• Title/Summary/Keyword: Structural safety test

Search Result 941, Processing Time 0.026 seconds

A Study on the Development of Prototype for Green Roof System in Korea (한국형 Green Roof System 개발을 위한 Proyotype 제안)

  • Kim, Hyen-Soo
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.3-11
    • /
    • 2003
  • The purpose of this study is to develope an available outdoor insulation construction for the green roof system in Korea. On its own economical and structural problems of constructional risk, the typical outdoor insulation construction on the korean spot does not function efficiently with the green roof. Therefore, this study consists of four main contents as follows: 1. The objectives of the study are established by analysing the problems of the typical in- and outdoor roof insulation system in korea. 2. The foreign outdoor insulation systems for the green roof are clarified to find out an acceptable prototype for Korea. 3. According to loadtest, the prototype, which has a waterproof on the thermal insulation, is tested to demonstrate the structural safety. 4. The U-value test of the prototype on KS F 2277 brings the thermal performance of the green roof system, which can influence the thickness of the insulation.

Research on the mechanical properties of membrane connections in tensioned membrane structures

  • Zhang, Yingying;Zhang, Qilin;Li, Yang;Chen, Lu
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.745-762
    • /
    • 2014
  • As an important part, the connections generally are important for the overall behavior of the structure and the strength and serviceability of the connection should be ensured. This paper presents the mechanical properties of membrane connections in tensioned membrane structure. First, the details of common connections used in the membrane structure are introduced. Then, the common connections including membrane seam, membrane-flexible edge connection and membrane-rigid edge connection are tested and the corresponding failure mechanisms are discussed. Finally, the effects of connection parameters on the connection strength are investigated and proper connection parameters are proposed. The strength reduction factors corresponding to different connection types are proposed, which can be references for the design and analysis of membrane structures.

Design Optimization of Nuclear Power Plant Structures with High-Strength Reinforcements (원전구조물의 고강도철근 설계 최적화 방안)

  • Lee, Byung Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.137-138
    • /
    • 2017
  • Generally, a lot of reinforcements are used in nuclear power plant concrete structures in order to improve the structural safety, but it may cause several potential problems due to the overcrowded reinforcement, such as the degradation of concrete quality, the construction delay and the increase of construction cost. In order to resolve these problems, structural test researches and code change studies on using high-strength reinforcement (Gr.80) in unclear power plant structures are under way, and there is good progress in code change of ASM BPVC.III.2 and ACI 349. This purpose of this study is to review the code change status ASM BPVC.III.2, ACI 349 under way to use the high-strength reinforcement in nuclear power plant structures. Also I will introduce the design optimization of NPP structures with high-strength reinforcements in order to maximize the effect and minimize the problem when using the high-strength reinforcements in NPP structures.

  • PDF

Some aspects of the analyses of glass structures exposed to impact load

  • Grozdanic, Gabrijela;Galic, Mirela;Marovic, Pavao
    • Coupled systems mechanics
    • /
    • v.10 no.6
    • /
    • pp.475-490
    • /
    • 2021
  • With glass becoming a structural material there is a whole new approach for loading and ensuring the safety of construction. Due to its brittle nature, it is necessary to predict all possible problems so that structural integrity would not be endangered. In this paper, different approaches to modelling the glass elements are presented with references to the advantages, disadvantages, and application of each of them. The intention is clear, there is a need to improve and simplify the design guidelines. Given the increasing use of glass in construction it is not practical to produce experimental tests each time when the verification is needed. Today, architecture is bringing us different types of structures and every project presents a new challenge for engineers. A practical and simple approach is crucial for progress and efficiency. In this paper, different approaches to modelling glass are presented with an emphasis on soft body impact.

Thermal buckling analysis of metal-ceramic functionally graded plates by natural element method

  • J.R., Cho
    • Structural Engineering and Mechanics
    • /
    • v.84 no.6
    • /
    • pp.723-731
    • /
    • 2022
  • Functionally graded materials (FGMs) have been spotlighted as an advanced composite material, accordingly the intensive studies have focused on FGMs to examine their mechanical behaviors. Among them is thermal buckling which has been a challenging subject, because its behavior is connected directly to the safety of structural system. In this context, this paper presents the numerical analysis of thermal buckling of metal-ceramic functionally graded (FG) plates. For an accurate and effective buckling analysis, a new numerical method is developed by making use of (1,1,0) hierarchical model and 2-D natural element method (NEM). Based on 3-D elasticity theory, the displacement field is expressed by a product of 1-D assumed thickness monomials and 2-D in-plane functions which are approximated by NEM. The numerical method is compared with the reference solutions through the benchmark test, from which its numerical accuracy has been verified. Using the developed numerical method, the critical buckling temperatures of metal-ceramic FG plates are parametrically investigated with respect to the major design parameters.

