• Title/Summary/Keyword: Static power

Search Result 1,523, Processing Time 0.031 seconds

Design of an Active Shaft Grounding System for the Elimination of Alternating Electromagnetic Field in Vessel (선체 교류 전자장 제거를 위한 능동 축 접지 시스템 설계)

  • Kim, Tae-kue;Ahn, Ho-kyun;Yoon, Tae-sung;Park, Seung-kyu;Kwak, Gun-pyong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1515-1524
    • /
    • 2015
  • Recently, for the purpose of preventing the corrosion of a vessel, the electrical corrosion protection device that prevents the corrosions of the hull and the propeller is widely used. However, the electrical corrosion protection method artificially emits the current into the seawater around the hull using the power supply in order to make the hull and propeller be in the state of not being corrosion, so that electromagnetic field is generated outside the hull by the current emitted into the seawater. In this paper, the static and alternating constituents of the electromagnetic field generated in underwater outside the hull are analyzed and a countermeasure is investigated to reduce the strength of the electromagnetic field. In conventional shaft grounding system, the shaft potential is maintained above at least 100mV and the alternating current component constitutes more than 10% of the total current. However, in this paper, a control system was designed in order that the alternating current component and the shaft potential which generate electromagnetic field are maintained within 1% and 2mV respectively, and the performance was verified by simulation.

Static and Dynamic Analysis of Reinforced Concrete Axisymmetric Shell on the Elastic Foundation -Effect of Steel on the Dynamic Response- (탄성지반상에 놓인 철근 콘크리트 축대칭 쉘의 정적 및 동적 해석(IV) -축대칭 쉘의 동적 응답에 대한 철근의 영향을 중심으로-)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.106-113
    • /
    • 1997
  • Dynamic loading of structures often causes excursions of stresses well into the inelastic range, and the influence of the geometric changes on the dynamic response is also significant in many cases. Therefore, both material and geometric nonlinearity effects should be considered in case that a dynamic load acts on the structure. A structure in a nuclear power plant is a structure of importance which puts emphasis on safety. A nuclear container is a pressure vessel subject to internal pressure and this structure is constructed by a reinforced concrete or a pre-stressed concrete. In this study, the material nonlinearity effect on the dynamic response is formulated by the elasto-viscoplastic model highly corresponding to the real behavior of the material. Also, the geometrically nonlinear behavior is taken into account using a total Lagrangian coordinate system, and the equilibrium equation of motion is numerically solved by a central difference scheme. The constitutive relation of concrete is modeled according to a Drucker-Prager yield criterion in compression. The reinforcing bars are modeled by a smeared layer at the location of reinforcements, and the steel layer model under Von Mises yield criteria is adopted to represent an elastic-plastic behavior. To investigate the dynamic response of a nuclear reinforced concrete containment structure, the steel-ratios of 0, 3, 5 and 10 percent, are considered. The results obtained from the analysis of an example were summarized as follows 1. As the steel-ratio increases, the amplitude and the period of the vertical displacements in apex of dome decreased. The Dynamic Magnification Factor(DMF) was some larger than that of the structure without steel. However, the regular trend was not found in the values of DMF. 2. The dynamic response of the vertical displacement and the radial displacement in the dome-wall junction were shown that the period of displacement in initial step decreased with the steel-ratio increases. Especially, the effect of the steel on the dynamic response of radial displacement disapeared almost. The values of DMF were 1.94, 2.5, 2.62 and 2.66, and the values increased with the steel-ratio. 3. The characteristics of the dynamic response of radial displacement in the mid-wall were similar to that of dome-wall junction. The values of DMF were 1.91, 2.11, 2.13 and 2.18, and the values increased with the steel-ratio. 4. The amplitude and the period of the hoop-stresses in the dome, the dome-wall junction, and the mid-wall were shown the decreased trend with the steel-ratio. The values of DMF were some larger than those of the structure without steel. However, the regular trend was not found in the values of DMF.

  • PDF

The Effectiveness of the IKDC Subjective Score in Clinical Outcome Study after Anterior Cruciate Ligament Reconstruction (전방 십자 인대 재건술 후 결과 판정에 있어 IKDC 주관적 점수의 유용성)

  • Kim, Ji-Yeong;Kim, Deuk-Won;Kim, Jin-Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.95-121
    • /
    • 2008
  • Purpose: The goal is to identify the effectiveness of the IKDC subjective score in the clinical outcome study after reconstruction of the anterior cruciate ligament. Materials and Methods: Twenty-four patients after ACL reconstructions using twelve hamstring autografts and twelve Achilles allografts were evaluated. Lysholm knee score, IKDC subjective score, Knee Outcome Survey score and Tegner activity score were evaluated for the subjective outcome value. Static instability tests, Biodex dynamometer and one-legged hop for distance tests were done for the objective outcome value. Three functional performance tests (FPTs) including Carioca test, Shuttle run test and Co-contraction test were performed for deciding the final results. Each scale was compared with FPTs results and Pearson's correlation test was used to test the correlation between the parameters. Results: IKDC subjective score, single hop test, and quadriceps power in low velocity of Biodex dynamometer tests had a positive correlation with the total FPTs results. Conclusion: IKDC subjective score can be an effective test to evaluate the functional status as well as the subjective outcome after ACL reconstruction.

