• Title/Summary/Keyword: Statistical Testing

Search Result 1,201, Processing Time 0.028 seconds

A Study of Psychometric Function Curve for Korean Standard Monosyllabic Word Lists for Preschoolers (KS-MWL-P) (한국표준 학령전기용 단음절어표 (Korean Standard Monosyllabic Word Lists for Preschoolers, KS-MWL-P)의 심리음향기능곡선 연구)

  • Shin, Hyun-Wook;Kim, Jin-Sook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.534-541
    • /
    • 2009
  • Word recognition test (WRT) for the children can be useful for diagnosing the degree of communication disability, prescribing hearing instruments, planning aural rehabilitation and speech therapy, and determination of site of lesions. The Korean standard monosyllabic word lists for preschoolers (KS-MWL-P) were developed considering the criteria given by the literatures. However, the authors of KS-MWL-P suggested more children should be included to verify homogeneity of the lists using psychometric function curve since only 8 children participated in the developing process. The purpose of this study was to explore the homogeneity of KS-MWL-P for supplementing the limitations of the lists employing psychometric analysis. To 23 preschoolers who have normal-hearing, 100 monosyllabic KS-MWL-P words were examined with the pictures. Psychometric function curve with linear slopes of 20% and 80%'s correct rates through accounting recognition scores of each monosyllabic word at variable intensities from -10 to 40 dBHL was obtained and analyzed. As a result, s-shaped psychometric function curve was presented with increasing correct rate depending on intensity and showed no statistical significant differences among each word and list. The congruous graph shapes among lists also indicated good homogeneity and the list 1,2,3,4's average slopes were 4.48, 3.86, 4.65, 4.50. It was verified that the homogeneity was suitable because the analysis of variance showed no statistical significance among lists (p>0.05). However, KS-MWL-P's order of slope according to the order of the number of items, $1{\sim}10$, $1{\sim}20$, $1{\sim}25$ showed no difference with the p-value of 0.93, 0.59, 0.91, 0.70 for the lists 1,2,3, and 4, respectively. Although KS-MWL-P was assumed that the lower-numbered items were easy for testing younger ages, this study's results could not agree with the author's conclusion. Considering this matter, rearranging of the number of items should be performed according to the analysis of slope suggested by this study for testing younger children with easier items. Other than this, in conclusion, KS-MWL-P was proved to be useful for clinical and rehabilitative evaluating and training tools for preschoolers.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

An Application of Software Reliability Estimation Model on Weapon System (국내 무기체계 분야의 소프트웨어 신뢰성 추정 모델 적용 사례)

  • Bak, Da-Un
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.178-186
    • /
    • 2020
  • In the domain of Korean weapon system development, issues about software reliability have become crucial factors when developing a weapon system. There is a process required for weapon system software development and management that includes certain activities required to improve the reliability of software. However, these activities are biased toward static and dynamic analyses of source code and do not include activities necessarily required by the international standard. IEEE std. 1633-2016 defines a process for software reliability engineering and describes software reliability estimation as an essential activity in the process. Software reliability estimation means that collecting defective data during the test and estimating software reliability by using the statistical model. Based on the estimated model, developers could estimate the failure rate and make comparisons with the objective failure rate to determine termination of the test. In this study, we collected defective data and applied reliability estimation models to analyze software reliability in the development of a weapon system. To achieve objective software reliability, we continuously tested our software and quantitatively calculated software reliability. Through the research, we hope that efforts to include activities described by the international standard will be carried out in the domain of Korean weapon system development.

Understanding the Correlation Between Dorsiflexion Range of Motion and Dynamic Balance in Elderly and Young Adults (노인과 젊은 성인의 발목발등굽힘 관절가동범위와 동적 균형 상관성 대한 이해)