Crack growth prediction on a concrete structure using deep ConvLSTM

  • Man-Sung Kang;Yun-Kyu An
    • Smart Structures and Systems
    • /
    • v.33 no.4
    • /
    • pp.301-311
    • /
    • 2024
  • This paper proposes a deep convolutional long short-term memory (ConvLSTM)-based crack growth prediction technique for predictive maintenance of structures. Since cracks are one of the critical damage types in a structure, their regular inspection has been mandatory for structural safety and serviceability. To effectively establish the structural maintenance plan using the inspection results, crack propagation or growth prediction is essential. However, conventional crack prediction techniques based on mathematical models are not typically suitable for tracking complex nonlinear crack propagation mechanism on civil structures under harsh environmental conditions. To address the technical issue, a field data-driven crack growth prediction technique using ConvLSTM is newly proposed in this study. The proposed technique consists of the four steps: (1) time-series crack image acquisition, (2) target image stabilization, (3) deep learning-based crack detection and quantification and (4) crack growth prediction. The performance of the proposed technique is experimentally validated using a concrete mock-up specimen by applying step-wise bending loads to generate crack growth. The validation test results reveal the prediction accuracy of 94% on average compared with the ground truth obtained by field measurement.

The Optimal Design Technique for Improving Durability of Spline Shaft of the Self Propelled Artillery' Generator (자주포 발전기 스플라인 축 내구성 향상을 위한 최적 설계 기법)

  • Kim, Byeong Ho;Kang, Hyen Jae;Park, Young Il;Seo, Jae Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.485-491
    • /
    • 2015
  • In this study, the experimental and analytical investigation on structural integrity evaluation of spline shaft of self propelled artillery' generator were carried out. For this work, macro and microstructure fractography of spline shaft were observed. According to the results of the structure analysis and simulation, the shaft was redesigned and optimized. To improve the stiffness and shear stress, the material was changed from the SNCM220 to SNCM439 and surface roughness and protective coating treatment are changed to increase the stress relaxation, respectively. From the result of the torsion test of shaft and accelerated life test of generator, the shaft of a SNCM439 with heat-treatment(Q/T) and electroless nickel plating was superior quality reliability and durability than the others. Therefore, modeling and simulation corresponded well with the experimental result and structural safety was confirmed by generator performing.

Accuracy Enhancement of Reflection Signals in Impact Echo Test

  • Lho, Byeong-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.924-929
    • /
    • 2003
  • A majority of infrastructures has been deteriorated over time. Therefore, it is very important to verify the quality of construction, and the level of structural deterioration in existing structures, to ensure their safety and functionality. Many researchers have studied non-destructive testing (NDT) methods to identify structural problems in existing structures. The impact echo technique is one of the widely used NDT techniques. The impact echo technique has several inherent problems, including the difficulties in P-wave velocity evaluation due to inhomogeneous concrete properties, deterioration of evaluation accuracy where multiple reflection boundaries exist, and the influence of the receiver location in evaluating the thickness of the tested structures. Therefore, the objective of this paper is to propose an enhanced impact echo technique that can reduce the aforementioned problems and develop a Virtual Instrument for the application via a thickness evaluation technique which has same technical background to find deterioration in concrete structures. In the proposed impact echo technique, transfer function from dual channel system analysis is used, and coherence is improved to achieve reliable data. Also an averaged signal -ensemble- is used to achieve more reliable results. From the analysis of transfer function, the thickness is effectively identified.

An Evaluation of Fire Resistance and Mock-up Test of the Alumino-silicate Fire Resistant Board (알루미노 실리케이트계 내화보드의 내화성능 및 현장적용성 평가)

  • Kim, Doo-Ho;Park, Dong-Cheol;Kim, Woo-Jae;Lee, Sea-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.43-47
    • /
    • 2010
  • The use of high-strength concrete has increased for its excellent structural stability as buildings become higher and bigger than ever before in Korea and overseas recently. The functional requirement of building materials has also been bolstered so for the high -performance, high-quality construction materials to be used more extensively. However, the internal structure of the high-strength concrete is very dense so spalling can be caused during fire. The spalling in turn can cause critical structural damages followed by the fatal consequences, demolition of the building. Therefore, ensuring fire safety for high-rise buildings is assumed to be urgent. Alumino-silicate fire resistant board producing technology has been developed in situations that new materials with excellent fire resistance and easy installation has been sought. The alumino-silicate fire resistant board turned out to exhibit not only fire resistance and excellent physical and dynamical characteristics but also excellent onsite applicability and easy process and transportation after completing Mock-up test. Its excellence as a high-performance building materials was proven.

  • PDF

An Performance Evaluation of Post-installed Anchor according to the Effective Embedment Length (유효묻힘깊이에 따른 후설치앵커의 인발성능평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;An, Yeong Seung;Hur, Moo-Won
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.4
    • /
    • pp.19-25
    • /
    • 2019
  • Concrete wedge anchor is one of structural components to transfer load of an object attached to a primary structure. Recently, as retrofitting concrete structure is becoming a main issue, mechanical capacity of the anchor should be secured enough. In spite of the structural safety of Cast-in-place anchor, Post-installed anchor is more widely used with ease of placement or change of construction method. However, the post-installed anchors domestically produced have excessive coefficient of variation over 15% of ultimate tensile strength, which yields deteriorated quality in tensile strength. In this research, tensile strength test of anchors, which have improved sleeve and header and produced by a domestic company, was conducted for two variables, concrete strength and effective embedment depth. As a result, enough coefficients of variations were secured in all specimens. Also, in comparison to foreign products, the domestic ones have equal or higher performance.