  • PDF

An On-chip ESD Protection Method for Preventing Current Crowding on a Guard-ring Structure (가드링 구조에서 전류 과밀 현상 억제를 위한 온-칩 정전기 보호 방법)

  • Song, Jong-Kyu;Jang, Chang-Soo;Jung, Won-Young;Song, In-Chae;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.105-112
    • /
    • 2009
  • In this paper, we investigated abnormal ESD failure on guard-rings in the smart power IC fabricated with $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology. Initially, ESD failure occurred below 200 V in the Machine Model (MM) test due to current crowding in the parasitic diode associated with the guard-rings which are generally adopted to prevent latch-up in high voltage devices. Optical Beam Induced Resistance Charge (OBIRCH) and Scanning Electronic Microscope (SEM) were used to find the failure spot and 3-D TCAD was used to verify cause of failure. According to the simulation results, excessive current flows at the comer of the guard-ring isolated by Local Oxidation of Silicon (LOCOS) in the ESD event. Eventually, the ESD failure occurs at that comer of the guard-ring. The modified comer design of the guard-ring is proposed to resolve such ESD failure. The test chips designed by the proposed modification passed MM test over 200 V. Analyzing the test chips statistically, ESD immunity was increased over 20 % in MM mode test. In order to avoid such ESD failure, the automatic method to check the weak point in the guard-ring is also proposed by modifying the Design Rule Check (DRC) used in BCD technology. This DRC was used to check other similar products and 24 errors were found. After correcting the errors, the measured ESD level fulfilled the general industry specification such as HBM 2000 V and MM 200V.

Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection (반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Kim, Sin-Ae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.325-334
    • /
    • 2010
  • In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. A pushover analysis of the structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of the semi-rigid connection were adopted for the models. A fiber model was utilized for the moment-curvature relationship of the steel beam and the column, and a three-parameter power model was adopted for the moment-rotation angle of the semi-rigid connection. The top displacement, base-shear force, required ductility for the connection, sequence of the plastic hinge, and design factors such as the overstrength factor, ductility factor, and response modification coefficient were investigated using the pushover analysis of a 2D structure subjected to the equivalent static lateral force of KBC2005. The partial arrangement of the semi-rigid connection was found to have secured higher strength and lateral stiffness than that of the A-Semi frame, and greater ductility than the A-Rigid frame. The TSD connection was found suitable for use for economy and safety in the sample structure.

Design of an 1.8V 8-bit 500MSPS Cascaded-Folding Cascaded-Interpolation CMOS A/D Converter (1.8V 8-bit 500MSPS Cascaded-Folding Cascaded-Interpolation CMOS A/D 변환기의 설계)

  • Jung Seung-Hwi;Park Jae-Kyu;Hwang Sang-Hoon;Song Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.1-10
    • /
    • 2006
  • In this paper, an 1.8V 8-bit 500MSPS CMOS A/D Converter is proposed. In order to obtain the resolution of 8bits and high-speed operation, a Cascaded-Folding Cascaded-Interpolation type architecture is chosen. For the purpose of improving SNR, Cascaded-folding Cascaded-interpolation technique, distributed track and hold are included [1]. A novel folding circuit, a novel Digital Encoder, a circuit to reduce the Reference Fluctuation are proposed. The chip has been fabricated with a $0.18{\mu}m$ 1-poly 5-metal n-well CMOS technology. The effective chip area is $1050{\mu}m{\times}820{\mu}m$ and it dissipates about 146mW at 1.8V power supply. The INL and DNL are within ${\pm}1LSB$, respectively. The SNDR is about 43.72dB at 500MHz sampling frequency.

Load balancing Direction strategies in star network configurations (스타형 컴퓨터 네트워크의 부하균형방향 정책)

  • Im, Gyeong-Su;Kim, Su-Jeong;Kim, Jong-Geun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.427-437
    • /
    • 1994
  • Optimal static load balancing in star network configurations is considered. Three kinds of load balancing direction strategies are considered. First, a job arriving at the peripheral nodes may be processed either where it arrived(origin node) or transferred directly to central node Second, a job arriving at the central node may be processed there, or transferred to lightly loaded peripheral nodes. A nonlinear optimization problem is formulated. Using the optimal solution, an optimal load balancing algorithm is derived for the second load balancing strategy. Third a job arriving at the central node or a peripheral node may be processed either at origin node or transferred to another lightly loaded node (central or peripheral). A load balancing algorithm is derived for the third load balancing strategy. The effects of these three load balancing strategies are compared by numerical experiments. During the conduct of these in numerical experiments, several interesting phenomena were observed. The third load balancing strategy improved performance more than the first two other strategies. The second load balancing strategy, as a whole, resulted in only slightly improved performance. Finally, of the central node has larger processing power than the peripheral nodes, the first and third load balancing strategies produce equal performance improvement.

