• 제목/요약/키워드: Surface resistivity

검색결과 1,000건 처리시간 0.024초

고분자 복합재료의 표면 열화 현상과 전기적 특성에 관한 연구 (A Study on the Surface Degradation Phenomena and Electrical Properties of Polymer Composite Materials)

  • 박재세;임경범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.75-78
    • /
    • 2002
  • In this paper, we investigated the change of wettability, surface potential decay and surface resistivity caused by thermal-treated and plasma-treated FRP respectively for finding out the influence of electrical characteristics on the surface of polymer composites. For the change of wettability, the contact angle of thermal-treated specimen with the high temperature of 200$^{\circ}C$ increased. But that of plasma-treated specimen decreased. The characteristic of surface potential decay shows the tendency of the remarkable decrease on plasma-treated specimens, but no difference on thermal-treated specimen compared with untreated one. Also, for the surface resistivity, it shows the same trend compared with the change of contact angle. We can conclude that the degradation phenomena of epoxy surface are dominated by the induction of hydrophilicity and hydrophobicity.

  • PDF

무안군 카르스트 지역의 지하공동 탐지를 위한 전기비저항 탐사 기술 적용 (Application of Resistivity Technique for Identifying Cavities Near Surface in Karst Area, Muan-gun, South of Korea)

  • ;박삼규;송영수;김정호
    • 지구물리와물리탐사
    • /
    • 제11권4호
    • /
    • pp.368-372
    • /
    • 2008
  • 이 연구는 카르스트 지역에서 발생하는 연약층 또는 지하 석회암 공동의 영상화를 위한 지표 전기비저항 탐사의 유용성을 파악하고자 수행되었다. 연약층 또는 공동은 잠재적인 위험성을 가지고 있으며, 이들은 도로 및 건축물의 붕괴를 야기한다. 따라서 이 연구에서는 이미 지반침하가 있었음이 보고된 바 있는 전남 무안군 영월리에 있는 한 도로를 따라 2-3차원 전기비저항 탐사를 수행하여 지반 침하 현상을 조사하였다. 이 지역의 쌍극자배열 전기비저항 탐사 결과, 풍화된 표토층과 연약층 또는 공동 그리고 기반암이 뚜렷이 구분되어 나타났으며, 또한 여러 곳의 저비저항 이상대가 나타났는데 이는 점토로 충전된 공동으로 시추결과 확인되었다. 아울러 시추 결과와 전기비저항 탐사 결과는 매우 일치함을 알 수 있었다. 따라서 지반 침하를 평가하는 데 있어 전기비저항 탐사를 통한 지하영상화 작업이 매우 높은 분해능을 가짐을 알 수 있었으며 또한 지반 침하 지역을 조사하고 이를 평가함에 있어 $2{\sim}3$차원 전기비저항탐사가 매우 유용함을 확인할 수 있었다. 이러한 탐사 결과를 바탕으로 연구지역 주변의 재해 취약정도를 작성하였다.

첨가제에 의한 구리 박막의 표면형상과 물성변화 (Effect of Additives on the Physical Properties and Surface Morphology of Copper Foil)

  • 우태규;박일송;박은광;정광희;이현우;설경원
    • 대한금속재료학회지
    • /
    • 제47권9호
    • /
    • pp.586-590
    • /
    • 2009
  • The effects of additives on the surface morphology and physical properties of copper electrodeposited on polyimide(PI) film were investigated here. Two kinds of additives, an activator(additive A) and a leveler(additive B),were used in this study. Electrochemical experiments, in conjunction with scanning electron microscopy(SEM), X-ray diffraction(XRD) and a four-point probe, were performed to characterize the morphology and mechanical characteristics of copper electrodeposited in the presence of the additives. The surface roughness, crystal growth orientation and resistivity could be controlled using various quantities of additive B. High resistivity and lower peel strength were observed on the surface of the copper layer electroplated onto the electrolyte with no additive B. However, a uniform surface, lower resistivity and high flexibility were obtained with a combination of 20 ppm of additive A and 100 ppm of additive B.

