Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.
The Akin osteotomy is a complimentary procedure in hallux valgus surgery. Surgical techniques may vary depending on the operators or fixation devices. Suture fixation, for which a removal procedure is not necessary, can often be recommended. However, there is a risk of failure due to the thin cortex of the phalanx. We describe a new technique using Ethibond suture fixation in Akin osteotomy, which can lower the risk of phalangeal cortical failure and articular cartilage irritation. First, the Akin osteotomy was performed on the proximal phalanx 5 to 6 mm distal to the first metatarsophalangeal joint. Then bone holes were drilled from dorsum to plantar parallel to osteotomy with the Kirschner wire. The final procedure involved passing the Ethibond sutures connected to a straight needle through the holes and tying it. This fixation method offers an effective and easy technique for performance of Akin osteotomy.
Proceedings of the Korean Fiber Society Conference
/
1998.10a
/
pp.227-231
/
1998
Poly(lactic acid)(PLA)는 인체내에서 재흡수성(resorbability), 분해물의 비독성, 성형물의 높은 기계적 강도 등과 같은 바람직한 특성을 가지는 생체 친화성 고분자로서 fracture fixation devices, drug delivery system 및 surgical suture 등과 같은 의료용 소재로의 응용에 관한 연구가 활발히 진행되고 있다[1-2]. (중략)
An odontoid process fracture is a serious type of cervical spine injury. This injury is categorized into three types based on the location of the fracture. Severe or even fatal neurological deficits can occur due to associated cord injury, which can result in complete quadriplegia. Computed tomography is the primary diagnostic tool, while magnetic resonance imaging is used to evaluate any associated cord injuries. These injuries can occur either directly from the injury or during transportation to the hospital if mishandled. There are two main treatment approaches: surgical fixation or external nonsurgical fixation, with various types and models of fixation devices available. In this case study, computed tomography follow-up confirmed that external fixation can yield successful results in terms of complete healing, even in cases complicated by other factors that may impede healing, such as pregnancy.
Purpose: Osteosynthesis has been recommended for treatment of Pauwels type III femoral neck fractures in young patients. However, no implant of choice has been reported so far. This study was conducted in order to compare the fixation stability of two conventional fixation methods with three different novel fixed angle devices in this type of fracture. Materials and Methods: A total of 25 composite femurs (4th Generation Saw bone; Pacific Research Laboratories, USA) corresponding to human bone were used. Pauwels type III fracture type was uniformly reproduced. Specimens were fixed with a cannulated screw, cannulated screw with cable, and Intertan nail, dynamic hip screw, and IKEY nail. Measurement of failure loads and the rotational change of the femoral head fragment was performed for evaluation of fixation stability. Results: All implants were compared with cannulated screw and dynmaic hip screw. No meaningful improvement was observed for the cannulated screw with cable compared with the cannulated screw and dynamic hip screw. Meaningful improvement in load-to-failure and y-rotation and z-rotation was observed for both the Intertan nail and IKEY nail compared with the cannulated screw. However, compared with the dynamic hip screw, only the IKEY nail showed improvement in the same profile but the Intertan nail did not. Conclusion: Among novel fixed angle devices, meaningful improvement was observed for the IKEY nail compared with conventional implants. Strengths of this implant include biomechanical stability and simplicity of surgical technique, indicating that it may be another good option for osteosynthesis of Pauwels type III femoral neck fractures.
