• Title/Summary/Keyword: Standard solution

Search Result 1,929, Processing Time 0.032 seconds

Composition of Nutrient Solution for Endive(Cichorium endivia L.) Hydroponics (엔디브 양액재배에 적합한 배양액 조성)

  • 조영렬;이용범
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.123-129
    • /
    • 1998
  • This experiment was conducted to composition of nutrient solution for tore of endive hydroponics, and was compared the nutrient solution developed in the Seoul City University(SCUE) with the conventional solution of Proefstation voor Tuinbouw ender Glas. Proper compositions of nutrient solution for endive hydroponics were NO$_3$-N 15.0, NH$_4$-N 1.0, PO$_4$-P 3.0. K 10.0, Ca 5.0 and Mg 3.5 me.$\ell$$^{-1}$ , respectively SCUE and PTG standard nutrient solution showed slightly better yields among nutrient solutions. The SCUE nutrient solution and the PTG nutrient solution had no difference on growth and yield of endive Plants.

  • PDF

Determination of MTBE, TBA and BTEX in Soil by Headspace Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1693-1698
    • /
    • 2012
  • A headspace gas chromatographic mass spectrometric (GC-MS) assay method was developed for the simultaneous determination of methyl tertiary butyl ether (MTBE), $tert$-butyl alcohol (TBA) and benzene, toluene, ethyl benzene and xylene (BTEX) in soil contaminated with gasoline. 2 g of soil sample were placed in a 10 mL headspace vial filled with 5 mL of phosphoric acid solution (pH 3) saturated with NaCl, and the solution was spiked with fluorobenzene as an internal standard and sealed with a cap. The vial was heated in a heating block for 40 min at $80^{\circ}C$. The detection limits of the assay were 0.08-0.12 ${\mu}g$/kg for the analytes. For five independent determinations at 10 and 50 ${\mu}g$/kg, the relative standard deviations were less than 10%. The method was used to analyze fifty six soil samples collected from various regions contaminated with gasoline in Korea. The developed method may be valuable for the monitoring of the analytes in soil.

On the Optimum Site Assessments of a Structure by GIS (GIS에 의한 구조물의 최적 위치 결정 기법)

  • Yang, In-Tae;Kim, Yeon-Jun;Kim, Dong-Moon;Park, Jae-Hoon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.43-50
    • /
    • 1997
  • Local administration is closely related with intention of residents. Especially, a plan item is closely related with life of residents. Therefore, it has to be logical and objective solution for opinion convergence. Decision of opinion has to be in a triangular position standard and stand in a trio of criteria in standard. But, opinion convergence of residents very difficult. Recently, the technique of GIS presents method for oponion convergence with logical and objective and scientifically solution. And, this study present method for decision of intention to a complex element with GRID and NETWORK techniques of GIS. This study present optimun site of constructure with the GIS technique in consideration of a side face of transportation, technical, social economy and environments.

  • PDF

The Theoretical Life Prediction of Battery Disconnecting System for Electric Vehicle (전기자동차 베터리 차단장치의 이론적 수명 예측에 대한 연구)

  • Ryu, Haeng-Soo;Park, Hong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.864-865
    • /
    • 2011
  • Battery Disconnecting System (BDS) is the important equipment in electric vehicle system. Therefore, most of electric vehicle companies, i.e. Hyundai Motors, Renault Motors, General Motors, want to have the reliability of 15 years - 150, 000 miles. Recently, reliability prediction through Siemens Norm SN 29500 is considered without testing. In this paper, we will introduce the standard and various input parameters. Also the case study will be shown for BDS. Prediction model is constructed by listing all the components of BDS. It calculates the $\pi$ factors for each components using the conversion equation in the standard and converts the reference failure rates to the expected operating failure rates. According to the result, the parts which will be improved are EV-Relays.

  • PDF

Studies on Isolative Determination of dl- Methylephedrine hydrochloride from Complex Preparation (복합제제(複合製劑) 성분중(成分中) dl-Methylephedrine hydrochloride의 분리정량(分離定量))

  • Kim, Byung-Hi;Yong, Jae-Ick
    • Journal of Pharmaceutical Investigation
    • /
    • v.3 no.1_2
    • /
    • pp.5-15
    • /
    • 1973
  • Fluorometric determination of dl-Methylephedrine hydrochloride from complex preparation were studied. According to the experimental results and considerations obtained the results for the following. (1) dl-Methylephedrine hydrochloride in Hydrochloric acid media occurs the fluorescens by Picrolonic acid and Cuppric acetate. (2) The maximum absorption fluorescence wave length of dl-Methylephedrine hydrochloride standard solution is $365m{\mu}$. (3) The relationship between the fluorescence proportions to concentration of standard solution at range of $4.2{\times}10^{-4}\;M$. $6{\times}10^{-4}M$. (4) dl-Methylephedrine hydrochloride was precisely determined even in the presence of various components, especially Chloropheniramine maleate, Dextromethorphan hydrobromide and Diphenylhydramine hydrochloride. (5) This method has high sensitivity and is simple in precedure. (6) This method be applicable with 99.79% accuracy and was 99.5% in complex preparation.