  • PDF

Modeling of Solid Circulation in a Fluidized-Bed Dry Absorption and Regeneration System for CO2 Removal from Flue Gas (연소기체로부터 CO2 회수를 위한 건식 유동층 흡수-재생 공정의 고체순환 모사)

  • Choi, Jeong-Hoo;Park, Ji-Yong;Yi, Chang-Keun;Jo, Sung-Ho;Son, Jae-Ek;Ryu, Chong Kul;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.286-293
    • /
    • 2005
  • An interpretation on the solid circulation characteristics in a fluidized-bed process has been carried out as a first step to simulate the dry entrained-bed absorption and bubbling-bed regeneration system for $CO_2$ removal from flue gas. A particle population balance has been developed to determine the solid flow rates and particle size distributions in the process. Effects of principal process parameters have been discussed in a laboratory scale process (absorption column: 25 mm i.d., 6 m in height; regeneration column: 0.1 m i.d., 1.2 m in height). The particle size distributions in absorption and regeneration columns were nearly the same. As gas velocity or static bed height in the absorption column increased, soild circulation rate and feed rate of fresh sorbent increased, however, mean particle diameter decreased in the absorption column. As cut diameter of the cyclone of the absorption column increased, solid circulation rate decreased, whereas feed rate of fresh sorbent and mean particle diameter in the absorption column increased. As attrition coefficient of sorbent particle increased, solid circulation rate and feed rate of fresh sorbent increased but mean particle diameter in the absorption column decreased.

A Study on the Design of Amplifier for Source Driver IC applicable to the large TFT-LCD TV (대형 TFT-LCD TV에 적용 가능한 Source Driver IC 감마보정전압 구동용 앰프설계에 관한 연구)

  • Son, Sang-Hee
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.51-57
    • /
    • 2010
  • A CMOS rail-to-rail high voltage buffer amplifier is proposed to drive the gamma correction reference voltage of large TFT LCD panels. It is operating by a single supply and only shows current consumption of 0.5mA at 18V power supply voltage. The circuit is designed to drive the gamma correction voltage of 8-bit or 10-bit high resolution TFT LCD panels. The buffer has high slew rate, 0.5mA static current and 1k$\Omega$ resistive and capacitive load driving capability. Also, it offers wide supply range, offset voltages below 50mV at 5mA constant output current, and below 2.5mV input referred offset voltage. To achieve wide-swing input and output dynamic range, current mirrored n-channel differential amplifier, p-channel differential amplifier, a class-AB push-pull output stage and a input level detector using hysteresis comparator are applied. The proposed circuit is realized in a high voltage 0.18um 18V CMOS process technology for display driver IC. The circuit operates at supply voltages from 8V to 18V.

Performance Analysis of Siding Window based Stream High Utility Pattern Mining Methods (슬라이딩 윈도우 기반의 스트림 하이 유틸리티 패턴 마이닝 기법 성능분석)

  • Ryang, Heungmo;Yun, Unil
    • Journal of Internet Computing and Services
    • /
    • v.17 no.6
    • /
    • pp.53-59
    • /
    • 2016
  • Recently, huge stream data have been generated in real time from various applications such as wireless sensor networks, Internet of Things services, and social network services. For this reason, to develop an efficient method have become one of significant issues in order to discover useful information from such data by processing and analyzing them and employing the information for better decision making. Since stream data are generated continuously and rapidly, there is a need to deal with them through the minimum access. In addition, an appropriate method is required to analyze stream data in resource limited environments where fast processing with low power consumption is necessary. To address this issue, the sliding window model has been proposed and researched. Meanwhile, one of data mining techniques for finding meaningful information from huge data, pattern mining extracts such information in pattern forms. Frequency-based traditional pattern mining can process only binary databases and treats items in the databases with the same importance. As a result, frequent pattern mining has a disadvantage that cannot reflect characteristics of real databases although it has played an essential role in the data mining field. From this aspect, high utility pattern mining has suggested for discovering more meaningful information from non-binary databases with the consideration of the characteristics and relative importance of items. General high utility pattern mining methods for static databases, however, are not suitable for handling stream data. To address this issue, sliding window based high utility pattern mining has been proposed for finding significant information from stream data in resource limited environments by considering their characteristics and processing them efficiently. In this paper, we conduct various experiments with datasets for performance evaluation of sliding window based high utility pattern mining algorithms and analyze experimental results, through which we study their characteristics and direction of improvement.