• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.025 seconds

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.

Experimental study of the air emission effect in the tangential and the multi-stage spiral inlet (접선식 유입구와 다단식 나선 유입구의 공기 배출 효과에 관한 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.235-243
    • /
    • 2019
  • Recently, urban inundation was frequently occurred due to the intensive rainfall exceeding marginal capacity of the flood control facility. Furthermore, needs for the underground storage facilities to mitigate urban flood are increasing according to rapidly accelerating urbanization. Thus, in this study, drainage efficiency in drain tunnel connecting to underground storage was investigated from the air-core measurements in the drop shaft against two types of inlet structure. In case of the spiral inlet, the multi-stage structure is introduced at the bottom of the inlet to improve the vortex induction effect at low inflow discharge (multi-stage spiral inlet). The average cross-sectional area of the air-core in the multi-stage spiral inlet is 10% larger than the tangential inlet, and show the highly air emission effect and the highly inflow efficiency at the high inflow discharge. In case of the tangential inlets, the air emission effect decreased after exceeding the maximum inflow discharge, which is required to maintain the inherent performance of the tangential inlet. From the measurements, the empirical formula for the cross-sectional area of the air-core according to locations inside the drop shaft was proposed in order to provide the experimental data available for the inlet model used in experiments.

Study on Estimation Method of Water Cycle Goal in Waterfront City (수변도시의 물순환 목표 산정 방안 연구)

  • Kim, Jae-Moon;Baek, Jong-Seok;Shin, Hyun-Suk;Park, Kyoung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.475-487
    • /
    • 2020
  • The current water-management paradigm is changing from the expansion of reservoirs and facilities for simple outflows and non-point source management to the building of a sound water circulation system throughout the watershed. Based on this, water management for the watershed as a whole is establishing standards through local ordinances. The purpose of this study is to establish water cycle targets that are resilient to water management even after the development of cities in watersheds where water management is highly needed. This was done by referring to research and ordinances related to water circulation by local governments. A method is proposed based on a storage and infiltration method for rainfall. Through a comparison of percentiles, it was found that the water circulation target of a planned waterside city can be treated with 52% of total rainfall and 80% of rainfall of 17 mm per day. To quantitatively improve the quality results of these calculation procedures, it is estimated that the calculation of water cycle targets will be more reliable if other various variables such as the safety of low impact development factors or the selection of appropriate specifications are considered later.

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

Necessity of Quality Control for Aviation Fuel(Jet A-1) to Secure Aviation Safety (항공안전 확보를 위한 항공유(Jet A-1) 품질관리 필요성)

  • Junbeom Heo;Yumi Kang;Heejin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.194-199
    • /
    • 2024
  • Accidents due to aircraft fuel defects rank in the top 13 of the 34 accident types described by CAST-ICAO Common Taxonomy Team(CICTT). Aircraft accidents occur because of the inflow of moisture or pollutants depending on the distribution process and storage environment. To confirm the change in physical properties of the aircraft oil stored for a long time, we stored JET A-1 aircraft oil in a metal can to observe the change after six months. We confirmed that the aircraft oil stored for a long time satisfied the quality standards, and the stability of the fuel oil was high. However, in scenarios in which aircraft oil is stored separately on ships, onshore storage facilities, oil fields, etc., owing to the nature of missions, such as in marine police aircraft, the inflow of moisture or pollutants may likely occur due to changes in the internal and external environment. In addition, pollutants can be analyzed using existing tests and distillation properties, but for moisture, domestic and international standards and domestic laws determine the moisture separation ability of aircraft oil through the water separation index, but the moisture content is not analyzed. Therefore, aviation safety must be secured by adding quality control standards for moisture content and performing revisions to uniformize domestic and international standards and laws.

Detection of Potential Flow Paths of Leaked CO2 from Underground Storage Using Electrical Resistivity Survey (전기비저항탐사 방법에 의한 지중 저장 이산화탄소 누출 가능 경로 탐지)

  • Lim, Woo-Ri;Hamm, Se-Yeong;Hwang, Hak-Soo;Kim, Sung-Wook;Jeon, Hang-Tak
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.69-79
    • /
    • 2018
  • The Korean government attempts to reduce $CO_2$ emissions by 37% to 314.7 Mt $CO_2$, down from the estimated 850.6 Mt $CO_2$ until 2030 in order to confront green house effect. In this context, in 2014, Korean government launched $CO_2$ Storage Environmental Management Research (K-COSEM) Center for carrying out pilot-scale research on $CO_2$ leakage from underground $CO_2$ storage facilities. For the detection of $CO_2$ leakage, it is necessary to identify hydrologeological and geophysical characteristics of the subject area. In the study site of Naesan-ri, Daeso-myeon, Eumseong-gun, Chungbuk Province, two times injection tests (June 28-July 24, 2017 and August 07-September 11, 2017) of $CO_2$ and $SF_6$ dissolved waters, respectively, was conducted to understand the leakage behavior of $CO_2$ from underground. The injection well was drilled to a depth of 24 m with a 21-m casing and screen interval of 21~24 m depth. Two times resistivity surveys on August 18, 2017 and September 1, 2017, were conducted for revealing the flow of the injected water as well as the electrical properties of the study site. The study results have shown that the high-resistivity zone and the low-resistivity zone are clearly contrasted with each other and the flow direction of the injected water is similar to natural groundwater flow. Besides, the low resistivity zone is widely formed from the depth of injection to the shallow topsoil, indicating that the weathered zone of high permeability has high $CO_2$ leakage potential.

