• 제목/요약/키워드: Swirl head

검색결과 84건 처리시간 0.027초

바닥공조시스템에서 복사온도가 열적쾌적성에 미치는 영향 (Effect of Radiative Mean Temperature on Thermal Comfort of Underfloor Air Distribution System)

  • 정재동;홍희기;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2006
  • Despite the fact that UFAD (Under Floor Air Distribution) systems have many benefits and are being applied in the field in increasing numbers, there is a strong need for an improved fundamental understanding of several key performance features of these systems. This study numerically investigates the effect of design parameters on the performance of UFAD, especially focused on thermal comfort. The design parameters considered in this study include supplied air temperature, supplied flow rate, diffuser shape, swirl, diffuser location, and floor-to-floor height. Also this study has compared UFAD with over head system, on the point of thermal comfort by evaluating PMV using radiative mean temperature, which shows how inadequate the evaluation of thermal comfort can be when radiation is neglected. Until now, the radiative temperature has been the missing link between CFD and thermal comfort, but the present study paves the way for overcoming this weakness.

  • PDF

과부하 원형맨홀에서의 손실계수 산정을 위한 실험적 연구 (An Experimental Study for Estimation of Head Loss Coefficients at Surcharged Circular Manhole)

  • 김정수;송주일;장석진;윤세의
    • 한국수자원학회논문집
    • /
    • 제41권3호
    • /
    • pp.305-314
    • /
    • 2008
  • 도시 우수 배수 시스템에서 우수 관거는 개수로 흐름 상태로 가정하여 설계되었기 때문에 맨홀에서의 에너지 손실은 일반적으로 중요하게 고려되지 않았다. 그러나 과부하흐름에서 에너지 손실은 관거의 배수능력을 저하시켜 도심지역의 침수피해를 가중시키는 요인이 된다. 그러므로 과부하 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 맨홀에 대한 문헌조사 및 현장조사를 실시하여 실험장치 제작과 실험조건을 선정하였다. 선정된 실험조건인 인버트 형상 조건(CASE A, B, C), 단차 조건(CASE I, II, III) 및 실험 유량($1.0\;{\sim}\;5.6\;{\ell}/sec$)을 변화시키면서 실험을 실시하였다. 맨홀 직경($D_m$)과 유입관경($D_{in}$)의 비($D_m/D_{in}$)가 증가할수록 손실계수가 증가하였으며, 맨홀 수심($h_m$)과 유입관거 직경($D_{in}$)의 비($h_m/D_{in}$)가 $1.0{\sim}1.5$일 때 손실계수가 가장 크게 산정되었다. 또한, CASE A, B, C의 평균 손실계수는 각각 0.45, 0.37, 0.3으로 산정되었다. 맨홀에 U자형 인버트를 설치하면, 원형 맨홀에서 에너지 손실을 저감시킬 수 있다. 또한 산정된 맨홀에서의 손실계수는 과부하흐름을 고려한 우수 관거 설계에 활용될 수 있다고 판단된다.

물냉각 고압 축소형 연소기의 설계 및 연소시험 (The Design and Hot-firing tests of a Water-cooled High Pressure Sub-scale Combustor)

  • 이광진;김종규;임병직;안규복;서성현;한영민;최환석
    • 한국추진공학회지
    • /
    • 제11권3호
    • /
    • pp.1-6
    • /
    • 2007
  • 연소기의 성능 향상 연구를 위해 3톤급 고압 축소형 연소기를 설계 제작하였다. 이 연소기는 하드웨어의 열적 손상을 방지하기 위해 막 냉각 및 열차폐 코팅 그리고 축방향 물냉각이 적용된 연소실과 37개의 동축 와류형 분사기를 갖는 연소기 헤드로 구성된다. 연소시험은 막 냉각 유량변화에 따라 설계점에서 수행되었고 시험결과 막 냉각 유량의 증가는 연소성능의 감소를 가져오지만 비슷한 막 냉각 유량이 적용된 시험의 경우 막 냉각 유량을 제외한 주 분사기의 혼합비에 따라 연소성능이 결정됨을 알 수 있었다.

7톤급 연소기용 분사기 검증을 위한 연소기 설계 및 제작 (Design and Fabrication of Thrust Chamber for Injector verification of 7 tonf-class Thrust Chamber)

  • 김종규;안규복;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.457-460
    • /
    • 2012
  • 본 연구는 7톤급 연소기용 분사기 검증을 위한 축소형 연소기의 설계 및 제작에 관한 것이다. 7톤급 연소기의 헤드부는 90개의 동축 와류형 분사기로 구성되며, 연소실은 케로신 재생냉각 일체형 연소기이다. 7톤급 연소기에 적용할 분사기로 차압 및 리세스 수를 달리한 분사기를 설계하였다. 설계된 분사기를 실물형 연소기에 적용하기 전 축소형 연소기에 먼저 적용하여 분사기 작동성 및 성능검증을 하고자 한다. 축소형 연소기는 분사기 19개로 구성되며, 연소압력 70 bar, 총 추진제 유량은 4.3 kg/s, 혼합비는 2.45이다.

