• 제목/요약/키워드: Story height

검색결과 198건 처리시간 0.021초

시가지내 산악경관의 시점 높이별 조망 특성 - 청주시 우암산을 대상으로 - (The View Character of Mountainscape of a City according to Visual Point Level - In a Case of Mt. Uam -)

  • 정정섭;권상준;조태동
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.497-503
    • /
    • 2004
  • In this research, we have performed a T-test to see how the relationship between dependent variable or visual point level and independent variable or visual quantity is in order to clear up the correlation between pattern of visual point and visual quantity by the constituents of a view from a different visual point level and the results are as follows: 1) In case of the character of Mt. Uam landscape of the city, Uamsan is set as a fixed point and about a direction of view(D), the north is a datum point from which the range of direction is distributed within 1800 westwardly and the visual range(R) is also within 2000m. An elevation is an average of 7.40 and the average story of the buildings is 3.85. Here the height of a story is about 4m so the average of the visual point difference is estimated at 15.4m. 2) The type of visual point is divided into the intersection group and the front of the highly used public buildings group. Double intersection types account for about 78.80%(52 spots) which forms a majority part of LCP. 3) The analysis of the difference of visual point level divided by eye level and that of the top of the buildings has been proved that there's a sharp difference resulted from t-test at 1 % significant level. The significant difference of elevation from height difference(l5.93m), however, has not been shown. 4) From the result of T-test about visual quantity by the elements of a view from a different visual point level, the visual quantity of mountain(VQM), sky(VQS), ground(VQG) is significant at about 1% each and that of building(VQB) is at about 5%. The difference in visual quantity of a mountain by the visual point level is at about 4% which can meet a marginal level of LCP necessary for evaluation of mountainscape.

최소깊이 프리캐스트 프리스트레스트 U형보의 최적화 (Optimization for Precast Prestressed Wide-U Beams with the Least Depth)

  • 유승룡
    • 콘크리트학회논문집
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2004
  • 지하공사비는 전체공사비를 결정짓는 중요한 요소로서 일반적으로 동일한 층고의 지상공사비의 2${\~}$2.5배에 해당한다. 본 연구에서 지하주차장 층고를 대폭적으로 감소할 수 있는 일방향 슬래브 구조도와 최소깊이 U형보를 제안하였다. 최적설계에 의해 제안된 U형보는 기존의 직사각형 단면보다 보깊이를 최소 12${\~}$34cm 까지 감축이 가능할 것으로 예상된다. 본 연구에서 두 개의 대표적인 실물크기 U형보를 실험하였다. 이 실험에서 U형보는 설계하중과 공칭강도를 상회하는 휨강도에서 최종 파괴되었다. 그러나 토핑콘크리트가 굳기전 단순지지 상태에서 시공 하중에 의한 휨균열이 발생할 가능성이 있는 것으로 판단되었으므로 보중앙에 가설 시공지주를 사용하는 것이 요구된다.

GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가 (An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP)

  • 류재호;박세호;주영규;김상대
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.125-135
    • /
    • 2011
  • 최근 타워형 아파트구조에 많이 사용되고 있는 무량판 구조시스템을 대신해 층고절감 및 장스팬 구현 그리고 내화성능향상을 목적으로 GFRP를 이용한 경량합성바닥을 개발하였다. GFRP를 이용한 경량합성바닥은 웨브에 개구부를 가지는 비대칭 강재보 하부에 GFRP를 부착하고 슬래브에 경량체를 삽입한 중공합성바닥이다. 이에 개발된 합성바닥의 휨성능을 평가하기 위해 GFRP, 중공률, 웨브의 개구부 등을 변수로 실대 실험을 수행하였다. 그 결과 GFRP를 이용한 합성보 실험체는 기준 실험체에 비해 휨내력 및 강성 측면에서 10% 높은 성능을 나타냈으며, 구조물이 항복할 때까지 완전합성거동하였다. 항복 이후 웨브개구부 주변의 응력집중현상에 의해 연성이 감소하는 현상이 나타났으며, 최대내력점까지 미끄러짐의 발생은 미소하였다. 내력설계 측면에서는 안전율을 고려해 해석값의 85%를 설계내력으로 평가하는 것이 타당한 것으로 나타났다.