3차원 전기비저항 역산 방법을 이용한 삼보 광산에서 금광 탐사 (Application of Gold Exploration Using Three-dimensional Resistivity Inversion in Sambo mine)

  • 박종오;김희준;송무영;유영준
    • 지질공학
    • /
    • 제15권1호
    • /
    • pp.19-27
    • /
    • 2005
  • 전라남도 무안군 해제 면에 위치한 삼보광산은 편마암류 및 유문암내에 발달한 열극에 열수가 충전하여 형성된 열극 충전광산이다. 시추자료에서 얻은 분석 품위는 금이 0.05~10.9 g/t 이하, 은이 0.05~389 g/t 이하로 부분적으로 금ㆍ은 광화작용이 인지되었다. 본 연구는 지표에서의 쌍극자, 슐럼버저 및 웨너 배열을 이용한 전기비저항 탐사와 시추공에서의 전기비저항 토모그래피 탐사를 복합하여 삼보광산에서 광화대의 분포 및 이와 관련된 지질구조를 파악하고자한다. 3차원 전기비저항 역산의 결과는 광화대가 지표부터 약 80m 심도까지 30m의 폭을 가지며, N10°~20°E의 방향으로 240m 연장되어 있음을 보여준다. 전기비저항 영상에서 얻어진 1,000ohm-m이하의 전기비저항 값은 시추 자료에서 확인된 금ㆍ은 광화작용이 인지된 구간 및 연약대 구간과 거의 일치하였다.

rf 마그네트론 스퍼링에 의하여 증착된 TiN 박막의 물성에 대한 증착변수의 영향 (Effect of Deposition Parameters on the Properties of TiN Thin Films Deposited by rf Magnetron Sputtering)

  • 이도영;정지원
    • Korean Chemical Engineering Research
    • /
    • 제46권4호
    • /
    • pp.676-680
    • /
    • 2008
  • Radio-frequency (rf) 마그네트론 스퍼터링법을 이용하여 $SiO_2(2000{\AA})/Si$ 기판위에 TiN 박막이 증착되었다. $N_2/Ar$ 혼합가스에서 $N_2$ 가스의 농도, rf power, 공정압력 등을 변화시켜서 TiN 박막이 증착되었고 증착된 박막의 증착속도, 전기저항도 및 표면의 거칠기 등이 조사되었다. $N_2$ 가스의 농도가 증가함에 따라서 증착속도는 감소하였고 저항도는 증가하였으며 표면의 거칠기는 감소하였다. rf power가 증가함에 따라서 증착속도는 증가하였지만 저항도는 감소하였다. 증착압력의 증가에 따라서 증착속도는 큰 변화가 없었지만 저항도가 급격히 증가하였으며, 1 mTorr의 압력에서 $2.46{\times}10^{-4}{\Omega}cm$의 저항도를 갖는 TiN 박막이 얻어졌다. 박막의 증착속도와 저항도는 상관관계가 있는 것이 관찰되었고 특히 증착압력이 박막의 저항도에 가장 큰 영향을 미치는 것을 알 수 있었다.

Electrical and Hydraulic Characteristics of An Alluvial Bed under the Influence of Pumping and Rainfall

  • Woo-Ri Lim;Nam-Hoon Kim;Samgyu Park;Jae-Yeol Cheong;Se-Yeong Hamm
    • 한국지구과학회지
    • /
    • 제45권4호
    • /
    • pp.363-376
    • /
    • 2024
  • Alluvial beds are intimately associated with electrical properties related to soil types, including clay mineral content, porosity, and water content. The hydraulic property governs water movement and storage in alluvial beds. This study revealed electrical resistivity and hydraulic properties in space and time in relation to the hydrogeological data, groundwater pumping, and rainfall infiltration into the alluvial bed located in Daesan-myeon, Changwon City. An electrical resistivity survey with electrode spacings of 2 and 4m using a dipole-dipole array indicates that electrical resistivity changes in the alluvial bed depend on groundwater pumping and rainfall events. Additionally, rainfall infiltration varies with hydraulic conductivity in the shallow zone of the alluvial bed. The 2 m electrode spacing survey confirms that electrical resistivity values decrease at shallow depths, corresponding with rainfall and increased water content in the soil, indicating rainfall infiltration approximately 1-2 m below the land surface. The 4m electrode spacing survey reveals that hydraulic conductivity (K) values and electrical resistivity (ρ) values display an inverse relationship from the surface to the water table (approximately 9 m) and at deeper levels than the water table. Notably, ρ values are impacted by pumping around the depth of the water table at 9 m. This study suggests that time-lapsed electrical resistivity surveys in space and time could be effective tools for detecting the impact of rainfall and pumping, as well as hydraulic conductivity in shallow alluvial beds.

