• 제목/요약/키워드: Standard variation

검색결과 1,552건 처리시간 0.03초

한국성우(韓國成牛)의 혈액학치(血液學値) 및 혈액화학치(血液化學値)에 관한 연구(硏究) 제2보(第二報) 한국성우(韓國成牛)의 혈액화학치(血液化學値)에 관한 연구(硏究) (Studies on the Hematology and Blood Chemistry of Korean Cattle Part II. Studies on the Blood Chemistry of Korean Cattle)

  • 정창국
    • 대한수의학회지
    • /
    • 제5권1호
    • /
    • pp.97-123
    • /
    • 1965
  • Observations were made on the blood picture of total 196 heads of healthy Korean cattles, including 98 males and females in the purpose of determination of blood chemical values and their sex differences and seasonal variations during one year period from December, 1963 to November, 1964. The blood sampling were scheduled by random in four different seasons and the sample size of both sex included in each season were designated to be same size. The ranges, averages or mean values of the blood glucose, total serum protein, serum globulin, serum albumin, total non-protein nitrogen, blood urea nitrogn, total serum cholesterol, serum inorganic phosphorus and serum calcium were determined in this studies and their respective standard deviation, standard error of means, sex differences and seasonal variations were as follows. 1. The blood glucose values for the male ranged from 32.8 to 70.0 mg/100cc. with a mean of $49.781{\pm}0.823mg/100cc$; for the female the range was 32.0 to 64.0mg/100cc. with a mean of $47.235{\pm}0.782mg/100cc$. Sex difference showed significant at 5% level and seasonal variation was highly significant at 1% level. 2. The total serum protein values for the male ranged from 5.61 to 8.83 gm/100cc with a. mean of $7.366{\pm}0.062gm/100cc$; for the female ranged from 5.53 to 8. 43 gm/100cc. with a mean of $6.832{\pm}0.063gm/100cc$. Sex difference and seasonal variation was not significant. 3. The serum globulin values for the male ranged from 2.97 to 4.78 gm/100cc. with a mean of $3.961{\pm}0.039gm/100cc$.; for the female ranged from 2.87 to 4.41 gm/100cc. with a mean of $3.699{\pm}0.037gm/100cc$. Sex difference showed highly significant at 1% level and seasonal variation was not significant. 4. The serum albumin values for the male ranged from 2.58 to 4.21 gm/100cc. with a mean of $3.405{\pm}0.029gm/100cc$.; for the female ranged from 2.39 to 4.10 gm/100cc. with a mean of $3.204{\pm}0.031gm/100cc$. Sex difference showed highly significant at 1% level and seasonal variation was not significant. 5. The total non-protein nitrogan values for the male ranged from 19.1 to 44.8 gm/100cc. with a mean of $31.166{\pm}0.582mg/100cc$.; for the female the range was 15.2 to 50.5 mg/100cc. with a mean of $28.89.6{\pm}0.673mg/100cc$. Sex difference showed significant at 5% level and seasonal variation was highly significant at 1 % level. 6. The blood urea nitrogen values for the male ranged from 6.4 to 28.3 mg/100cc. with a mean of $13.371{\pm}0.466mg/100cc$.; for the female the range, was 6.0 to 26.9 mg/100cc. with a mean of $13.631{\pm}0.321mg/100cc$. Sex difference was not significant and seasonal variation showed highly significant at 1 % level. 7. The total serum cholesterol values for the male ranged from 60.0 to 238.6 mg/100cc. with a mean of $140.897{\pm}2.826mg/100cc$.; for the female ranged from 50.0 to 243.0 mg/100cc. with a mean of $124.840{\pm}3.553mg/100cc$. Sex difference and seasonal variation showed highly significant at 1% level. 8. The serum inorganic phosphorus values for the male ranged from 3.5 to 7.8 mg/100cc. with a mean of $5.426{\pm}0.096mg/100cc$.; for the female ranged from 3.1 to 8.8 mg/100cc. with a mean of $5.570{\pm}0.128mg/100cc$. Sex difference and seasonal variation showed no significant. 9. The serum calcium values for the male ranged from 7.8 to 12.8 mg/100cc. with a mean of $10.761{\pm}0.102mg/100cc$.; for the female ranged from 8.0 to 13.0 mg/100cc. with a mean of 10. $756{\pm}0.097mg/100cc$. Sex difference was not significant and seasonal variation showed highly significant at 1% level. 10. The age of test group ranged from 2 years to 6 years in both sex and the averageage were, $4.45{\pm}0.114$ years in male and $4.50{\pm}0116$ years in female. Sex difference and seasonal variation of age were not found to be significant.

  • PDF

현장 표준양생 공시체 관리함의 개발에 관한 연구 (A Study on Development of Curing Apparatus for In-place Standard Curing Specimen)

  • 김경민;전충근;손성운;김기철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.97-100
    • /
    • 2004
  • In-place curing box for specimens is used to cure the compressive strength specimens for control in place concrete. The box if composed of insulating chamber maintaining 20$\pm$3$^{\circ}C$ of temperature, in this paper, strength and temperature history of specimens cured at in plate curing box are investigated to verify field applicability. According to test results, air temperature at measured time shows large temperature variation and below zero, whereas, inside temperature of in place curing box maintains within 20$\pm$3$^{\circ}C$ due to temperature control function. For curing condition. temperature of specimens cured at outside shows large temperature deviation. specimens lured at in-place curing box is not affected by outer temperature.

