• Title/Summary/Keyword: Surface Measurement

Search Result 4,997, Processing Time 0.033 seconds

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

A Simple Method Using a Topography Correction Coefficient for Estimating Daily Distribution of Solar Irradiance in Complex Terrain (지형보정계수를 이용한 복잡지형의 일 적산일사량 분포 추정)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Accurate solar radiation data are critical to evaluate major physiological responses of plants. For most upland crops and orchard plants growing in complex terrain, however, it is not easy for farmers or agronomists to access solar irradiance data. Here we suggest a simple method using a sun-slope geometry based topographical coefficient to estimate daily solar irradiance on any sloping surfaces from global solar radiation measured at a nearby weather station. An hourly solar irradiance ratio ($W_i$) between sloping and horizontal surface is defined as multiplication of the relative solar intensity($k_i$) and the slope irradiance ratio($r_i$) at an hourly interval. The $k_i$ is the ratio of hourly solar radiation to the 24 hour cumulative radiation on a horizontal surface under clear sky conditions. The $r_i$ is the ratio of clear sky radiation on a given slope to that on a horizontal reference. Daily coefficient for slope correction is simply the sum of $W_i$ on each date. We calculated daily solar irradiance at 8 side slope locations circumventing a cone-shaped parasitic volcano(c.a., 570m diameter for the bottom circle and 90m bottom-to-top height) by multiplying these coefficients to the global solar radiation measured horizontally. Comparison with the measured slope irradiance from April 2007 to March 2008 resulted in the root mean square error(RMSE) of $1.61MJ\;m^{-2}$ for the whole period but the RMSE for April to October(i.e., major cropping season in Korea) was much lower and satisfied the 5% error tolerance for radiation measurement. The RMSE was smallest in October regardless of slope aspect, and the aspect dependent variation of RMSE was greatest in November. Annual variation in RMSE was greatest on north and south facing slopes, followed by southwest, southeast, and northwest slopes in decreasing order. Once the coefficients are prepared, global solar radiation data from nearby stations can be easily converted to the solar irradiance map at landscape scales with the operational reliability in cropping season.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

A Study on a Quantitative Method in Estimating Forest Effects for Streamflow Regulation (II) - Mainly Dealing with Application of Coefficient for Slope Roughness - (삼림이수기능(森林理水機能)의 정량적(定量的) 평가방법(平價方法)에 관한 연구(硏究)(II) - 조도계수(粗度係數)의 응용(應用)을 중심(中心)으로 -)

  • Lee, Heon Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.4
    • /
    • pp.337-345
    • /
    • 1992
  • In this research, a kinematic wave model was applied for the runoff analysis, Regulation of streamflow was estimated by the calibration of roughness coefficient as a parameter. The data analyzed were obtained from Ananomiya and Shirasaka experimental basins at Tokyo University Forest in Aichi. Estimation methods and characteristics of roughness coefficient as a evaluation method of hydrological function of forest are summarized as follows ; 1. Roughness coefficient($N_s$) indicates the resistance of hillslope to the flowing water of surface runoff. There exists an hypothesis that resistance of hillslope to flowing water increase with the growth forest and development of the $A_o$ layer. 2. Roughness coefficient($N_s$) was estimated by the parameter when the stream direct runoff was calculated by using the kinematic wave. 3. Secular change of '$N_s$' in ananomiya has a curve which has an upper limit and increases exponentially near the limit. The curve quickly increased from 1935 to 1945 when results of afforestation for erosion control were thought to be effective. On the other hand, slight increase of '$N_s$' in Shirasaka indicates that there was not such a big change in the surface of soil layer. 4. The increase of '$N_s$' was related with decrease of direct runoff and increase of base flow. It was recognized that the rate of direct runoff decreased with the improvement of forest physiognomy and the rate of base flow was increased. But absolute value of water runoff per one storm decreased in chronological order.

