• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.024 seconds

The Development of High Efficiency Tempering System using Microwave (마이크로파를 이용한 고 효율 해동 시스템 개발)

  • Cho, Kook-Hee;Park, Seung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.69-74
    • /
    • 2009
  • The tempering system which is developed by this research which sees energy curtailment and from the environmental side which is essential for in hazard analysis critical control point. The tempering system with development experimented frozen pork and fish. As test result, frozen pork region was not thawed occurred plentifully. Like this the actual condition, the case of frozen fish is grind and the bulk and density uniformly was formed, the pork the density was dense and was thought with the fact that the temperature difference change is big. Also after tempering from measurement location center the temperature appeared substitutionally with the low-end thing. This central part of the frozene region is thought the impedance change appears few. To hereafter respects an impedance change is thought that has the necessity which will change the structure of tempering system.

Air Surveillance Using Mode-S Multilateration (모드-S 다변측정법을 이용한 항공감시기술 분석 및 전망)

  • Kim, Chang-Hwan;Han, Jae-Hyun;Kang, Ja-Young
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.3
    • /
    • pp.9-20
    • /
    • 2010
  • Surveillance is an enabler of safety with respect to aircraft separation and as a consequence capacity and efficiency with respect to aircraft operations. The new emerging technology among modern civil aviation surveillance is Multilateration (MLAT) which would affect on the surveillance capacity with both side of surveillance signal and operational properties. Multilateration system is needed to receive the signal which must reach at least 3 ground receivers simultaneously and has the effect that will have on with the ultimate accuracy. In this paper, the principle and the system configuration are reviewed. And its benefit of development is considered with use in situations where it is difficult to locate tranditional radar. This MLAT requires no additional avionics equipment to supply service with more accurate and less expensive. And it is able to enhance performance that meets international standards and extend the investment of air navigation service providers with reducing environmental impact by utilizing a small footprint on existing structures. Finally, it can be added to meet a wide range of coverage requirements and future surveillance needs.

Calculation of Generation Power Integrating Sihwa Tidal Power into Power Systems (시화조력발전 계통연계에 따른 시간대별 발전량 산정)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.157-163
    • /
    • 2007
  • This paper presents a method to calculate generation power for integrating Sihwa tidal power into power systems. The sea levels of 1 minute interval using cubic interpolation based on the forecasted levels of high and low water offered from Nori(National Oceanographic Research Institute) are calculated. If the sea level is greater than the lake level and the difference between sea level and lake level at high tide is over the default value, it begins to calculate the tidal power. It is seen that tidal power can supply power to demand side stably and economically from assessment of effect for integrating tidal power into power systems.

An Implementation of a Current Controlled Inverter for Improved quality of the Grid (계통의 품질개선을 위한 전류제어형 인버터의 구현)

  • Lee S. S.;Jeon C. H.;Ko S. S.;Shin Y. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.515-518
    • /
    • 2004
  • Increasing of the nonlinear power electronics equipments, power conditioning systems have been researched and developed for many years to compensate the harmonic disturbances and the reactive power. The main function of power conditioning systems is to reduce harmonic distortions, since extensive surveys quantify the problems associated with electric networks having non-linear loads. The main function of power conditioner compensates the current instead of the voltage. Therefore the inverter used in power conditioner is mostly the current controlled type. In this paper, we propose the power conditioner using photovoltaic system, which is operated by the PRT(Polarized Ramp Time) current control algorithm. The proposed system could also achieve Demand Side Management's function and Uninterruptible Power Supply's function simultaneously. To verify the proposed current controlled inverter for improved quality of the grid, the detail simulation and experiment results indicate that operation PCS, DSM and UPS can be achieved.

  • PDF

Cascaded Multi-Level Inverter Based IPT Systems for High Power Applications

  • Li, Yong;Mai, Ruikun;Yang, Mingkai;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1508-1516
    • /
    • 2015
  • A single phase H-bridge inverter is employed in conventional Inductive Power Transfer (IPT) systems as the primary side power supply. These systems may not be suitable for some high power applications, due to the constraints of the power electronic devices and the cost. A high-frequency cascaded multi-level inverter employed in IPT systems, which is suitable for high power applications, is presented in this paper. The Phase Shift Pulse Width Modulation (PS-PWM) method is proposed to realize power regulation and selective harmonic elimination. Explicit solutions against phase shift angle and pulse width are given according to the constraints of the selective harmonic elimination equation and the required voltage to avoid solving non-linear transcendental equations. The validity of the proposed control approach is verified by the experimental results obtained with a 2kW prototype system. This approach is expected to be useful for high power IPT applications, and the output power of each H-bridge unit is identical by the proposed approach.

