical Science Letters
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2005
  • To evaluate the magnetic resonance imaging and electron microscopic findings of the hyperacute stage of cerebral fat embolism in cats and the time needed for the development of vasogenic edema. Magnetic resonance imaging was performed at 30 minutes (group 1, n=9) and at 30 minutes and 1, 2, 4, and 6 hours after embolization with triolein (group 2, n= 10). As a control for group 2, the same acquisition was obtained after embolization with polyvinyl alcohol particles (group 3, n=5). Electron microscopic examination was done in all cats. In group 1, the lesions were iso- or slightly hyperintense on T2-weighted (T2W) and diffusion-weighted (DWIs) images, hypointense on the apparent diffusion coefficient (ADC) map image, and markedly enhanced on the gadolinium-enhanced T1-weighted images (Gd-T1WIs). In group 2 at 30 minutes, the lesions were similar to those in group 1. Thereafter, the lesions became more hyperintense on T2WIs and DWIs and more hypoinfense on the ADC map image. In group 3, the lesions showed mild hyperintensity on T2WIs at 6 hours but hypointensity on the ADC map image from 30 minutes, with a tendency toward a greater decrease over time. Electron microscopic findings revealed discontinuity of the capillary endothelial wall, perivascular and interstitial edema, and swelling of glial and neuronal cells in groups 1 and 2. The lesions were hyperintense on T2WIs and DWIs, hypointense on the ADC map image, and enhanced on Gd-T1WIs. On electron microscopy, the lesions showed cytotoxic and vasogenic edema with disruption of the blood-brain barrier.

  • PDF