  • PDF

Recent Variations of UV Irradiance at Seoul 2004~2010 (서울의 최근 자외선 복사의 변화 2004~2010)

  • Kim, Jhoon;Park, Sang Seo;Cho, Nayeong;Kim, Woogyung;Cho, Hi Ku
    • Atmosphere
    • /
    • v.21 no.4
    • /
    • pp.429-438
    • /
    • 2011
  • The climatology of surface UV radiation for Seoul, presented in Cho et al. (1998; 2001), has been updated using measurement of surface erythemal ultraviolet (EUV) and total ultraviolet (TUV) irradiance (wavelength 286.5~363.0 nm) by a Brewer Spectrophotometer (MK-IV) for the period 2004~2010. The analysis was also carried out together with the broadband total (global) solar irradiance (TR ; 305~2800 nm) and cloud amount to compare with the UV variations, measured by Seoul meteorological station of Korean Meteorological Agency located near the present study site. Under all-sky conditions, the day-to-day variability of EUV exhibits annual mean of 98% in increase and 31% in decrease. It has been also shown that the EUV variability is 17 times as high as the total ozone in positive change, whereas this is 6 times higher in negative change. Thus, the day to day variability is dominantly caused rather by the daily synoptic situations than by the ozone variability. Annual mean value of daily EUV and TUV shows $1.62kJm^{-2}$ and $0.63MJm^{-2}$ respectively, whereas mean value of TR is $12.4MJm^{-2}$ ($143.1Wm^{-2}$). The yearly maximum in noon-time UV Index (UVI) varies between 9 and 11 depending on time of year. The highest UVI shows 11 on 20 July, 2008 during the period 2004~2010, but for the period 1994~2000, the index of 12 was recorded on 13 July, 1994 (Cho et al., 2001). A 40% of daily maximum UVI belongs to "low (UVI < 2)", whereas the UVI less than 5% of the maximum show "very high (8 < UVI < 10)". On average, the maximum UVI exceeded 8 on 9 days per year. The values of Tropospheric Emission Monitoring Internet Service (TEMIS) EUV and UVI under cloud-free conditions are 1.8 times and 1.5 times, respectively, higher than the all-sky measurements by the Brewer. The trend analysis in fractional deviation of monthly UV from the reference value shows a decrease of -0.83% and -0.90% $decade^{-1}$ in the EUV and TUV, respectively, whereas the TR trend is near zero (+0.11% $decade^{-1}$). The trend is statistically significant except for TR trend (p = 0.279). It is possible that the recent UV decrease is mainly associated with increase in total ozone, but the trend in TR can be attributed to the other parameters such as clouds except the ozone. Certainly, the cloud effects suggest that the reason for the differences between UV and TR trends can be explained. In order to estimate cloud effects, the EUV, TUV and TR irradiances have been also evaluated for clear skies (cloud cover < 25%) and cloudy skies (cloud cover ${\geq}$ 75%). Annual mean values show that EUV, TUV and TR are $2.15kJm^{-2}$, $0.83MJm^{-2}$, and $17.9MJm^{-2}$ for clear skies, and $1.24kJm^{-2}$, $0.46MJm^{-2}$, and $7.2MJm^{-2}$ for cloudy skies, respectively. As results, the transmission of radiation through clouds under cloudy-sky conditions is observed to be 58%, 55% and 40% for EUV, TUV and TR, respectively. Consequently, it is clear that the cloud effects on EUV and TUV are 18% and 15%, respectively lower than the effects on TR under cloudy-sky conditions. Clouds under all-sky conditions (average of cloud cover is 5 tenths) reduced the EUV and TUV to about 25% of the clear-sky (cloud cover < 25%) values, whereas for TR, this was 31%. As a result, it is noted that the UV radiation is attenuated less than TR by clouds under all weather conditions.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Review of the study on the surfactant-induced foliar uptake of pesticide (계면활성제에 의해 유도되는 농약의 엽면 침투성 연구 현황)