  • PDF

산화제 과잉 예연소기 설계점 운영 특성 (Design Point Operating Characteristics of an Oxidizer Rich Preburner)

  • 문일윤;문인상;강상훈;하성업;이수용
    • 한국추진공학회지
    • /
    • 제17권4호
    • /
    • pp.81-88
    • /
    • 2013
  • 케로신과 액체산소를 추진제로 하는 다단연소방식 액체엔진용 산화제 과잉 예연소기를 설계하여 설계점에서 연소시험을 수행하였다. 설계된 산화제 과잉 예연소기는 산화제 일부와 연료를 혼합헤드를 통해 연소실에 공급하여 연소시키고 나머지 산화제를 연소실 재생냉각채널을 거쳐 연소실 중앙의 분사공을 통해 연소실로 주입하여 기화시키는 형태로 최종적으로 연소압 20 MPa, 혼합비 60에서 작동한다. 혼합헤드에는 단일 와류형 분사기를 벌집형태로 배열하였으며 가스 온도 균일성 향상과 연소 안정성 향상을 위한 혼합링과 터빈까지의 배관을 고려한 노즐을 장착하였다. 설계점 연소시험에서 산화제 과잉 예연소기는 높은 연소 안정성과 생성가스의 균일한 온도분포를 보였다.

보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험 (Performance Test of A Reverse-Annular Type Combustor (TS2) for APU)

  • 고영성;한영민;양수석;이대성;윤상식;최성만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.840-845
    • /
    • 2001
  • Development of a small gas-turbine combustor for 100kW class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swirler in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of 1170K, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than target value. So, we redesigned the second prototype(TS2) and conduct performance test with the critical focus on pattern factor and exit mean temperature. We adopted TS2 four variant to check the improvement of pattern factor. As the result, the pattern factors of several variants were satisfied with the performance target. Finally, We chose the TS2A variant as a final combustor for our APU model.

  • PDF

PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구 (A Study on the Flow Characteristics around Intakes within a Sump by PIV)

  • 최종웅;김정환;김경엽;김유택;이영호
    • 한국유체기계학회 논문집
    • /
    • 제5권3호
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

PIV에 의한 펌프장 흡입수조의 자유표면에서 발생하는 와의 운동특성에 관한 연구 (A study on the Flow Characteristics of a Vortex originated in the Free Surface within a Sump in a Pump Station by PIV)

  • 최종웅;김범석;이현;김유택;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.95-101
    • /
    • 2002
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a sin91e pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found within a sump of pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface due to different clearances from back-wall to vertical intake pipe with bell mouse and without. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

가솔린 직접분사식 고압선회 분사기의 분무 영역별 분무 특성 고찰 (Spray Characteristics for Specified Regions of High Pressure Swirl Injcetor in Gasoline Direct Injection Engine)

  • 송범근;김원태;강신재
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.9-16
    • /
    • 2003
  • According as the industry was developed, the pollution of the environment and atmosphere rose up to the surface. So, the focus is now concentrated on the engines of affinity for nature. And the investigators make more effort to the improvement in the performance of engines, depending to the prices of oil and the anxiety about the exhaustion of the fossil fuel go up. So the GDI engines head up for these necessities. In this experimental study, the spray flow characteristics for a commercial injector equipped in the present GDI engine were investigated, which had a strong influence on the engine performance and emissions. The experiment was performed at the injection pressures of 1, 3, 5 and 7MPa under the atmospheric condition. A PDPA system was used to specify the flow characteristics of the spray. Also, the global spray behavior classified into three regions as leading, main spray and vortex cloud region, was analyzed by using a visualization system. And the regions were compared with each other.

설계 인자에 따른 연료 과농 가스발생기의 연소 안정성 특성 연구 (A Parametric Study on Combustion Stability Characteristics of Fuel-rich Gas Generators)

  • 안규복;문일윤;서성현;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.171-176
    • /
    • 2006
  • 연료 과농 가스발생기에 대한 실험적 연구가 수행되었다. 연소 성능에 주요한 영향을 미치는 분사기 헤드에는 1.5의 리세스 수를 갖는 내부 혼합형 이중 스월 분사기 37개가 배치되었다. 본 논문에서는 연소실 길이, 직경, 그리고 교반링 등의 연소실 설계 변경에 따른 실물형 가스발생기의 연소 안정성 특성에 대하여 살펴보았다. 연소시험 결과 공진 주파수가 고주파 영역에서 생성됨에 따라 동압의 세기는 전반적으로 감소하였으나, 연소 불안정을 완전히 억제시키지는 못하는 것으로 나타났다.

  • PDF