Park, Dae-Hyun;Gwak, Heui-Chul;Kim, Jung-Han;Lee, Chang-Rak;Kwon, Yong-Uk;Choo, Hye-Jung;Park, Chul-Soon
Journal of Korean Foot and Ankle Society
/
v.24
no.2
/
pp.81-86
/
2020
Purpose: Ankle fractures with dislocations and pilon fractures at the distal tibia are usually associated with soft tissue damage caused by high-energy damage. Recently, a two-stage operation to perform internal fixation after the application of external fixation devices for stabilizing soft tissues has been accepted as the treatment of choice. This paper reports the clinical result of these injuries treated with threaded trans-calcaneal pin external fixation devices. Materials and Methods: Thirty-three patients diagnosed with ankle fractures with dislocations or tibial pilon fractures without open wounds. They underwent surgical treatment with threaded trans-calcaneal pin external fixation from January 2008 to February were enrolled in this study. This study evaluated the visual analogue scale (VAS), foot function index (FFI), and Olerud & Molander score as well as whether complications occurred. Results: The average VAS showed a meaningful decrease (p<0.001) from 7.4 before surgery to 2.6 after application of the external fixation device, and 1.4 at 12 months after surgery. The FFI also decreased significantly from 84.3 preoperatively to 20.3 at 12 months postoperatively (p<0.001). The Olerud & Molander score averaged 71.4 points, showing good clinical results. Complete bone union was observed in all patients. One patient each underwent debridement due to wound necrosis and infection in the pin insertion site. At the final follow-up, seven patients had posttraumatic ankle joint arthritis, according to a radiological examination. Conclusion: Manual reduction and external fixation using a threaded trans-calcaneal pin is a suitable surgical technique that is easy to perform and shows good clinical outcomes in stabilizing soft tissue damage in fractures and dislocations of ankle fracture or tibia pilon fractures in foot and ankle injury.
Purpose: To report the clinical results of the vascularized fibular graft in the treatment of intractable infected nonunion of femur. Materials and Methods: We reviewed 3 patients who were performed vascularized fibular graft in treated for intractable infected nonunion of femur. They had received an average of 5.6 times($4{\sim}8\;times$) surgical treatment at different hospitals. 1 case was of a infected nonunion in a fracture treated with internal fixation, the fracture having occurred after resection of a malignant tumor and transplantation of pasteurized autologous bone. 2 cases occurred after internal fixation in closed fractures. Surgical treatment was performed an average of 4 times($3{\sim}5\;times$) at our hospital and in all of the cases debridement of necrotic tissue and sequestrectomy. And vascularized fibular graft was performed. In all cases unilateral external fixation devices were used, of these, 1 case was changed into internal fixation. The final conclusion was made by assessment of functional outcomes and complications according to the standards of Paley. Results: As a result, in all of the cases bone union was achieved, and in the last follow up the functional results were excellent in 2 cases and good in 1 case. There were not presented leg length discrepancy of more than 2 cm, and further loss of knee joint motion. After previous treatment, average 23.3 months($16{\sim}30\;months$) was taken to eliminate infection and achieve complete bone union via vascularized fibular graft in our hospital. Conclusion: In treatment of intractable infected nonunion of femur, fairly good results can be expected after firm fixation, through debridement and vascularized fibular graft.
Kim, Do Young;Lee, Jun Hyuck;Park, Jung Hyun;Cho, Jaeho
Journal of Korean Foot and Ankle Society
/
v.20
no.4
/
pp.176-181
/
2016
Purpose: The purpose of this study was to evaluate the clinical and radiologic outcome of syndesmosis fixation using TightRope$^{TM}$ (Arthrex, Naples, FL, USA) in acute syndesmosis injuries. Materials and Methods: Twenty-five consecutive patients with acute syndesmosis injuries, treated using TightRope$^{TM}$, were reviewed. Patients were evaluated preoperatively and at the last follow-up (at least 12 months postoperatively). Clinical outcomes were assessed using American Orthopaedics Foot and Ankle Society (AOFAS) ankle-hindfoot score and self-subjective satisfaction survey. Three radiologic parameters were evaluated two times at the preoperative and final follow up from the nonweightbearing ankle anteroposterior radiographs. Results: The mean AOFAS ankle-hindfoot score was 95.5 at the final follow-up. According to the satisfaction survey, 21 patients chose excellent, and four patients chose good. All radiologic parameters, including the mean tibiofibular clear space, mean tibiofibular overlap, and mean medial clear space on nonweightbearing ankle anteroposterior view, significantly improved after surgery. Complications occurred in only one patient who experienced knot irritation with infection. Conclusion: The short-term surgical results of syndesmosis fixation using TightRope$^{TM}$ were good to excellent, both clinically and radiographically. These results suggest that the fixation using TightRope$^{TM}$ is a valid option for acute syndesmosis injury.
Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.
Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.