  • Yu, Ju-Hyun;Cho, Kwang-Yun;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.6 no.1
    • /
    • pp.16-24
    • /
    • 2002
  • Research trends in the measurement of foliar uptake of pesticides and the recently proposed action mechanism of the surfactant-induced uptake of pesticides were reviewed with the related reports and studies. Major techniques used in those fields are bioassay, radiotracer techniques with leaves or cuticular membrane. Recently, a new method using Congo Red as a tracer was proposed. The limiting factor in the pesticides uptake into leaves is the waxy layer which consists of the epicuticular and cuticular wax. Physico-chemical parameters such as molar volume, water solubility and partition coefficient of pesticides have limited influences on the pesticide uptake into leaves. Polydisperse ethoxylated fatty alcohol surfactants are well known as the good activator for many pesticides. It is now generally agreed that uptake activation is not related to the intrinsic surface active properties of surfactants such as surface activity, solvent property, humectancy and critical micelle concentration. Recent studies using ESR-spectroscopy revealed that the surfactants have an unspecific plasticising effect on the molecular structure of the wax and cuticular matrix, leading to increased mobilities of pesticides. Penetration of surfactants into waxy layer altered the pesticide mobility in wax and the partition coefficient of pesticide, and then the pesticides penetration into leaves was enhanced temporally. The enhancing effect of surfactant could be significantly different depending on the carbon number of aliphatic moiety and the number of ethoxy group in polyoxyethylene chain of surfactants. It is suggested that the rate of penetration of surfactants should have a significant relationship with the rate of penetration of pesticides.

Dealumination of $NH_4Y$-Zeolite to Convert to the Hydrophobic Zeolite by High-Temperature Steam Treatment (소수성 제올라이트로의 변환을 위한 고온 수증기처리에 의한 $NH_4Y$-제올라이트의 탈알루미늄)

  • Kim, Jin-Young;Jeon, Dong-Hwan;Chung, Byung-Hwan;Mo, Se-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.420-430
    • /
    • 2005
  • This study was performed to change the hydrophilic $NH_4Y$-zeolite to the hydrophobic one for removal of VOCs by removing the $Al^{3+}$ in the zeolite-structure to increase the Si/Al ratio, for which the three pelleted $NH_4Y$-zeolite samples were contacted separately with the steam of $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$, respectively, in a stainless steel column for 4 hours. Then extraction of the ex-structure aluminum of the hydrolyzed zeolites with the nitric acids of 0.25, 0.50, 0.75, and 0.10 M at $90^{\circ}C$ in 500 mL-flasks, respectively, according to steam temperature were followed. XRD analysises of the dealuminated zeolites showed that the peaks of the zeolites that had been hydrolyzed with the steams of both $500^{\circ}C$ and $600^{\circ}C$ are distorted more with the increase of the concentration of nitric acid used for extraction of the ex-structure aluminums, however, those hydrolyzed with steam of $400^{\circ}C$ became amorphous phase when treated with the all nitric acids of four concentrations. Also the EDX analysises showed that the BET surface areas and TPVS of the zeolites that had been hydrolyzed with the steam of $600^{\circ}C$ were increased with the concentration of the nitric acid when the nitric acids of 0.25 M and 0.5 M had been used but decreased when the nitric acids of 0.75 M and 1.0 M had been used. These results led to the conclusion that both the $600^{\circ}C$ and $500^{\circ}C$-steam and the 0.5 M-nitric acid are appropriate to change the hydrophilic $NH_4Y$-zeolites to the hydrophobic one, which were proven by the measurement of the benzene and tolune-adsorbing capacities showing the same trend as the BET surface area and TPV The Si/Al ratios and water-adsorbing capacities of the dealuminated zeolites were increased and decreased, respectively, with the concentration of the nitric acids so that it showed that the hydrophobicity is increased.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.