제조 조건에 따른 Polyaniline의 전기적 성질 (Electrical Properties of Polyaniline according to Preparation Conditions)

  • 김언령;김태영;이보현;김종은;서광석;배종현
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.215-222
    • /
    • 2001
  • Polyaniline-Camphorsulfonic Acid Emeraldine Salt(PANI-CSA ES) was prepared by doping Polyaniline Ermeralidine Base(PANI EB) with DL-10-Camphorsulfonic Acid(CSA). PANI-CSA ES was solved in an organic solvent by ultrasonification for different periods of time and its surface resistivity was measured. Several PANI-CSA ES solutions solved in different organic solvents were prepared and their surface resistivities were measured. Thermal stability of film casted with PANI-CAS ES solution in m-cresol was estimated by measuring its surface conductivity and the content of this moisture and organic solvents. PANI-CSA ES was blended with different polymeric binders to improve its physical properties and the surface resistivities of several kinds of PANI-CSA ES blends were measured as a function of the content of PANI-CSA ES. PANI-CSA ES polymerized by 1-step oxidative polymerization was prepared and its surface resistivity was measured.

  • PDF

무전해 구리 도금액에서 착화제가 접합력에 미치는 영향에 대한 고찰 (Effect of Complexing Agents on Adhesion Strength between Electroless Copper Film and Ta Diffusion Barrier)

  • 이창면;전준미;허진영;이홍기
    • 한국표면공학회지
    • /
    • 제47권4호
    • /
    • pp.162-167
    • /
    • 2014
  • The primary purpose of this research is to investigate how much the complexing agent in electroless Cu electrolytes will affect adhesion strength between copper film and Ta diffusion barrier for Cu interconnect of semiconductor. The adhesion strength using rochelle's salt as complexing agent was higher than the case of using EDTA-4Na. Effect of complexing agent on adhesion strength and electrical resistivity was studied in crystal structural point of view.

방전처리에 따른 Poly(ethylene terephthalate) 필름의 표면특성에 관한 연구 (A Study on the Surface Properties of Poly(ethylene terephthalate) films by Discharge Treatment)

  • 임경범;이백수;이상희;황명환;박구범;박종관;김영일;임헌찬;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1587-1589
    • /
    • 2000
  • In this paper the weight loss, surface potential decay, surface resistivity and dielectric constant are measured to investigate the surface properties, insulation characteristic changes of PET film according to the discharge treatment. As a result of the test, up to the 10[min] the surface potential decay and surface resistivity have increased. Also, from the result of dielectric constant has decreased. On the other hand, the insulation characteristic of PET film have decreased after 10[min] in the discharge treatment.

  • PDF

Carbon black-Polymer 복합재료의 전도임계 현상에 대한 고찰 (A study on the conductive critical behavior of Carbon black-polymer Composites)

  • 김한성;김재오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.508-510
    • /
    • 1987
  • The variation electrical resistivity of Carbon black filled polymers with volume percent of carbon black was investigated. The relationships between the surface tension of polymer and dispertion effect of carbon black were studied to find the steep drop of electrical resistivity. The critical volume percent of carbon black increased with the increasing surface tension of polymer. The PTC intensity decreased with the increasing volume percent of carbon black.

  • PDF