  • Seo, Hae-yong;Han, Ji-hye;Kim, Min-ju;Kim, Ah-yeon;Song, Yi-seul;Kim, Su-jin
    • Physical Therapy Korea
    • /
    • v.25 no.2
    • /
    • pp.22-29
    • /
    • 2018
  • Background: Deficits of both ankle dorsiflexion range of motion (DFROM) and dynamic balance are shown in persons with chronic ankle instability and the elderly, with the risk of falls. Objects: This study aims to investigate the relationship between DFROM and dynamic balance in elderly subjects and young adults. Methods: Fifty-nine subjects were divided into three groups: ankle stability young group (SY), ankle instability young group (IY) and ankle stability older group (SO). We recruited three old subjects with ankle instability, but excluded them during a pilot testing due to the safety issue. DFROM was measured by weight bearing lunge test (WBLT) and dynamic balance was measured via star excursion balance test (SEBT) in anteromedial, medial, and posteromedial directions. The group differences in WBLT and SEBT and each group's correlation between WBLT and SEBT were detected using the R statistical software package. Results: The dorsiflexion range of motion was significantly different between the SY, IY, and SO groups. The SO group showed the highest DFROM and IY group showed the lowest DFROM (SY: $45.88{\pm}.66^{\circ}$, IY: $39.53{\pm}1.63^{\circ}$, SO: $47.94{\pm}.50^{\circ}$; p<.001). However, the SO group showed the lowest dynamic balance score for all SEBT directions (SY: $87.24{\pm}2.05cm$, IY: $83.20{\pm}1.30cm$, SO: $77.23{\pm}2.07cm$; p<.05) and there was no relationship between the dorsiflexion range of motion and dynamic balance in any group. Conclusion: Our findings suggest that ankle DFROM is not a crucial factor for dynamic stability regardless of aging and ankle instability. Other factors such as muscle strength or movement coordination should be considered for training dynamic balance. Therefore, we need to establish the rehabilitation process by measuring and treating ROM, balance, and muscle strength when treating young adults with and without ankle instability as well as elderly people.

Antecedents and Consequence of Job Engagement: Focused on Food & Beverage Departments at Super Deluxe Hotels in Seoul (직무열의의 선행요인 및 결과변수에 관한 연구: 서울소재 특 1급 호텔 식음료 부서를 중심으로)

  • Kwon, Young-Guk;Yoon, Hye-Hyun
    • Culinary science and hospitality research
    • /
    • v.21 no.3
    • /
    • pp.212-231
    • /
    • 2015
  • This study aims to understand the relationships between antecedents (recognition, empowerment, fair rewards, procedural justice(PJ), perceived organizational support(POS) and consequence(turnover intention(TI) of job engagement in a super deluxe hotel's F&B departments. Based on a total of 402 useful samples obtained for the empirical research, this study reviewed reliability and fitness of the research model and verified total 6 hypotheses with through the use of the AMOS statistical program. The hypothesized relationships in the model were tested simultaneously by using a structural equation model(SEM). The proposed model provided an adequate fit to the data, ${\chi}^2=668.894$(p<.001), df=373, CMIN/DF=1.794, GFI=.901, AGFI=.877, NFI=.928, CFI=.967, RMSEA=.044. The model's fit, as indicated by these indexes, was deemed satisfactory, and thus provided a good basis for testing the hypothesized paths. The results show that recognition, empowerment, fair rewards, PJ, and POS had a positive significant influence on job engagement. In addition, job engagement had a negative significant influence on TI. Through this it was confirmed that an optimized organization(working) environment reduced employees' turnover intention by increasing their job engagement level. Therefore, it is suggested that F&B departments at super deluxe hotels design various internal marketing programs from the perspective of efficient human resource management. Implications and limitations, as well as future research directions are also discussed.

Link Travel Time Estimation and Evaluation of Applicability to Traffic Information Collection Based RFID Probe Data (RFID 기반의 통행시간 추정 기법 개발 및 교통정보수집 적용가능성 평가)

  • Shim, Sang-Woo;Choi, Kee-Choo;Lee, Kyun-Jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.15-25
    • /
    • 2007
  • This paper aims at testing the applicability of RFID (radio frequency identification) based link travel time estimation algorithm in urban street settings in Jeju island Korea. For this, we developed algorithm and compared link travel times derived from the RFID probe based algorithm with those from (already available) GPS based link travel time estimation algorithm and with the actual link travel times from survey. RFID readers are composed of master reader and slave reader and the participating passenger cars were supposed to be equipped with RFID tag inside the vehicle. The data were sent to traffic information center and we used those data in comparison. The algorithm produced link travel times in a successful manner and the accuracy of those link travel times was about 88%. For the same link segments, the accuracy of GPS based link travel times was 93%. The t-test showed that both RFID and GPS based link travel times were not different in accuracy from statistical point of view. The applicability of RFID was tested successfully and the algorithm proposed seemed to be used in similar urban settings. Some limits and future research agenda have also been presented.