Application of FMECA with Stochastic Approach to Reliability-Centered Maintenance of Electric Power Plants in Korean Power Systems (RCM 수립을 위해 발전설비의 고장확률을 고려한 확률론적 FMECA 평가 기법)

  • Joo, Jae-Myung;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.196-197
    • /
    • 2006
  • Preventive maintenance can avail the generation utilities to reduce cost and gain more profit in a competitive supply-side power market. So, it is necessary to perform reliability analysis on the systems in which reliability is essential. In this paper, RCM (Reliability -Centered Maintenance) analytical method is adopted using real historical failure data in Korean power plants. Therefore, the reliability -based Probability model for predicting the failures of components in the power plant is also established, and application to FMECA(Failure Mode Effects and Critical Analysis) consideration of failure probability, Based on the weighting ranking of generating equipments which status to be probability estimation by FMECA. The FMECA is an engineering analysis and a core activity performed by reliability engineers to review the effects of probable failure modes of generating equipments and assemblies of the power system on system performance. The results of this paper show that application of FMECA with stochastic approach to the preventive maintenance can efficiently avail decreasing the cost on maintenance and hence improve the total benefit.

  • PDF

Component Replacement Ordering Evaluation for Proper Reliability Maintenance in Power Distribution System (배전계통 적정 신뢰도 유지를 위한 설비교체 순위 평가)

  • Lee, Hee-Tae;Kim, Jae-Chul;Moon, Jong-Fil;Chu, Cheol-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.48-50
    • /
    • 2005
  • New environment change of electric power system focused in consumer's energy supply and demand. But electric power reliability preservation and reliability improvement countermeasure also need for long-term. It is need that change equipments that is composing electric power system in well-timed time and by maintaining, prevent breakdown beforehand and prevent consumer's power interruption by equipment fail. However, as only quantitative estimation is available by reliability estimation method that is presented in existing, it is no to use in dictionary fault prevention. Therefore, applied optimum reliability preservation through existent equipment fault data analysis of electric power system in equipment replace side, and this when maintain equipment replace of electric power system for reliability preservation using responsiveness analysis to base ordering evaluate. In existing about main equipment plain that this paper is power system the valued failure rate use this by score and precedence of electric power system equipment for replace of system considered expense.

  • PDF

The Development of Biplots System (행렬도 시스템(BIPLOTS SYSTEM)의 개발)

  • 최용석;현기홍
    • The Korean Journal of Applied Statistics
    • /
    • v.13 no.2
    • /
    • pp.297-306
    • /
    • 2000
  • Many users have made the most often use of the SAS system in statistical data analysis all over the world. But it is difficult to use the grand procedures and language of the SAS system. Therefore the side of program development has changed in the graphic-oriented and menu-centered way like SASj ASSIST, SASjINSICHT after a version 6.08 turned into the Window environment. A biplots is a multivariate data analysis technique that graphically describes both relationships among the multidimensional observations and relationships among the variables. But there were not the procedure and graphic interface for a biplots algorithm in the SAS system. In this paper, there are two objects. First, we supply users with the convenience of the environment of CLI, which is constructed with SASj AF and SCL, to solve the problem that we have programed a biplots algorithm with the SASjIML one by one. Second, we reflect the current of the Information Age which means the spread of various kinds of system construction to extract useful information from data with the help of the development of hardware and software.

  • PDF

The Impact of Gate Leakage Current on PLL in 65 nm Technology: Analysis and Optimization

  • Li, Jing;Ning, Ning;Du, Ling;Yu, Qi;Liu, Yang
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.99-106
    • /
    • 2012
  • For CMOS technology of 65 nm and beyond, the gate leakage current can not be negligible anymore. In this paper, the impact of the gate leakage current in ring voltage-controlled oscillator (VCO) on phase-locked loop (PLL) is analyzed and modeled. A voltage -to-voltage (V-to-V) circuit is proposed to reduce the voltage ripple on $V_{ctrl}$ induced by the gate leakage current. The side effects induced by the V-to-V circuit are described and optimized either. The PLL design is based on a standard 65 nm CMOS technology with a 1.8 V power supply. Simulation results show that 97 % ripple voltage is smoothed at 216 MHz output frequency. The RMS and peak-to-peak jitter are 3 ps and 14.8 ps, respectively.

Coordinated Control of Reactive Power between STATCOMs and Wind Farms for PCC Voltage Regulation

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Van, Tan Luong;Kang, Jong-Ho
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.909-918
    • /
    • 2013
  • This paper proposes a coordinated control of the reactive power between the STATCOMs (static synchronous compensators) and the grid-side converters (GSC) of wind farms equipped with PMSGs (permanent-magnet synchronous generators), by which the voltage fluctuations at the PCC (point of common coupling) are mitigated in the steady state. In addition, the level of voltage sags is reduced during grid faults. To do this, the GSC and the STATCOM supply reactive power to the grid coordinately, where the GSCs are fully utilized to provide the reactive power for the grid prior to the STATCOM operation. For this, the GSC capability of delivering active and reactive power under variable wind speed conditions is analyzed in detail. In addition, the PCC voltage regulation of the power systems integrated with large wind farms are analyzed for short-term and long-term operations. With this coordinated control scheme, the low power capacity of STATCOMs can be used to achieve the low-voltage ride-through (LVRT) capability of the wind farms during grid faults. The effectiveness of the proposed strategy has been verified by PSCAD/EMTDC simulation results.