• Title/Summary/Keyword: Standard part

Search Result 2,563, Processing Time 0.03 seconds

Effect of Bias on the Pearson Chi-squared Test for Two Population Homogeneity Test

  • Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.5 no.4
    • /
    • pp.241-245
    • /
    • 2012
  • Categorical data collected based on complex sample design is not proper for the standard Pearson multinomial-based chi-squared test because the observations are not independent and identically distributed. This study investigates effects of bias of point estimator of population proportion and its variance estimator to the standard Pearson chi-squared test statistics when the sample is collected based on complex sampling scheme. This study examines the effect under two population homogeneity test. The standard Pearson test statistic can be partitioned into two parts; the first part is the weighted sum of ${\chi}^2_1$ with eigenvalues of design matrix as their weights, and the additional second part which is added due to the biases of the point estimator and its variance estimator. Our empirical analysis shows that even though the bias of point estimator is small, Pearson test statistic is very much inflated due to underestimate the variance of point estimator. In the connection of design-based variance estimator and its design matrix, the bigger the average of eigenvalues of design matrix is, the larger relative size of which the first component part to Pearson test statistic is taking.

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.975-982
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed 'adequate'. The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within-part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimates are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

  • PDF

Detection of Indication of Electric Accident in Simulated Electric Equipments Using Standard Deviation and Probability Distribution (표준편차와 확률분포를 이용한 모의전기설비에서 사고징후 검출)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.11-16
    • /
    • 2009
  • This paper describes a detecting method for indication of an electric accident in electric equipments. For that, loads of electric equipment is consisted of incandescent lamps. And the electric accident is simulated a tracking test apparatus according to KS C IEC (Korea Standard C International Electrostatic Commission) 60112 at some part of the simulation of the electric equipment. Simulated electric accident is occurred from static states through discharge in progress, carbon formation to tracking breakdown. The total current of electric equipments is measured and analyzed for detecting of indication of the electric accident using a current monitor. For the result, as an electric accident processed, as a current pulse is bigger and a ratio of appearance also increases at certain part of current waveforms. And standard deviation and probability distribution for certain part of current waveforms show remarkably different pattern in each step of electric accident which is irrespective of amount of load.

Supplementation of Regulation on the Offshore Oil Pipeline for Maintenance (해저 송유배관 유지관리를 위한 기준 보완 제시)

  • Kang, Chan-Seong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.8 no.2
    • /
    • pp.70-81
    • /
    • 2012
  • The study aims to supplement facility management plan and safety regulations & standard of oil pipeline by searching and reviewing related regulation & standard inside and outside of the country. Korean regulation & standard is reviewed based on harbor and fishery design standard of the ministry of maritime affairs and fisheries, general technology standard of oil pipeline safety regulation, gas excavation construction and safety maintenance indicator of Korea gas corporation. Global regulation & standard is reviewed based on U.S standard inspection for offshore pipeline and Europe/Mexico standard inspection for offshore pipeline. The contents of offshore pipeline installation is inserted into pipeline sector for objected facilities of safety inspection regulation & standard and, the standard of safety inspection for offshore pipeline is newly presented into pipeline maintenance part of the planning facilities management with its inspection period and method.

  • PDF

Construction of an International Standard-Based Plant Data Repository Utilizing Web Services Technology (웹 서비스 기술을 활용한 국제 표준 기반의 플랜트 데이터 저장소의 구현)

  • Mun, Du-Hwan;Kim, Byung-Chul
    • IE interfaces
    • /
    • v.23 no.3
    • /
    • pp.213-220
    • /
    • 2010
  • As the market becomes increasingly globalized and competition among companies increases in severity, various specialized organizations are participating across the process plant lifecycle, including the stages of design, construction, operation and maintenance, and dismantlement, in order to ensure efficiency and elevate competitiveness. In this regard, it is an important technical issue to develop services or information systems for sharing process plant data among participating organizations. ISO 15926 is an international standard for integration of lifecycle data for process plants including oil and gas facilities. ISO 15926 Part 7, a part of the ISO 15926 standard, specifies an implementation method called a facade that uses Web Services and ontology technologies for constructing plant data repositories and related services, with the aim of sharing lifecycle data of process plants. This paper discusses the ISO 15926-based prototype facade implemented for storing equipment data of nuclear power plants and servicing the data to interested organizations.