  • PDF

Effect of Timing of Light Curing on the Shear Bond Strength of Three Self-adhesive Resin Cements

  • Yoo, Yeon-Kwon;Kim, Sung-Hun;Ryu, Jae-Jun;Ryu, Jae-Jun
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.28-34
    • /
    • 2008
  • Objectives. The objectives of this study were: 1) to compare the effect of varying timing of light curing on shear bond strength, and; 2) to compare the shear bond strength of three self-adhesive cements. Materials and methods. A total of 72 extracted non-carious teeth were divided into 24 for Unicem tests, 24 for Maxcem tests, and 24 for Biscem tests; they were assigned 3 * 2 subgroups of 12 teeth each. The specimens were prepared as follows: 1) The calculus and periodontal ligament were removed from the teeth; 2) The teeth were stored in normal saline; 3) The occlusal enamel of each tooth was removed using high-speed coarse diamond burs under water cooling, and; 4) Finally, the teeth were flattened by 600-grit silicone carbide paper disks. Resin blocks were adhered using either Unicem, Maxcem, or Biscem. Light curing timing was divided into two groups: U10, M10, and B10 were exposed to light after 10 seconds, and; U150, M150, and B150 on the other side were exposed to light after 150 seconds. Shear bond strength was measured by a Universal testing machine with cross head speed of 1mm/min. T-test and One way ANOVA were used for the statistical analysis of data. Results. The shear bond strength of U150 was not significantly higher than that of U10 (U150: 20.55.7Mpa, U10: 18.73.80Mpa). On the other hand, the shear bond strength of M150 was significantly higher than that of M10. The shear bond strength of B150 was also significantly higher than that of B10 (M150:14.45.7Mpa, M10: 9.94.2Mpa, B150: 24.38.3Mpa, B10: 17.27.3Mpa). When the light curing timing was 10sec after bonding, the shear bond strength of Unicem was highest; the shear bond strength of Biscem was highest when the light curing timing was 150sec after bonding (U10: 18.73.80Mpa, B150: 24.38.3Mpa). Significance. Since Unicem is less sensitive based on light curing timing, dentists seem to use it without considering the light curing timing. Maxcem showed the lowest bonding strength (especially M10). Thus, when using Maxcem, dentists need to delay the light curing after adhesion.

  • PDF

Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert

  • Joo, Han-Sung;Yang, Hong-So;Park, Sang-Won;Kim, Hyun-Seung;Yun, Kwi-Dug;Ji, Min-Kyung;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.183-190
    • /
    • 2015
  • PURPOSE. This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS. Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a $4.5{\times}10$ mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: $5-55^{\circ}C$, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS. The fracture loads were $539.28{\pm}63.11$ N (N5), $406.56{\pm}28.94$ N (N7), $366.66{\pm}30.19$ N (N9), $392.61{\pm}50.57$ N (A5), $317.94{\pm}30.05$ N (A7), and $292.74{\pm}37.15$ N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION. The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.

The Effect of Sensory Integration Program(Sensory Integration Therapy) after School on Functional Task Performance in School (방과 후 감각통합프로그램(감각통합치료)이 학교에서의 기능적 과제 수행에 미치는 효과)

  • Park, Ji-Hoon;Lee, Eun-Jung;Noh, Jong-Su;Lee, Hyang-Suk;Cha, Jung-Jin
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.8 no.1
    • /
    • pp.27-40
    • /
    • 2010
  • Objective : This study is designed to identify effect of a sensory integration(SI) program provided to elementary school students as an after-school activity. The study is looking at both occupational performance components and school-task performance which is an area of occupational performance. Methods : SI program specially designed as an after-school activity was provided to three boys who are first- or second grade students of Y elementary school in Dae-Jeon city. The SI intervention was organized with 25 sessions and carried out for two months. One group pretest-posttest design was used to evaluate the effectiveness of the SI program. Measurements used are Short Sensory Profile(SSP), K-DTVP-2, and BOTMP for occupational performance components, and School Function Assessment for functional schooltask performance. Results : It is found that posttest scores were enhanced in all assessments SSP; BOTMP; K-DTVP-2; and SFA. Conclusion : Results of this study simply propose that sensory integration program designed as after-school activity may have positive effects on not only occupational performance components but also on school-task performance of elementary school student. Since sample size is too small, however, there is limitation to find statistical significance. Further researches testing large number of subjects are required to boost the finding of this study.

  • PDF