• 제목/요약/키워드: Stress reduction ratio

검색결과 285건 처리시간 0.029초

Study on push-out test and bond stress-slip relationship of circular concrete filled steel tube

  • Yin, Xiaowei;Lu, Xilin
    • Steel and Composite Structures
    • /
    • 제10권4호
    • /
    • pp.317-329
    • /
    • 2010
  • According to the results of 9 circular concrete filled steel tube (CFT) push-out tests, a new theoretical model for average bond stress versus free end slip curve is proposed. The relationship between verage bond stress and free end slip is obtained considering some varying influential parameters such as slenderness ratio and diameter-to-thickness ratio. Based on measured steel tube strain and relative slip at different longitudinal positions, the distribution of bond stress and relative slip along the length of steel tube is obtained. An equation for predicting the varying bond-slip relationship along longitudinal length and a position function reflecting the variation are proposed. The presented method can be used in the application of finite element method to analyze the behavior of CFT structures.

사각 평판에서 타원의 형상 변화에 따른 응력집중계수에 관한 연구 (A Study on the Stress Concentration Coefficient due to the Change of Ellipse on a Square Plate)

  • 박정호;김형준;박기훈;조우석;제승봉;김현수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1434-1437
    • /
    • 2003
  • Sometimes open holes are required for the function and the weight reduction of structure and machinery. However, the serious stress concentration occurs because of the geometric discontinuity caused by the holes and cutting section. In this study, it is attempted to obtain the stress concentration coefficients of the inner surface of the hole boundary by changing the position and the shape of holes on the homogeneous isotropic plate. And the effects on the plate are investigated. The results show that the stress level becomes low and the distribution area widens the position of stress concentration changes as the ratio a/b increases and change to a circle. And as the ratio a/l decreases, the stress concentration reduces. As the plate with three holes. the stress $\sigma$$\_$x/ and $\tau$$\_$xy/ of hole 1,3 becomes high, especially $\sigma$$\_$x/ dominant and high.

  • PDF

사각 평판에서 타원의 위치와 형상 변화에 따른 응력집중계수의 변화에 관한 연구 (A Study on the Stress Concentration Coefficient due to the Change of Position and Shape of Ellipse on a Square Plate)

  • 최경호;권영석;박기훈;김현수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.833-836
    • /
    • 2002
  • Sometimes open holes are required for the function and the weight reduction of structure and machinery. However, the serious stress concentration occurs because of the geometric discontinuity caused by the holes and cutting section. In this study, it is attempted to obtain the stress concentration coefficients of the inner surface of the hole boundary by changing the position and the shape of holes on the homogeneous isotropic plate. And the effects on the plate are investigated. The results show that the stress level becomes low and the distribution area widens the position of stress concentration changes as the ratio ah increases and change to a circle. And as the ratio a/l decreases, the stress concentration reduces.

  • PDF

The influence of screw type and osseointegration ratio on stress distribution in two different endosseous implants

  • Han, Jung-Suk
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.348-357
    • /
    • 2000
  • The purpose of this study is to examine the effect of partial osseointegration situation on bone loading patterns around two different free-standing screw shaped implants (Nobel Biocare, Gothenburg, Sweden and Degussa-Huls, Hanau, German). Two dimensional axisymmetric Finite element models of two implants(10mm length and 4mm diameter) were created according to different bone quantity, quality and osseointegration ratio in maxilla and mandible bone. At the same time uni-cortical and hi-cortical fixation were analyzed. Generally, full bond case showed less stress than partial bond case in overall area and mandibular model showed less amount of stress than that of maxilla model. Maximum stress of the Branemark implant is higher than that of ANKYLOS regardless of bonding ratio at crestal and apex region. However, more stress concentration was noted in ANKYLOS implant at screw body area especially in mandible. The effect of bicortical fixation on crestal bone stress reduction is dramatical in mandible however, there was no significant effect in maxillary case. The effect of partial bond on stress distribution was more significant at screw body and apex region than in crestal region. Partial bond cases demonstrated greater stress accumulation in trabecular bone than cortical bone. It is concluded that the more accurate model of implant and bone which affects stress and strain distribution is needed to mimic in vivo behavior of implants.