세미슬림 AU 합성보의 시공 단계 안전성 평가 (Safety Evaluation of Semi-Slim AU Composite Beam During Construction)

  • 김영호;김도범;김대진;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.57-66
    • /
    • 2018
  • Recently various composite beams in which concrete is filled in the U-shaped steel plate have been developed for saving story height and reducing construction period. Due to the high flexural stiffness and strength, they are widely being used for the building with large loads and long spans. The semi-slim AU composite beam has proven to take highly improved stability compared to the existing composite beams, because it consists of the closed steel section by attaching cap-type shear connectors to the upper side of U-shaped steel plate. In this study the finite element analyses were performed to evaluate the safety of the AU composite beam with unconsolidated concrete which were sustained through the closed steel section during the construction phase. The analyses were performed on the two types of cross section applied to the fabrication of AU composite beams, and the results were compared to the those of 2-point bending tests. In addition, the flexural performance according to the space of intermittent cap-type shear connectors and the location of reinforcing steel bars for compression was comparatively investigated. Through the results of analytical studies, it is preferable to adopt the yield moment of AU composite beam for evaluating the safety in the construction phase, and to limit the space of intermittent shear connectors to 400 mm or less for the construction load.

Hurricane vulnerability model for mid/high-rise residential buildings

  • Pita, Gonzalo L.;Pinelli, Jean-Paul;Gurley, Kurt;Weekes, Johann;Cocke, Steve;Hamid, Shahid
    • Wind and Structures
    • /
    • 제23권5호
    • /
    • pp.449-464
    • /
    • 2016
  • Catastrophe models appraise the natural risk of the built-infrastructure simulating the interaction of its exposure and vulnerability with a hazard. Because of unique configurations and reduced number, mid/high-rise buildings present singular challenges to the assessment of their damage vulnerability. This paper presents a novel approach to estimate the vulnerability of mid/high-rise buildings (MHB) which is used in the Florida Public Hurricane Loss Model, a catastrophe model developed for the state of Florida. The MHB vulnerability approach considers the wind pressure hazard exerted over the building's height as well as accompanying rain. The approach assesses separately the damages caused by wind, debris impact, and water intrusion on building models discretized into typical apartment units. Hurricane-induced water intrusion is predicted combining the estimates of impinging rain with breach and pre-existing building defect size estimates. Damage is aggregated apartment-by-apartment and story-by-story, and accounts for vertical water propagation. The approach enables the vulnerability modeling of regular and complex building geometries in the Florida exposure and elsewhere.

스틸하우스 설계 자동화의 필요성과 적용방법에 관한 연구 (Study on the Design Automation of Steel House Shop drawing)

  • 원완연;박현수
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.103-106
    • /
    • 2006
  • This study proposes a method of generating steel house shop drawing in an automated design method, reducing construction manpower and period. With one hour fire-resistant approval code, reflecting work ability and efficiency, steel-framed house market is expected to extend from one or two story house to multi-purpose facilities up to four story height. More models have been constructed in this system than the first appearance of fire-resistant approval in Korea in 1997. Also, cost estimation of components such as frame walls, roof trusses and floors is obtained with shop drawings. Also, the lack of suppliers of steel framed house shop drawing and unstandardized drawing method get constructors have difficulty in understanding its design. In steel framed house industry, shop drawings are essential part in building and constructing framework and they have major effects on construction deadlines and expenses. By exploring method of shop drawing automation, this study aims to optimize work flow with a standardized drawing method. The proposed system can be applied to manufacturing automation in domestic industry of factory-built panelizing method in the near future.

  • PDF

Design aspects for minimizing the rotational behavior of setbacks buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1049-1066
    • /
    • 2016
  • An approximate analysis is presented for multi-story setback buildings subjected to ground motions. Setback buildings with mass and stiffness discontinuities are common in modern architecture and quite often they are asymmetric in plan. The proposed analysis provides basic dynamic data (frequencies and peak values of base resultant forces) and furthermore an overview of the building response during a ground excitation. The method is based on the concept of the equivalent single story system, which has been introduced by the author in earlier papers for assessing the response of uniform in height buildings. As basic quantities of the dynamic response of elastic setback buildings can be derived by analyzing simple systems, a structural layout of minimum elastic rotational response can be easily constructed. The behavior of such structural configurations, which is basically translational into the elastic phase, is also examined into the post elastic phase when the strength assignment of the various bents is based on a planar static analysis under a set of lateral forces simulating an equivalent 'seismic loading'. It is demonstrated that the almost concurrent yielding of all resisting elements preserves the translational response, attained at the end of the elastic phase, to the post elastic one.