Effectiveness Evaluation of the Bogie Exchange and the Automatic Variable Gauge System using LCC Analysis (LCC 분석을 이용한 대차교환과 자동궤간가변 시스템의 효율성 평가)

  • Chung, Kwang-Woo;An, Joon-Yong;Kim, Chul-Su;Na, Hee-Seung
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.334-342
    • /
    • 2012
  • It is connected with various gauges existing in Euro-Asian continents. Such differences impedes the operation seriously as on the contact of railway tracks of different gauge the cargo must be either transshipped or the running assemblies of rail vehicles must be exchanged. Those operations are costly, time-consuming and require extended infrastructure together with very expensive storage and transshipment facilities at border-crossing point. Moreover, those operations extend transportation time considerably. Therefore, effectiveness of railway transportation systems significantly depends on track gauge change 1435/1520mm, which connects with complicated handling-shifting operations. The paper concerns assessment of effectiveness in strategical rail systems with gauge changing. The paper presents short description of transport system with gauge changing and initial assessment of shifting technologies. Method of system assessment comparison based on Life Cycle Cost model is described here as well.

A Basic Study on the Variability of Indoor Spaces for Local Children's Centers - Focused on the Analysis of Design Guideline - (지역아동센터 실내공간 가변방안을 위한 기초연구 - 디자인가이드라인 사례분석을 중심으로 -)

  • Kim, Mi-Young;Moon, Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • Although the government has revised the child welfare act, institutionalized the establishment of local children's centers, and given financial support for them, there are a number of problems with respect to their operation. Specifically, one of main problems is their limited space. Diverse problems that go with the arrangement of limited space and usability have occurred, however there are only a few strategies to use limited space flexibly. This study assumed variability as one of the methods to solve spatial problems. As a basic research for the assumption, Analyzing the variable method and characteristics of domestic and foreign child-care facility guidelines was performed trying to take advantage of as a basic data in order to seek a variable scheme of local children centers' indoor space. For this purpose, study analysed the methods and characteristics of variability centering on aspects related to variability which are environmental design elements required by local children's centers as suggested in previous studies. The results are as follows. First, the variability of space should be planned according to activity and time, and consider the methods of division, storage, and other facilities necessary. Second, methods of variability in space can be classified into creating areas and structures that are variable. Third, as a result of analysing the environmental design elements required by local children's centers, this study discovered the following characteristics: multi-purpose usability through a combination of variable devices, transition through a variable space medium and setting up areas and expansion of indoor variability assuming usability through internal and external connections.

A Time-series Analysis of the Influence Factors on Public Library Patron Numbers (공공도서관 고객 규모의 영향요인에 대한 시계열분석)

  • Lee, Kyeong-Jin;Song, Myung-Gyu
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.54 no.4
    • /
    • pp.195-220
    • /
    • 2020
  • This study aims at identifying the influence factors on public library patron numbers through a time-series analysis using the Korean National Libraries Statistical Data from 2014 to 2019. The facts found can be summarized as follows; First, the variables of books collection and periodicals appeared constantly to be unsignificant in the influence on public library patron numbers through the period from 2014 to 2019. This suggests that the internet may be substituting public libraries in the service of access to ordinary books and periodicals, which has been considered as a main function of public libraries. Second, such factors as cultural or books programs, library operation, user activities, and facilities turned out to be more significant and continual in the influence on public library patron numbers than the factor of books collection and storage. This means that public libraries have a complementary relation with the internet in these fields.

Physiochemical Treatment of Feed and Utilization of Feed Additives to Control Salmonella in Poultry (가금의 살모넬라 제어를 위한 사료의 이화학적 처리와 사료첨가제의 활용)

  • Kim, Ji-Hyuk;Kim, Hack-Youn;Kim, Bong-Ki;Kim, Gye-Woong
    • Korean Journal of Poultry Science
    • /
    • v.45 no.1
    • /
    • pp.1-15
    • /
    • 2018
  • Salmonella infections in livestock industry cause various problems such as worsening animal welfare and productivity, damaging consumer confidence in the food safety of animal products. Chicken meat and eggs are known as major source of pathogen causing human foodborne infections. Therefore food safety concerns have prompted the poultry producers and governments to introduce the strategy and regulation to control these pathogens. Salmonella can persist for long periods of time in a wide range of spaces including feed bin, feed processing facilities, poultry farm, slaughterhouse, processing plants, etc. For the effective and constant Salmonella control, combination of pre-harvest, harvest and post-harvest measures should be considered comprehensively. The control measures would be most effective at farm level where the contamination initiates. Transmission of pathogen from feed origin to the live poultry and finally to the products was proven already. To control bacteria in the feed ingredients and formula feed, thermal processing, irradiation or chemical treatment may be applied. Chemical treatments to inhibit Salmonella in the feed involve the use of products containing organic acids, formaldehyde, or a combination of such compounds. However, recontamination which might occur during storage and transport process and/or by other various factors should always be under control and eliminated. Feed additives used to control Salmonella in birds' gastrointestinal track can be of various types, including prebiotics, probiotics, organic acids and bacteriophages. Although their mode of action varies, they ultimately inhibit the colonization of Salmonella in the gut and improve the performance of birds. This review describes the strategies that could be adapted to the management of feedstuffs and the use of feed additives in pre-harvest stage to control Salmonella contamination in poultry farming.