A Study on the Desulfurization Efficiency as a Variation of Flow Field Applyed a Mixing Enhancement Apparatus

혼합촉진장치 적용시 유동장 변화에 의한 탈황효율 연구

  • 정진도 (호서대학교 환경공학과) ;
  • 김장우 (호서대학교 그린에너지반도체공학부) ;
  • 서문준 (호서대학교 대학원 반도체디스플레이공학과)
  • Received : 2010.09.27
  • Accepted : 2010.12.15
  • Published : 2010.12.31

Abstract

This paper has designed a mixing enhancement apparatus called Lobed-plate and Step-plate and comparatively calculated desulfurization efficiency of when its shape was changed. The parameters used at this time were the shape, SR ratio and the number of nozzles of the mixing enhancement apparatus and comparatively analyzed desulfurization efficiency according to these parameters. As a result, the Step-plate appeared as more highly by around 4% than Lobed-plate in desulfurization efficiency according to the shape of the mixing promotion apparatus, and when the desulfurization efficiency as a SR ratio is considered, it appeared highly by an average of 5% when the SR ratio is 3 rather than 2. As a result of comparing desulfurization efficiency by fixing the SR ratio and setting the number of nozzles as 4 pieces and 6 pieces, there was no big change in desulfurization efficiency when the SR ratio is 2, but it could be confirmed to improve by around 5% when the SR ratio is 3 when time passed 8 seconds.

Keywords

References

  1. 홍진표, "배연탈황 기술 현황 및 개발방향", 기계저널, Vol. 40 No. 7, 2000, pp. 40-44.
  2. 손한호, "화력발전소 배연탈황설비 및 기술에 관한 연구", 진주산업대학원, 2005, pp. 2-10.
  3. Jin-do Chung, Jang-woo Kim, Byung-hwan Kim and Young-moon Park, "Numerical analysis for improving of SOx removal efficiency in the DSI(Dry Sorbent Injection Technology) of FGD system(1)", Korea Society of Environmental Engineers, Vol. 29 No.1, 2007, pp. 47-53.
  4. Paul S. Nolan, "Flue Gas Desulfurization Technologies for Coal-Fired Power Plants", Coal-Tech 2000 International Conference, 2000.
  5. 박재만, 신창섭, "소석회를 사용한 In-duct형 건식탈황공장의 최적화와 첨가재의 영향", 한국산업안전학회지, Vol. 12 No. 2, 1997, pp. 102-110.
  6. Energy and Environmental research corporation, "Global approach for enhanced mass transger effects in duct flue gas desulfurization processes", DOE report No. DOE/PC/88873-T6, 1988.
  7. Rice, R. M., Bond, G. A., "Flue gas desulfurization by in-duct dry scrubbing using calcium hydroxide", AIChEJ, Vol. 36 No. 2, 1990, pp. 473-471. https://doi.org/10.1002/aic.690360318
  8. G. Aurora, A. M. Jose and I. Angel, "Mechanistic and non-linear modeling approaches to in duct desulfurization", Chemical engineering and processing, 2005, pp.709-715.
  9. C. Crowe, M. Sommerfield, and Tutaka Tsuji, "Multiphase flows with droplets and particles", CRC Press,1998.
  10. 정진도 김장우, Vortex에 의한 DSI공정 중 혼합효율 향상에 관한 연구, 한국액체미립화학회지, Vol. 14 No. 1, 2009.