Evaluation of ductility and response modification factor in moment-resisting steel frames with CFT columns

  • Hashemi, Seyed Sh.;Sadeghi, Kabir;Vaghefi, Mohammad;Shayan, Kaveh
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.643-652
    • /
    • 2017
  • One of the methods to strengthen the structures against the seismic lateral loading is the employment of the composite columns. A concrete-filled tube (CFT) has the cumulative advantages of steel and concrete. Concrete-filled steel tube columns have been widely used in the moment-resisting frame (MRF) structures, located in both non-seismic zones and high-risk seismic zones. In this paper, the results of studies on two important seismic parameters of ductility and the response modification factor (RMF) of the MRFs with CFT columns are submitted. While the studies are carried out, the effects of span length-story height ratio, the strength of materials and seismic behavior of MRFs are considered. In this regard, the ductility, RMF and the strength of 36 models of the steel MRFs with CFTs are analyzed. The fiber plastic hinges numerical simulation and pushover analysis method are used in the calculations. Based on the obtained results, the RMFs suitable for the 5-, 10- and 15- story frames are proposed.

A lateral load pattern based on energy evaluation for eccentrically braced frames

  • Fakhraddini, Ali;Fadaee, Mohammad Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.623-632
    • /
    • 2018
  • Performance-Based Plastic Design (PBPD) method has been recently developed to evaluate the behavior of structures in different performance levels. The PBPD method utilizes a base shear force and a lateral load pattern that are estimated based on energy and yielding mechanism concepts. Using of current lateral force pattern results in weak structural members in upper stories of a structure so that the values of the story drift in these stories are larger than the target drift, particularly in high-rise buildings. Therefore, such distribution requires modifications to overcome this drawback. This paper proposes a modified lateral load pattern for steel Eccentrically Braced Frames (EBFs) based on parametric study. In order to achieve the modified load pattern, a group of 26 EBFs has been analyzed under a set of 20 earthquake ground motions. Additionally, results of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to derive the new load pattern. To prove the efficiency of present study, three EBFs as examples were designed by modified pattern and current PBPD distribution. Inelastic dynamic analyses results showed that the story drifts using modified lateral load pattern were well within the target values in comparison with current pattern in PBPD, particularly where the effect of the height is significant. The modified load pattern reduces the possibility of underdesigning in upper levels and overdesigning in lower levels of the frames.

Alternatives to Enhance Flat Slab Ductility

  • Husain, Mohamed;Eisa, Ahmed S.;Roshdy, Ramy
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.161-169
    • /
    • 2017
  • Flat slab systems are vastly used in multi-story buildings because of their savings in story height and construction time, as well as for their flexibility in architectural remodeling. However, they frequently suffer brittle punching-shear failure around columns, especially when subjected to lateral loads. Therefore, seismic codes labeled flat slabs as non-ductile systems. This research goal is investigating some construction alternatives to enhance flat slab ductility and deformability. The alternatives are: adding different types of punching-shear reinforcement, using discreet fibers in concrete mixes, and increasing thickness of slab around columns. The experimental study included preparation and testing of seven half-scale interior slab-column connections up to failure. The first specimen is considered a reference, the second two specimens made of concrete mixes with different volumetric ratios of polymer fibers. Another three specimens reinforced with different types of punching-shear reinforcement, and the last specimen constructed with drop panel of inverted pyramidal shape. It is found that using the inverted pyramid-shape drop panel of specimen, increases the punching-shear capacity, and the initial and the post-cracking stiffnesses. The initial elastic stiffnesses are different for all specimens especially for the slab with closed stirrups where it is experienced the highest initial stiffness compared to the reference slab.