  • PDF

알루미늄 합금(AI7050-T7451)의 반복 굽힘 하중하의 프레팅 피로거동 평가 (Evaluation of Fretting Fatigue Behavior of Aluminum Alloy(A17050-T7451) Under Cyclic Bending Load)

  • 김종성;윤명진;최성종;조현덕
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.25-34
    • /
    • 2010
  • Fretting damage reduces fatigue life of the material due to low amplitude cyclic sliding and changes in the contact surfaces of strongly connected machine and structures such as bolt, key, fixed rivet and connected shaft, which have relative slip of repeatedly very low frequency amplitude. In this study, the fretting fatigue behavior of 7050-T7451 aluminum alloys used mainly in aircraft and automobile industry were evaluated. The plain fatigue test and fretting fatigue test under cyclic bending load carried out commercial bending fatigue tester and specially devised equipments to cause fretting damage. From these experimental work, the following results obtained: (1) The plain fatigue limit for stress ratio R=-l was about 151MPa. (2) In case of fretting fatigue, fatigue limit for stress ratio R=-l about 72MPa, the fatigue limit for R=0 about 81MPa, and the fatigue limit for R=0.3 about 93MPa. (3) The fatigue limit reduction rates by the fretting damage were about 52%(R=-1), 46%(R=0) and 38%(R=0.3) respectively. (4) The fatigue limit reduction rate decreased with stress ratio increase. In fretting bending test, as stress ratio increased, occurrence of initial oblique crack by fretting decreased or phased out, so that fracture surfaces were formed by plain fatigue crack occurrence, and such tendency was notable as stress amplitude increased. (5) Tire tracks and rubbed scars were observed in the fracture surface and contacted surface.

Influence of Hold Time and Stress Ratio on Cyclic Creep Properties Under Controlled Tension Loading Cycles of Grade 91 Steel

  • Kim, Woo-Gon;Park, Jae-Young;Ekaputra, I Made Wicaksana;Kim, Seon-Jin;Jang, Jinsung
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.581-591
    • /
    • 2017
  • Influences of hold time and stress ratio on cyclic creep properties of Grade 91 steel were systemically investigated using a wide range of cyclic creep tests, which were performed with hold times (HTs) of 1 minute, 3 minutes, 5 minutes, 10 minutes, 20 minutes, and 30 minutes and stress ratios (R) of 0.5, 0.8, 0.85, 0.90, and 0.95 under tension loading cycles at $600^{\circ}C$. Under the influence of HT, the rupture time increased to HT = 5 minutes at R = 0.90 and R = 0.95, but there was no influence at R = 0.50, 0.80, and 0.85. The creep rate was constant regardless of an increase in the HT, except for the case of HT = 5 minutes at R = 0.90 and R = 0.95. Under the influence of stress ratio, the rupture time increased with an increase in the stress ratio, but the creep rate decreased. The cyclic creep led to a reduction in the rupture time and an acceleration in the creep rate compared with the case of monotonic creep. Cyclic creep was found to depend dominantly on the stress ratio rather than on the HT. Fracture surfaces displayed transgranular fractures resulting from microvoid coalescence, and the amount of microvoids increased with an increase in the stress ratio. Enhanced coarsening of the precipitates in the cyclic creep test specimens was found under all conditions.

경사기능재료 판의 최적설계 (Optimal Design of Functionally Graded Plates)

  • 나경수;김지환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1061-1064
    • /
    • 2006
  • Optimal design of functionally graded plates is investigated considering stress and critical temperature. Material properties are assumed to be temperature dependent and varied continuously in the thickness direction. The effective material properties are obtained by applying linear rule of mixtures. The 3-D finite element model is adopted using an 18-node solid element to analyze more accurately the variation of material properties and temperature field in the thickness direction. For stress analysis, the tensile stress ratio and compressive stress ratio of the structure under mechanical load are investigated. In the thermo-mechanical buckling analysis, temperature at each node is obtained by solving the steady-state heat transfer problem and Newton-Raphson method is used for material nonlinear analysis. Finally, the optimal design of FGM plates is studied for stress reduction and improving thermo-mechanical buckling behavior, simultaneously.