  • PDF

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Determination of ampicilin and colxacilin mixture by NMR

  • Shin, Moon-Hee;Park, Man-Ki;Yu, Chang-Hwa;Choi, Jung-Kap
    • Archives of Pharmacal Research
    • /
    • 제4권1호
    • /
    • pp.9-17
    • /
    • 1981
  • A simple, accurate and specific NMR procedure is described for the determination of amplicilin and cloxacillin mixtures in injection dosage form and capsules. The solvent was dimethysulfoxde $d_{6}$ and maleic acid was the internal standard. By integrating the peak at 2.68 ppm and 4.57 ppm, cloxacillin and ampicillin could be determined respectively. The relative proton ratio of ampicillin trihydrate and cloxacillin were 1.038 and 0.950. The coefficents of variation of amplicillin trihydrate and cloxacillin in a few commerical preparation were 1.55 % (n =9), 2.69 % (n =15).

  • PDF

부산 동삼동 지역의 지표오존농도 특성 연구 (A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan)

  • 전병일
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

Low Phase Noise CMOS VCO with Hybrid Inductor

  • Ryu, Seonghan
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권3호
    • /
    • pp.158-162
    • /
    • 2015
  • A low phase noise CMOS voltage controlled oscillator(VCO) for multi-band/multi-standard RF Transceivers is presented. For both wide tunability and low phase noise characteristics, Hybrid inductor which uses both bondwire inductor and planar spiral inductor in the same area, is proposed. This approach reduces inductance variation and presents high quality factor without custom-designed single-turn inductor occupying large area, which improves phase noise and tuning range characteristics without additional area loss. An LC VCO is designed in a 0.13um CMOS technology to demonstrate the hybrid inductor concept. The measured phase noise is -121dBc/Hz at 400KHz offset and -142dBc/Hz at 3MHz offset from a 900MHz carrier frequency after divider. The tuning range of about 28%(3.15 to 4.18GHz) is measured. The VCO consumes 7.5mA from 1.3V supply and meets the requirements for GSM/EDGE and WCDMA standard.

난류 유동 하에서 덕트 내의 착상 (Frost Formation in a Straight Duct under Turbulent Flow)

  • 양동근;이관수
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1114-1121
    • /
    • 2003
  • A mathematical model considering the air side and the frost layer is presented to predict the frost layer growth. The standard k-$\varepsilon$ model for the air flow and the diffusion and energy equations for the frost layer are employed. The numerical results are compared with experimental data to validate the present model, and agree well with experimental data within a maximum error of 10%. The present model predicts well the frost properties and heat and mass transfer with respect to the frosting time. The variation of total heat transfer strongly depends on the operating condition, and has a similar trend to that of the sensible heat transfer. The frost properties along the flow direction are also investigated.

The Suitability of European Designed Wind Turbines for the East Asian Market

  • Brown, G.R.D.;Barthelmie, R.J.;Kim, Hyun-Goo
    • 한국환경과학회지
    • /
    • 제18권8호
    • /
    • pp.825-831
    • /
    • 2009
  • A first step review is completed on the suitability of European designed wind turbines in an East Asia climate. Six parameters are chosen for detailed analysis of proper meteorological measures from flat, hilly, forested, coastal and offshore sites in West Europe and East Asia: mean wind speed, 10 minute mean wind speed distribution, turbulence intensity, wind shear, 3 second extreme wind speed and 10 minute direction change. All six parameters are assessed with a view for contrast with the wind turbine design standard IEC61400. The diurnal and seasonal variation, average and extreme values of each parameter are calculated where appropriate. Industry standard software and analysis techniques have been employed to assess the applicability of existing wind turbine design standards and design guidelines for the East Asian market.

자동차 범퍼금형에서의 게이트 형상이 제품 성형에 미치는 영향 (The effect of Gate type on Injection Molding of Automotive Bumper)

  • 황시현;지성대;김명기;권윤숙;정영득
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1724-1727
    • /
    • 2005
  • Injection molding process is one of the processes that can mold plastic product as low cost. However, manufacturing process of automobile bumper mold has lots of trial and error. Especially, desiging of a huge mold such as bumper mold is needed to establish a design standard for runner system. In this study, CAE was conducted to observe the variation of melt-flow by changing runner and gate type in automobile bumper mold as preceding study for a standard design of runner system.

  • PDF

건축공사비지수를 이용한 건설물가 변동분석 및 공사비 실적자료 활용방안 연구 (Forecasting of building construction cost variation using BCCI and it's application)

  • 조훈희;강경인;김창덕;조문영
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2002년도 학술대회지
    • /
    • pp.64-71
    • /
    • 2002
  • This research developed construction cost forecasting model using Building Construction Cost Index, time series analysis and Artificial Neural Networks. By this model, we could calculate the forecasted values of construction cost precisely and efficiently. And we also could find out that the standard deviation of forecasted values is 0.375 and it is a very exact result, so the standard deviation is just 0.33 percent of 112.28, the average of Building Construction Cost Index. And it show more exact forecasting result in comparison with Time Series Analysis.

  • PDF