Design of a wavelet adaptive filter for removal of the baseline wandering (기저선 변동 제거를 위한Wwavelet Adaptive Filter의 설계)

  • 박광리;이경중;윤형로
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.80-88
    • /
    • 1997
  • This paper describes a design of a Wavelet Adaptive Filter(WAF) for the removal of the baseline wandering and the minimization of the signal distortion using by wavelet transform and adaptive filter in the ECG signal. WAF consists of two parts. The first part is wavelet transform that decomposes the ECG signal into seven frequency bands using Vaidyanathan and Hoang wavelet. The second part is adaptive filter that uses the signal of seventh low frequency band among the wavelet transformed signals as primary input and a unit impulse sequence as reference input. For the evaluation of the performance of WAF, we used several baseline wandering elimination filters such as commerical standard filter with cutoff frequency of 0.5Hz and general adaptive filter. We made use of MIT/BIH database and real patient data for the evaluation. In conclusion, WAF showed a lower ST segement distortion than standard filter and adaptive filter and has a higher eliminated noise power than standard filter and adaptive filter.

  • PDF

Development of Integrated Product Information Model Using STEP (STEP 을 이용한 통합제품정보모델(IPIM) 개발)

  • Suh, Hyo-Won;Yoo, Sang-Bong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.21 no.3
    • /
    • pp.441-461
    • /
    • 1995
  • This research proposes an Integrated Product Information Model (IPIM) using STEP (Standard for the Exchange of product model data) for Computer Integrated Manufacturing (CIM) of Concurrent Engineering (CE). IPIM is based on Geometry and Topology (STEP Part 42), Form Feature (STEP Part 48), and Tolerance (STEP Part 48) for representing the integrated information of mechanical parts. For the IPIM, 1) new entities are developed for integration of existing entities, and 2) the existing entities are restructured and modified for a special application protocol. In CIM or CE, the advantages of using IPIM having integrated form of geometry, feature and tolerance are 1) integration of product design, process design and manufacturing sequentially or concurrently. 2) keep the product data consistency, modified by different domain, and 3) automatic data exchange between different application software and different hardware. The prototype system is composed of CAD, Data Probe, DBMS and SDAI (Standard Data Access Interface), and the generated STEP data is stored in a step file of DBMS for other applications.

  • PDF

Protective System from Medical Needle-sticks. Part II: Evaluation of Woven Structures and Bifid Needles

  • Seyam, Abdelfattah M.;Turner, LaDawnya C.;Banks-Lee, Pamela
    • Fibers and Polymers
    • /
    • v.4 no.3
    • /
    • pp.129-134
    • /
    • 2003
  • We have shown in Part I [1] of this study that medical needle-stick injuries are causing serious health problems to healthcare personnel and other professionals that require the attention of healthcare and textile researchers to develop new protective systems. Responding to such need, a needle force measurement device that is capable of measuring dynamic forces experienced by medical needles during needle penetration through protective articles was developed and described in part I. This paper reports the results of evaluation of protective woven fabrics from high performance fibers and standard and bifid medical needles using the force measurement system. The woven fabrics varied in cover factor, number of layers, and orientation angle. Standard and bifid needles with different gap widths were used to evaluate the resistance of the fabric to needle penetration.

MPEG-U part 2 based Advanced User Interaction Interface System (MPEG-U part 2 기반 향상된 사용자 상호작용 인터페이스 시스템)

  • Han, Gukhee;Baek, A-Ram;Choi, Haechul
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.54-62
    • /
    • 2012
  • AUI(Advanced User Interaction) interface aims to enhance interaction between various input/output devices and scene descriptions represented by video, audio, and graphic. Recently, MPEG-U part 2 standardization for the AUI interface is under development by MPEG(moving picture experts group). This paper introduces MPEG-U part 2 standard and presents MPEG-U part 2 AUI interface system. The AUI interface system consists of user interface in/output modules and MPEG-U XML generation/interpretation modules. The former and the latter are for UID data handling and XML data processing, respectively. This system MPEG-U standards-based input/output devices and to improve the interaction with the user can be used as a framework. By implementation of the proposed AUI interface system, MPEG-U usage scenario is introduced and it is verified that the AUI interface system conforms to MPEG-U standard.

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.