  • PDF

일정변형률(CRS) 시험에서의 압밀특성 (Consolidation Characteristics at the Constant Rate of Strain(CRS) Test)

  • 이달원;김시중
    • 농업과학연구
    • /
    • 제37권3호
    • /
    • pp.491-499
    • /
    • 2010
  • This study was carried out to investigate the consolidation characteristics of the remolded clay by the oedometer and the constant rate of strain(CRS) consolidation tests. As the rate of strain increases, the settlement rapidly decreased. As the ratio of the sand in the specimen increases, its effect on the rate of strain to the settlement was reduced. As the effective stress increased, the void ratio decreased, while the rate of strain increased, it did not show a clear variation. The reduction of the void ratio was shown to be less than the oedometer test. The coefficient of vertical consolidation with effective stress showed very large variation around preconsolidation stress, but the rate of strain did not provide significant effects. The rate of strain with effective stress gradually decreased at all tests and mixed ratio of sand. The rate of strain at the constant rate of strain tests showed smaller than in the oedometer test. The coefficient of consolidation at the constant rate of strain tests showed much more increase than in the oedometer test. The ratio of the vertical coefficient of consolidation by the odometer and the constant rate of strain tests showed a large difference according to various tests method and mixing ratio. Therefore, it is recommended that careful attention should be paid to designing the soft ground improvement.

Physiological Response to Salinity Stress of Japonica/Indica Lines Tolerant to Salt at Seedling Stage

  • Ko, Jong-Cheol;Lee, Kyu-Seong;Kim, Ki-Young;Choi, Weon-Young;Kim, Bo-Kyung;Shin, Woon-Cheol;Ko, Jae-Kwon;Yum, Song-Joong
    • 한국육종학회지
    • /
    • 제43권5호
    • /
    • pp.391-398
    • /
    • 2011
  • Physiological responses to salinity stress were evaluated in six rice genotypes differing in their tolerance to salinity at the seedling stage. Susceptible genotypes ('Dongjingbyeo', 'Hwayeongbyeo', and 'IR29') showed salt injury symptoms (mean 8.8) and higher visual score under salt stress than that of tolerant ones ('Pokkali', 'IR74009', and 'IR73571'). As salinity affects growth and physiological parameters, the six genotypes thus showed significant reduction because of salt stress. Tolerant Japonica/Indica bred lines ('IR74009', 'IR73571') showed lower reduction, 33.9%, 34.5%, and 50%, respectively, in plant seedling height, dry shoot weight and dry root weight than those of the susceptible Japonica varieties ('Dongjingbyeo', 'Hwayeongbyeo'), and the highest reduction under salt stress was observed in dry root weight, followed by dry shoot weight and seedling height, respectively. Shoot $Na^+$ concentration of IR74099 and IR73571 was lower than that of the susceptible varieties, 'Dongjinbyeo' and 'Hwayeongbyeo'. There were no significant differences among genotypes in root $Na^+$ concentration. Shoot $K^+$ concentration showed a reverse tendency compared to shoot $Na^+$ concentration. IR74009 and IR73571 had considerably lower ratio compared to 'Dongjinbyeo' and 'Hwayeongbyeo' in $Na^+/K^+$ ratio of their shoot and was not different the tolerant check, 'Pokkali'.

Biaxial creep property of ethylene tetrafluoroethylene (ETFE) foil

  • Li, Yintang;Wu, Minger
    • Structural Engineering and Mechanics
    • /
    • 제54권5호
    • /
    • pp.973-986
    • /
    • 2015
  • Ethylene tetrafluoroethylene (ETFE) foil is a novel structural material which has being used in shell and spatial structures. This paper studies biaxial creep property of ETFE foil by creep tests and numerical simulation. Biaxial creep tests of cruciform specimens were performed using three stress ratios, 1:1, 2:1 and 1:2, which showed that creep coefficients in biaxial tension were much smaller than those in uniaxial one. Then, a reduction factor was introduced to take account of this biaxial effect, and relation between the reduction factor and stress ratio was established. Circular bubble creep test and triangle cushion creep test of ETFE foil were performed to verify the relation. Interpolation was adopted to consider creep stress and reduction factor was involved to take account of biaxial effect in numerical simulation. Simulation results of the bubble creep test embraced a good agreement with those measuring ones. In triangle cushion creep test, creep displacements from numerical simulation showed a good agreement with those from creep test at the center and lower foil measuring points.