• 제목/요약/키워드: Storage Model

검색결과 2,596건 처리시간 0.035초

유연 매체에 적용 가능한 Bimorph PZT 구동기의 설계 및 제어 (Design and Position Control of Bimorph PZT Actuator for Flexible Media)

  • 심현재;황현우;박노철;양현석;박영필
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.59-63
    • /
    • 2005
  • Nowadays, various approaches are performed to increase the storage capacity of optical storage device. One of the promising candidates is using the high NA lens. By using high NA lens, the beam spot size can be reduced which will lead to increase the storage density. This paper proposes a double cantilever beam type bimorph PZT actuator for fine motion that can control the gap between the flexible media and optical pickup which uses high NA lens. Mathematical model is derived by using Hamilton's principle and the model is verified by finite element analysis and experiment. Position controller is designed and its performance is evaluated by experiment.

  • PDF

에너지 저장장치를 이용한 마이크로그리드의 구현 (Implementation of Microgrid using Energy Storage System)

  • 이계병;손광명;장길수
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.248-254
    • /
    • 2010
  • This paper deals with implementation of the laboratory-scale microgrid using energy storage system. Also, this paper develops a simulation model of the microgrid with same parameters on the laboratory-scale microgrid using PSCAD/EMTDC. The experimental results show good agreement with the simulation results. This shows the validity of the simulation model. A valve regulated lead acid (VRLA) battery is used to store energy. Energy storage system with fast response is able to maintain power quality of sensitive load within the microgrid.

Modelling of a High Efficiency Refrigeration System with Heat Storage for Reverse Cycle Hot Gas Defrost

  • Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.175-181
    • /
    • 2007
  • A computer model of a high efficiency refrigeration system equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system) is presented. The model was developed based on both theoretical and empirical equations for the compressor, evaporator, condenser and the heat storage equipment. Simulations of the prototype system were carried out to investigate refrigeration system performance under various operating conditions during refrigeration cycles. The simulations of the evaporator during defrost cycles at 30 and $40^{\circ}C$ hot gas refrigerant temperature were also performed which resulted on shorter defrost time but only slight increase in defrost efficiency. These information on energy efficiency and the defrost time required are important in order to avoid excessive parasitic load and temperature rise of the refrigerated room.

파이프라인을 이용한 이산화탄소 수송에서 중간 저장 허브 선정 모델링 및 시각화를 위한 시뮬레이터 개발 (Development of a Simulator for the Intermediate Storage Hub Selection Modeling and Visualization of Carbon Dioxide Transport Using a Pipeline)

  • 이지용
    • 한국콘텐츠학회논문지
    • /
    • 제16권12호
    • /
    • pp.373-382
    • /
    • 2016
  • 이산화탄소 포집 및 저장 / 격리 (CCS) 기술은 많은 이산화탄소 저감 방법 중 이상적인 방법으로 주목 받고 있다. 이산화탄소를 포집해서 파이프라인을 통해 저장소까지 수송할 때, 저장소가 가까운 경우 직접 수송할 수도 있지만, 중간 저장의 역할을 하는 허브를 거쳐 수송할 수도 있다. 허브의 수와 위치를 결정하는 것은 중요한 문제이다. 다목적 의사 결정을 위한 수학 모델은 많은 제약식과 목적식을 수반하는데, 문제의 계산 복잡도가 증가하지만 항상 최적을 보장하지 않는다. 본 연구에서는, 이산화탄소 수송망에서 중간 저장 허브의 위치와 수를 결정하는 알고리즘을 제안하고, 이를 활용하여 이산화탄소 발생지의 연결 네트워크 시뮬레이터를 개발한다. 시뮬레이터에서는 또한 이산화탄소의 수송 경로를 제공한다. 사례 연구로 한국에 모델을 적용한다.

