• Title/Summary/Keyword: Step ratio

Search Result 1,593, Processing Time 0.029 seconds

Electrical Characteristics of Disk-type Piezoelectric Transformer Poled with the Same Direction (동일 방향으로 분극된 디스크형 압전변압기의 전기적 특성)

  • 이종필;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.688-692
    • /
    • 2003
  • For high voltage operation, a new type of piezoelectric transformer using radial vibration of disk, poled with the same direction was proposed. The piezoelectric ceramics was composed to PZT-PMN-PSN. The diameter and thickness of a disk type piezoelectric transformer were 45[mm]and 4[mm], respectively The surface ratio of driving electrode and generating electrode of the piezoelectric transformer was 2 : 1. The resonance characteristics of input admittance, step-up voltage ratio and power transmission efficiency of the piezoelectric transformer were measured by varying the load resistance(0.1∼70[kΩ]). As a result, both resonance frequency and step-up voltage ratio increased with increasing load resistance. The step-up voltage ratio was reached more than 60 times under no load resistance. The maximum efficiency of 97% at load resistance of 2kΩ was obtained.

Measurement Range Extension of AC High Voltage using two 200 kV Capacitive Dividers (200 kV 용량형 분압기 2대를 이용한 교류 고전압 측정범위 확장)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Jeong, Jin-Hye;Han, Sang-Ok;Joung, Jong-Man
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • The output voltage value of AC high voltage source has been usually obtained by multiplying low voltage value measured at both terminals of low voltage resistor by the dividing ratio of the high voltage capacitive divider. From the dividing ratio determined of each 200 kV capacitive divider, we have developed step-up method for measuring the output voltage up to 400 kV using two same type of 200 kV capacitive dividers connected in series. The theoretical dividing ratio of 400 kV capacitive dividers connected in series coincides with that of manufacturer's certification within measurement uncertainty. Thus, this developed step-up method makes it possible to extend the range of output voltage from 200 kV to 400 kV. Furthermore, The dividing ratio of divider under test obtained using this step-up method is consistent with that obtained using one 200 kV high voltage divider within corresponding uncertainties.

An Experimental Study on the Shift Characteristics of a Metal Belt Type Continuously Variable Transmission (CVT) (금속벨트식 무단변속기(CVT)의 변속특성에 관한 실험적 연구)

  • 이충섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.36-43
    • /
    • 1997
  • To cope with quest to improve the fuel economy and vehicle performance, Continuously Variable Transmission with Changing the speed ratio between minimum and maximum ratio by infinite step, is more efficient than conventional multi-ratio transmission. In this paper, to investigate a specific CVT shift ratio diagram and CVT shift characteristics, CVT vehicle was tested on the proving ground and chassis dynamometer. The test results are as follows; CVT can obtain the excellent vehicle performance and fuel economy changing the shift ratio by infinite step, without rapid change of engine revolution and driving force. And CVT can set up a special shift range that obtains not only the engine brake effect but also the maximum speed driving.

  • PDF

Enhancement of the Box-Counting Algorithm for Fractal Dimension Estimation (프랙탈 차원 추정을 위한 박스 계수법의 개선)

  • So, Hye-Rim;So, Gun-Baek;Jin, Gang-Gyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.710-715
    • /
    • 2016
  • Due to its simplicity and high reliability, the box-counting(BC) method is one of the most frequently used techniques to estimate the fractal dimensions of a binary image with a self-similarity property. The fractal calculation requires data sampling that determines the size of boxes to be sampled from the given image and directly affects the accuracy of the fractal dimension estimation. There are three non-overlapping regular grid methods: geometric-step method, arithmetic-step method and divisor-step method. These methods have some drawbacks when the image size M becomes large. This paper presents a BC algorithm for enhancing the accuracy of the fractal dimension estimation based on a new sampling method. Instead of using the geometric-step method, the new sampling method, called the coverage ratio-step method, selects the number of steps according to the coverage ratio. A set of experiments using well-known fractal images showed that the proposed method outperforms the existing BC method and the triangular BC method.

The Effect of Height Increase Elevator Shoes Insole on Gait and Foot Pressure (키높이 깔창이 성인남성의 보행 및 발의 압력분포에 미치는 영향)

  • Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.2
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of 0cm, 2.5cm, 5cm height increase elevator shoes insole on gait and foot pressure Methods: Fifteen young adult were recruited this study. Gait and foot was measured by Gait AnalyzerTM(Tech Storm Inc. korea). Statistical analysis was used one-way ANOVA to know difference between 0cm, 2.5cm insole and 5cm insole Results: There was no significantly difference on foot length, foot width, foot angle, step time during gait. But step length and step width was significantly difference during gait. There was no significantly difference on gait ratio during stance phase. There was significantly difference on forefoot pressure and rearfoot pressure ratio. Conclusion: These results indicate that height increase elevator shoes insole may be caused step length, step width decreaseed during gait. It caused forefoot pressure increased and rearfoot pressure decreased on foot.

