• 제목/요약/키워드: Surge protective device

검색결과 62건 처리시간 0.022초

보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰 (Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

인청동 스위칭 모듈을 이용한 전력계통 및 전자기기 내부회로의 MOV 열폭주 방지와 안전성 개선 (Thermal Runaway Prevention of MOV and Safety Improvement of Power Line System and Internal Electronic Device Circuit Using a Phosphorous Switching Module)

  • 김주철;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.75-79
    • /
    • 2011
  • The MOV(Metal Oxide Varistor), a voltage limiting element, has been installed in the SPD(Surge Protective Device) or inside the internal circuit of an electronic appliance for protection of the electric power system and electronic device against electrical surge. Such an MOV is exposed, however, to the risk of the thermal runaway resulting from excessive voltage and deterioration. In this paper, a reciprocal action has been tested and analyzed using a phosphorus bronze switching module and the low-temperature solder. And a short current break characteristic test linked with the circuit breaker has been performed to limit the inrush current when the MOV breaks down. It has been proven that the phosphorus bronze switching module installed inside the internal circuit can improve the safety of the power line system and the electronic device.

보호거리에 따른 전압제한형 SPD의 보호효과에 대한 시뮬레이션기법 (Simulation Method on the Protection Effects of Voltage-Limiting Type SPDs Associated with the Protective Distance)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a method of simulating the protection effects of surge protective devices(SPDs) depending on the protective distance and types of input impedance of load to be protected. In order to analyze the protective performances of voltage-limiting type SPDs associated with the reflection and oscillation phenomena, the terminal voltage across load being protected and the residual voltage of SPDs were simulated by using EMTP model as functions of the protective distance and types of input impedance of loads. As a consequence, SPDs should be installed by taking into account the protective distance and input impedance of loads to achieve reliable protection of electrical and electronic equipment from lightning and switching surges. It is expected that the simulation method proposed in this paper could be practically used in design for installing SPDs in low-voltage distribution systems.

전자통신설비의 SPD 소손사례 및 열화진단기법 분석 (Survey of Damage Cases for Surge Protective Devices Installed Electrical Communication Systems and Analysis of Degradation Diagnosis Method)

  • 임종욱;이재영;권준혁
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.15-18
    • /
    • 2009
  • In recent years electric devices and telecommunication facilities were often damaged by surge generated lightning discharge. When the service was interrupted by failure of electrical devices due to surge the social loss is very enormous. Therefore in order to protect electrical systems against lightning, SPDs(Surge protective device) have been used But damaged SPDs often make some troubles like fire and interrupt of service. In this work, 3rd harmonic leakage current defection method was applied as the diagnosis of SPD degradation and the effectiveness of this method was verified by field survey.

  • PDF

Coordination between Voltage-Limiting Surge Protective Devices in Surge Currents Caused by Direct Lightning Flashes

  • Shin, Hee-Kyung;Lee, Jae-Suk
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.116-125
    • /
    • 2015
  • This paper presents experimental results obtained from actual installation conditions of surge protective devices (SPDs), with the aim of understanding the coordination of cascaded Class I and Class II SPDs. This paper also proposes effective methods for selecting and installing coordinating cascaded SPDs. The residual voltage of each SPD and the energy sharing of an upstream Class I tested SPD and a downstream Class II tested SPD were measured using a $10/350{\mu}s$ current wave. In coordinating a cascaded voltage-limiting SPD system, it was found that energy coordination can be achieved as long as the downstream SPD is a metal oxide varistor with a higher maximum continuous operating voltage than the upstream SPD; however, it is not the optimal condition for the voltage protection level. If the varistor voltage of the downstream SPD is equal to or lower than that of the upstream SPD, the precise voltage protection level is obtained. However, this may cause serious problems with regard to energy sharing. The coordination for energy sharing and voltage protection level is fairly achieved when the cascaded SPD system consists of two voltage-limiting SPDs separated by 3 m and with the same varistor voltage.

선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법 (Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor)

  • 정태훈;김용성;박근보;이승일
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.93-102
    • /
    • 2018
  • 본 논문은 뇌격전류에 따른 저압 배전계통의 전자식 전력량계 및 배전 패널의 통신설비와 전원장치를 보호할 목적으로 사용하는 서지보호장치(SPD)에 관한 것이다. 서지보호장치(SPD)는 접속방식에 따라 1-포트 서지보호장치(SPD)와 감결합 요소를 포함한 2-포트 서지보호장치(SPD)로 구분된다. 뇌격전류에 대한 내부 시스템의 보호는 협조된 서지 보호체계를 이루는 계통적인 접근이 필요하다. 이에 대응하기 위해 이론적인 검토를 통해 피뢰구역(LPZ) 정의에 대한 고찰 및 해석을 진행하였다. 뇌서지에 의한 뇌격전류는 상당히 크기 때문에 하나의 서지보호장치(SPD)로 방호하기에는 한계가 발생하며, 이를 해결하기 위해 다단의 종속적으로 서지보호장치(SPD)를 설치하게 된다. 본 논문에서는 전력계통에 있어 한전계통에 연계되는 Incoming side가 아닌 건물 내에 설치되는 분기형 배전패널 내부의 전자식 전력량계 및 각종 통신(제어)설비를 보호할 목적으로 한전계통이 연계되는 MOF 단에 설치되는 LPZ0에 해당하는 피뢰기(LA, SA)와 보호협조를 이루는 LPZ1과 LPZ2의 경계영역에 설치하는 저압 배전계통용 II등급 서지보호장치(SPD)에 대해 설계를 하였다. 또한 감결합 요소가 없고, 부하 전류를 흘릴 수 있는 직렬 접속 방식의 1-포트 서지보호장치(SPD)에 대한 최적의 설계 방안을 도출하고 실험을 통해 기존의 방식과 비교하여 성능 개선과 관련한 검증을 실시하였다.

전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과 (REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods)

  • 이수봉;이복희;길형준
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.90-99
    • /
    • 2004
  • 고도 정보화 사회의 발달과 함께 정보통신 설비는 빠른 전송속도를 필요로 하며, 지능형 산업설비와 행정, 금융, 교통시스템과 같은 사회시스템은 집적회로와 초소형 반도체로 구성되므로 원격감시, 조작에 의해 점차적으로 자동화 되어가고 있다. 이와 같은 현대의 초소형 전자회로는 뇌 서지에 의해 흔히 손상을 입을 수 있으며, 뇌 과전압으로부터 전자회로의 보호에 관심이 집중되고 있다. 본 논문은 일반주택에서 뇌 서지로부터 초소형 컴퓨터와 같은 전자기기의 효과적인 보호방법을 제안하기 위하여 전원계통의 접지방식에 따른 서지보호기의 보호효과를 실험적으로 분석하였다. 또한 서지보호기의 효과적인 설치방법을 조사하고 제안하였다. 기존의 설비에 추가적으로 서지보호기를 설치하는 것은 서지보호기까지의 긴 접속선으로 인한 인덕턴스 때문에 높은 잔류전압이 나타난다. 서지보호기의 설치에 있어 두 접속선을 꼬는 방법이 급격하게 상승하는 과도과전압에 매우 효과적이다.