Performance Analysis of Virtual Storage

  • Wei, X;RO, CheulWoo
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2018년도 춘계 종합학술대회 논문집
    • /
    • pp.511-512
    • /
    • 2018
  • Virtual machine technology enables multiple hosts to share the same LUN(Logical Unit Number) and the same storage, but if too many hosts share the same LUN, it will increase the delay. In this paper we propose a performance model, get several values of scalable storage performance in virtual environment, and present the results examined the effects of I/O queuing in a virtual infrastructure. This results show how to make the most effective use of our storage resources.

  • PDF

사용후 연료 건식저장용기 1/8규모 축소모형 지진회전응답해석 (Seismic Rocking Response Analysis of 1/8 Scale Model for a Spent Fuel Storage Cask)

  • 이재한;서기석;구경회;조천형;최병일;이흥영;염성호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.383-389
    • /
    • 2005
  • This research is to develop a seismic response analysis method for a spent fuel storage cask. FEM model is built for the test model of 1/8 scale spent fuel dry storage cask using available 3D contact conditions in ABAQUS/Explicit. Input load for this analysis os a seismic wave of El-centro earthquake, and the friction and damping coefficients in the analysis condition we obtained from the test result. Penalty and kinematic contact methods of ABAQUS are used for mechanical contact formulation. The analysis method was verified for rocking angle obtained by seismic response tests. The kinematic contact method with an adequate normal contact stiffness showed a good agreement with tests.

  • PDF

유입량에 따른 빈도별 저수용량 결정에 관한 연구 (A Study on Determination of Frequency Storage Capacities by Inflows)

  • 최한규;최용묵;전광제
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.131-138
    • /
    • 2000
  • A past monthly data is not faithful so much for a short term. But, the stochastic generation technique was provide of a long-term data. Thus this study is used a data which generated a monthly inflow amounts data by Thomas-Fiering model. This model is needed a certain process which determination of distribution, decision of continuous durability, etc. It was generated a inflow data every one month as Thomas-Fiering method. The generated inflow data was used input data for a monthly cumulative analysis. This analysis obtained a storage capacities which would be required during droughts having various return periods. It was presented a equation of fitting regression that was carried out regression analysis of 5, 10, 20, 50 years period.

  • PDF

Simultaneous Planning of Renewable/ Non-Renewable Distributed Generation Units and Energy Storage Systems in Distribution Networks

  • Jannati, Jamil;Yazdaninejadi, Amin;Talavat, Vahid
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.111-118
    • /
    • 2017
  • The increased diversity of different types of energy sources requires moving towards smart distribution networks. This paper proposes a probabilistic DG (distributed generation) units planning model to determine technology type, capacity and location of DG units while simultaneously allocating ESS (energy storage systems) based on pre-determined capacities. This problem is studied in a wind integrated power system considering loads, prices and wind power generation uncertainties. A suitable method for DG unit planning will reduce costs and improve reliability concerns. Objective function is a cost function that minimizes DG investment and operational cost, purchased energy costs from upstream networks, the defined cost to reliability index, energy losses and the investment and degradation costs of ESS. Electrical load is a time variable and the model simulates a typical radial network successfully. The proposed model was solved using the DICOPT solver under GAMS optimization software.

자동창고 Effectiveness 시스템에서 크기가 다른 저장단위를 고려한 모듈화 셀을 갖는 랙의 효과 (The of Rack with Modularized Cell considering Heterogeneous Unit Load Size in AS/RS)

  • 이문환;이영해
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2000
  • In general, under the concept of unit load, Automated Storage/Retrieval Systems (AS/RS) have the rack of equal sized cells. However, they are inadequate and inefficient meeting the various sizes of customers' demands in today's business environment. Higher utilization and flexibility of warehouse storage can be achieved by using AS/RS with tile rack of modularized cell. In this paper, the model of AS/RS with the rack of modularized cell is proposed, and the effectiveness of proposed model is presented by way of numerical examples. The model developed in this research, as one type of AS/RS that is more flexible to the size and has higher space utilization than those of existing rack structure, could every useful for the storage of heterogeneous unit load sizes.

  • PDF