A Study on the Desulfurization Efficiency as a Variation of Flow Field Applyed a Mixing Enhancement Apparatus (혼합촉진장치 적용시 유동장 변화에 의한 탈황효율 연구)

  • Chung, J.D.;Kim, J.W.;SeomMun, J.
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.177-181
    • /
    • 2010
  • This paper has designed a mixing enhancement apparatus called Lobed-plate and Step-plate and comparatively calculated desulfurization efficiency of when its shape was changed. The parameters used at this time were the shape, SR ratio and the number of nozzles of the mixing enhancement apparatus and comparatively analyzed desulfurization efficiency according to these parameters. As a result, the Step-plate appeared as more highly by around 4% than Lobed-plate in desulfurization efficiency according to the shape of the mixing promotion apparatus, and when the desulfurization efficiency as a SR ratio is considered, it appeared highly by an average of 5% when the SR ratio is 3 rather than 2. As a result of comparing desulfurization efficiency by fixing the SR ratio and setting the number of nozzles as 4 pieces and 6 pieces, there was no big change in desulfurization efficiency when the SR ratio is 2, but it could be confirmed to improve by around 5% when the SR ratio is 3 when time passed 8 seconds.

Effects of damping ratio on dynamic increase factor in progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.677-690
    • /
    • 2016
  • In this paper, the effect of damping ratio on nonlinear dynamic analysis response and dynamic increase factor (DIF) in nonlinear static analysis of structures against column removal are investigated and a modified empirical DIF is presented. To this end, series of low and mid-rise moment frame structures with different span lengths and number of storeys are designed and the effect of damping ratio in DIF is investigated, performing several nonlinear static and dynamic analyses. For each damping ratio, a nonlinear dynamic analysis and a step by step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived. The results of the analysis reveal that DIF is decreased with increasing damping ratio. Finally, an empirical formula is recommended that relates to damping ratio. Therefore, the new modified DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of moment frame buildings with different damping ratios.

Estimation of volume Ratio according to Step up Filling Method for a Dredged Clay (단계투기법에 의한 준설점토의 체적비 산정)

  • Lee, Song;Kang, Myoung-Chan
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.167-178
    • /
    • 2000
  • An experimental study on step up filling method is carried out to reinforce the Yano method which is widely used to estimate volume ratio and self-weight consolidation settlement in reclamation area. This method considers actual reclamation construction in which dredged clay is continuously filled and rising of deposit height is presented as a result of volume decrease by height rising and self-weight consolidation. It measured the relationship between filling velocity and deposit rising velocity; calculated the total filling height which is needed to achieve the planned final deposit height, and its solid height and the time which is taken to finish the planned final deposit height; and on the basis of these calculated parameters, predicted the self-weight consolidation and volume change ratio in reclamation construction. Yano method is also used to predict the same conditions. 29.8% in self-weight consolidation, 31.1% in volume ratio, 40% in void ratio and water content is underestimated in Yano method compared to step up filling method.

  • PDF

Case Study of the Immediate Gait Improvement in a Post-Stroke Gait Disturbance Patient Equipped with a Weighted Vest (중량조끼를 착용한 뇌졸중으로 인한 보행장애 환자의 즉각적인 보행 개선 효과 1례)

  • Kim, Cheol-hyun;Hong, Hae-jin;Lee, Sang-kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.5
    • /
    • pp.763-769
    • /
    • 2016
  • Objective: To confirm the immediate gait improvement in a post-stroke gait disturbance patient equipped with a weighted vest. Methods: We selected a patient who was able to walk without another’s help or with tools. The selected patient had an unstable gait because she had only started an independent gait within the past week, so we thought that a weighted vest could be very helpful for her. We first collected gait parameters using a treadmill gait analysis system while the patient walked on the treadmill without the weighted vest. After a 10-minute break, gait parameters were collected again while the patient walked on the treadmill while wearing the weighted vest. The gait parameters we collected included step length (cm), stance phase (%), swing phase (%), SW/ST, and gait line length (mm). For objective evaluation of gait improvement, we calculated the ratio of gait parameters of the right and left limbs. Results: The gait of the post-stroke patient was more symmetrical when wearing the weighted vest than without the weighted vest. Without the weighted vest, her step length ratio was 0.78, stance phase ratio was 0.88, swing phase ratio was 1.50, SW/ST ratio was 1.70, and gait line length ratio was 0.91. With the weighted vest, her step length ratio was 0.88, stance phase ratio was 0.90, swing phase ratio was 1.38, SW/ST ratio was 1.54, and gait line length ratio was 0.98. No side effects were observed due to the weighted vest.

Three Dimensional Finite Element Analysis for Piezoelectric Transformer

  • Joo, Hyun-Woo;Lee, Chang-Hwan;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.98-103
    • /
    • 2001
  • This paper presents the numerical analysis of piezoelectric devices using three-dimensional finite element analysis. The characteristic of piezoelectric transducer, such as mechanical displacement and electrical are analyzed and the validity is confirmed by experiments Applying the finite element routine to a piezoelectric transformer, the resonance features electrical impedance. the ratio of step-up voltage and vibration mode of piezoelectric transformer are calculated numerically By using three-dimensional finite element method effects of width variation to resonance features, electrical input impedance and the voltage step-up ratio for a piezoelectric transformer, can be considered in design procedure.