  • PDF

NONTRIVIAL SOLUTIONS FOR BOUNDARY-VALUE PROBLEMS OF NONLINEAR FRACTIONAL DIFFERENTIAL EQUATIONS

  • Guo, Yingxin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.1
    • /
    • pp.81-87
    • /
    • 2010
  • In this paper, we consider the existence of nontrivial solutions for the nonlinear fractional differential equation boundary-value problem(BVP) $-D_0^{\alpha}+u(t)=\lambda[f(t, u(t))+q(t)]$, 0 < t < 1 u(0) = u(1) = 0, where $\lambda$ > 0 is a parameter, 1 < $\alpha$ $\leq$ 2, $D_{0+}^{\alpha}$ is the standard Riemann-Liouville differentiation, f : [0, 1] ${\times}{\mathbb{R}}{\rightarrow}{\mathbb{R}}$ is continuous, and q(t) : (0, 1) $\rightarrow$ [0, $+\infty$] is Lebesgue integrable. We obtain serval sufficient conditions of the existence and uniqueness of nontrivial solution of BVP when $\lambda$ in some interval. Our approach is based on Leray-Schauder nonlinear alternative. Particularly, we do not use the nonnegative assumption and monotonicity which was essential for the technique used in almost all existed literature on f.

Research on methods to extract standard head-related transfer function (표준 머리전달함수 추출 기법에 관한 연구)

  • Son, Daehyuk;Park, Youngjin;Jang, Sei-jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.572-574
    • /
    • 2014
  • Researches on three-dimensional multimedia has been performed actively in recent years. Virtual sound technology corresponding to virtual image should be provided to implement 3D multimedia with high quality. Head-related transfer function (HRTF) plays a key role in this research area. HRTFs measured in changing azimuth, elevation, and distance for each and every subject is necessary for ideal solution. However, it is practically impossible to measure all subjects' HRTFs, so various HRTF databases have been built by many researchers. Because HRTF displays quite different aspects from subject to subject, HRTF of dummy head has been used for generic usage. However, mannequin's HRTF showed much worse performance comparing with individual case so this solution should be improved. From previous work, standardization of HRTF based on tensor-singular value decomposition method has been proposed. For effective extraction of standard HRTF, three different decomposition methods are compared in this paper.

  • PDF

High Temperature Thermodynamics of Aqueous electrolyte Solutions (전해질 수용액의 고온 열역학)

  • Lee, Man Seung
    • Resources Recycling
    • /
    • v.27 no.2
    • /
    • pp.63-67
    • /
    • 2018
  • Gibbs free energy is a measure of relative stability among substances. Since the nature of the ions in aqueous solution is diverse, their thermodynamic data at extensive experimental conditions is scarce. In this work, the calculation procedure was introduced to obtain the absolute and conventional standard molar enthalpies and entropies of hydration of ions from the standard enthalpies and entropies of formation of hydrated ions. The application of correspondence principle to estimate thermodynamic data at high temperature was explained.

Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air (서울대기중 아질산기체의 계절별 농도변화)

  • 이용근;김종욱;이동수;백선영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

Application of activated carbon bugs to the dye tracer study in a Karst area

  • Hwang Hyeon-Tae;Lee Myeong-Jae;Choi Ye-Gwon;Mok Jong-Gu;Lee Jin-Yong;Kim Yong-Cheol;Yeom Byeong-U
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.407-410
    • /
    • 2006
  • Studies were performed on evaluating the applicability of activated carbon bugs on dye tracer tests as tracer detectors by using its adsorption isotherm of the grained activated carbon. We preliminary conducted several standard adsorption and extraction tests and obtained the relationship between standard dye solution and detected concentrations from activated carbon samples in dry and wet conditions. the slopes of the regression line were 0.71 for wet condition and 0.74 for dried one. Field dye tracer tests were performed in a karst area, where several faults occur along a stream and pass the test area. We sampled water samples and activated carbon samples at three points in Hwangji Pond, where groundwater outflows from the karst conduit. According to the results of breakthrough curve analysis, the regional flow along the conduit, which is assumed to cause a karst conduit, was estimated as 0.18 m/day. The relationship between the concentrations of water sample and extracted activated carbon bugs shows the similar slopes with those from standard solution tests. This suggests that activated carbon could be useful as a dye tracer detector because the extraced concentration can be quantified.

  • PDF